60
Bell
fi res
English
Installation instructions
3
FAULTS
3.1
POSSIBLE REASONS
Possible reasons for the gas fi re going out are:
• The concentric fl ue system is not installed according to one of the methods detailed
in Paragraph 1.6.
• An incorrect “fl ue gas restriction plate” is fi tted.
• The pilot light extinguishes if fumes are not exhausted or are insuffi ciently
exhausted.
• The pilot light is either dirty or defective.
• Insuffi cient gas pressure.
• (Internal) leak of the concentric fl ue system.
• Thermocouple voltage is too low. This is usually caused by insuffi cient heating of the
thermocouple by the pilot light.
• Dirty electrical contacts in the thermo-electrical system; for example, the
thermocouple connection.
• Batteries in receiver or remote control are fl at.
3.2
SAFETY MEASURES IN THE APPLIANCE
3.2.1 Thermo-electric pilot light shut off
The appliance is protected by means of a thermo-electric pilot light shut off in the event
of a gas escape from the main burner.
3.2.2 Over pressure safety system
The appliance is fi tted with a patented safety system, whereby the door will extract any
over-pressure that arises in a controlled way. In this, a spring system briefl y causes the
door to hinge forward a few centimetres. A loud noise can occur.
A safety strip limits the maximum degree to which the door can be tilted.
If an over-pressure situation occurs, the appliance should be thoroughly checked by the
installer.
Содержание RDL3 CF
Страница 2: ......
Страница 6: ...6 Bell res English Installation instructions...
Страница 64: ...64 Bell res English Installation instructions 6 DIMENSIONS 6 1 ROOM DIVIDER LARGE 3 Without Frame...
Страница 66: ...66 Bell res English Installation instructions 6 3 ROOM DIVIDER LARGE 3 Hidden Door 10 cm Frame...
Страница 68: ...68 Bell res English Installation instructions 6 5 ROOM DIVIDER LARGE LEFT 3 Without Frame...
Страница 70: ...70 Bell res English Installation instructions 6 7 ROOM DIVIDER LARGE LEFT 3 Hidden Door 10 cm Frame...
Страница 71: ...71 Bell res English Installation instructions 6 8 ROOM DIVIDER LARGE RIGHT 3 Without Frame...
Страница 73: ...73 Bell res English Installation instructions 6 10 ROOM DIVIDER LARGE RIGHT 3 Hidden Door 10 cm Frame...
Страница 74: ...74 Bell res English Installation instructions 6 11 OPERATING UNIT...
Страница 83: ...83 Bell res English Installation instructions...
Страница 84: ...01 010216 341766 Your Bell res dealer...