background image

60

Bell

fi res

English

Instructions for use and installation instructions 

The following restriction plates are supplied:

• 

Horizon Bell XXL

• 

Horizon Bell XL

• 

Horizon Bell Large

• 

Horizon Bell Large Tunnel

• 

Corner Bell Large L/R

• 

View Bell Large

• 

View Bell Room Divider Large

B

Restriction plate:
1: Width: B = 40 mm
2: Width: B = 65 mm
3: Width: B = 80 mm

3.5.7   Checking the appliance following installation

After installation, visually check the gas fl ame. When the fi re is ignited, the fl ames 
should be short and blue/yellow in colour. These fl ames should gradually increase in 
height and become more yellow. When all fl ames are yellow, the gas fi re has reached 
the correct temperature.

THE GAS FIRE IS NOW READY FOR USE

Содержание CORNER BELL LARGE L/R

Страница 1: ...NER BELL LARGE L R VIEW BELL LARGE VIEW BELL ROOM DIVIDER LARGE Gas fires with closed combustion system Bellfires wishes you many cosy evenings with your new Bellfires gas fire This document is an ess...

Страница 2: ......

Страница 3: ...GAS FIRES WITH CLOSED COMBUSTION SYSTEM Horizon Bell series Horizon Bell XXL HBXXL Horizon Bell XL HBXL Horizon Bell Large HBL Horizon Bell Large Tunnel HBLT Corner Bell series Corner Bell Large L R C...

Страница 4: ...4 Bellfires English Instructions for use and installation instructions...

Страница 5: ...ons CONTENTS Page 1 WARRANTY TERMS 7 2 INSTRUCTIONS FOR USE 9 3 INSTALLATION INSTRUCTIONS 22 4 MAINTENANCE 61 5 FAULTS 62 6 ELECTRICAL DIAGRAM 63 7 DIMENSIONS 64 8 TECHNICAL DETAILS REGULATIONS 71 9 R...

Страница 6: ...6 Bellfires English Instructions for use and installation instructions...

Страница 7: ...llowing aspects are not covered under the terms of the warranty defects arising which are attributable in whole or in part to a Not paying due heed to installation operating and maintenance instructio...

Страница 8: ...8 Bellfires English Instructions for use and installation instructions...

Страница 9: ...can burn at all times freely over the main burner Only in this way is proper ignition of the main burner ensured Ignoring these directions could lead to a dangerous situation It is essential that the...

Страница 10: ...he bottom of the front of your gas fire or outside the gas fire in a special box supplied If the control knob is fitted to the front of the gas fire the gas fire frame must be removed to access the kn...

Страница 11: ...e desired setting Important When the main burner is switched on by turning the motor knob to the left the burner must ignite within 10 seconds If this does not happen immediately close the gas tap and...

Страница 12: ...en this will release the catch and the door will spring out or The receiver and the gas control block are behind the operating flap at the bottom of the appliance Pull the flap forward to open The han...

Страница 13: ...ress large flame to set the hour and small flame to set the minute Wait or press OFF to return to mode Important Setting up signal code before using the appliance for the first time Before the applian...

Страница 14: ...sible to use the remote control in 3 ways to operate the appliance 1 2 and 3 You can cycle through the menu with operating possibilities by repeatedly depressing the SET button At the selected startin...

Страница 15: ...rmostat Appliance is in the stand by position and the pilot light is burning Automatic temperature regulation of the pre set night temperature The room temperature is measured and compared with the pr...

Страница 16: ...the first heating period Press SET again to set the second heating period P2 heat ON and P2 heat OFF Wait a moment or press OFF to switch back to mode 2 5 3 Operation Remote Control Igniting the fire...

Страница 17: ...witch is not in the I position 5 short beeps Ignition of the pilot light and main burner failed Possible cause air in the pilot light pipe Important If the pilot flame goes out then wait for at least...

Страница 18: ...f the pilot flame goes out for any reason wait for 5 minutes before attempting to re light it Faults If the signals from the hand held transmitter do not seem to be reaching the receiver the cause may...

Страница 19: ...erted incorrectly the electronics or drive may be irreparably damaged Only replace the batteries when the appliance has been completely switched off Figure 5 Gas regulating block Operating Knob in MAN...

Страница 20: ...east 5 minutes before repeating the above procedure Move the operating knob to the ON position Depending on the position of the motor knob the burner will either ignite or not By turning the motor kno...

