Installation instructions
1.7.2
Connecting the concentric fl ue
Assemble the concentric fl ue system according to one of the examples in section 1.6.1,
fi gure 4 to 14 inclusive.
Make sure that all connections are completely gas tight.
1.7.2.1 Mounting the convection package (option)
The convection package (option) consists of a convection casing and a convection set.
The convection set is supplied separately and consists of two fl exible aluminium
pipes, hose clamps and two built-in convection grills (fi tting box and grill).
Mount the aluminium pipes on the collar adaptors of the convection top plate.
Use the supplied hose clamps. The fl exible aluminium pipes are stretchable to a length
of + 3 meter.