Страница 21: ...convection system of the appliance could lead to discoloration of the walls and ceiling It is therefore very important to ensure that the room in which the appliance is located is sufficiently ventil...

Страница 22: ...usted naturally to the outside environment through the inner 100 mm pipe whereas the combustion air supply passes between the 100 mm and 150 mm pipes The wall connection must be carried out using the...

Страница 23: ...should be cleaned by an expert 3 2 BARBAS CONCENTRIC FLUE SYSTEM 100 MM 150 MM AND 130 MM 200 MM The gas fire in combination with the Barbas concentric flue system 100 mm 150 mm and or 130 mm 200 mm...

Страница 24: ...ing the outlet for correct operation Roof mounted outlet Figure 6 Roof mounted outlet This must be positioned at least 0 5 m from the roof edge the apex of the roof can be disregarded Wall mounted out...

Страница 25: ...opening serving an occupied room a toilet or a bathroom B A heating air supply when the supply flows through an occupied room C A window that can be opened and that is near an occupied room a toilet...

Страница 26: ...o a facing wall 2 m if the distance from the facing wall is less the criteria detailed for On a wall general apply Enquire at your local gas company for the regulations relating to outlets positioned...

Страница 27: ...erature of the outer walls approx 150 C no flammable materials may be located or used in the vicinity of the flue system The complete flue system must therefore be sleeved with a heat resistant materi...

Страница 28: ...Bell Large Horizon Bell Large Tunnel Corner Bell Large L R View Bell Large 4 0 12 0 m Width B 80 mm View Bell Room Divider Large 18 10 11 12 13 1 4 Y 28 16 17 16 24 23 24 23 100 Figure 9 Vertical roof...

Страница 29: ...te Horizon Bell XXL Horizon Bell XL Horizon Bell Large Horizon Bell Large Tunnel 1 0 11 0 m 0 3 0 m 1 0 11 0 m Width B 40 mm Corner Bell Large L R View Bell Large View Bell Room Divider Large Y1 Y2 X...

Страница 30: ...x restriction plate Horizon Bell XXL Horizon Bell XL 2 0 4 0 m Width B 65 mm Horizon Bell Large Horizon Bell Large Tunnel Corner Bell Large L R View Bell Large 4 0 12 0 m Width B 80 mm View Bell Room...

Страница 31: ...7 29 26 25 23 28 4 1 100 Appliance Distance Y1 Distance X Distance Y1 Y2 Y3 Assemble min max min max min max restriction plate Horizon Bell XXL Horizon Bell XL Horizon Bell Large Horizon Bell Large Tu...

Страница 32: ...nce Y Assemble min max restriction plate Horizon Bell XXL Horizon Bell XL 2 0 4 0 m Width B 65 mm Horizon Bell Large Horizon Bell Large Tunnel Corner Bell Large L R View Bell Large 4 0 12 0 m Width B...

Страница 33: ...4 1 100 Appliance Distance Y1 Distance X Distance Y1 Y2 Y3 Assemble min max min max min max restriction plate Horizon Bell XXL Horizon Bell XL Horizon Bell Large Horizon Bell Large Tunnel 1 0 11 0 m 0...

Страница 34: ...m Appliance Distance Y Distance X Assemble min max min max restriction plate Horizon Bell Large 2 0 3 0 m 0 0 6 m Horizon Bell Large Tunnel Corner Bell Large L R View Bell Large 3 0 4 0 m 0 1 6 m View...

Страница 35: ...1 113 0 16 m Appliance Distance Y Distance X Assemble min max min max restriction plate Horizon Bell Large Horizon Bell Large Tunnel 1 0 2 0 m 0 0 6 m Corner Bell Large L R View Bell Large View Bell R...

Страница 36: ...istance X Assemble min max min max restriction plate Horizon Bell Large Horizon Bell Large Tunnel Corner Bell Large L R 1 0 3 0 m 0 4 6 m View Bell Large View Bell Room Divider Large 100 4 128 1 Y X 1...

Страница 37: ...ction plate Horizon Bell XXL 0 5 1 0 m 0 2 6 m Horizon Bell XL Horizon Bell Large 1 0 3 0 m 0 3 6 m Width B 40 mm Horizon Bell Large Tunnel Corner Bell Large L R 1 0 3 0 m 3 6 8 6 m View Bell Large Vi...

Страница 38: ...all spacer plates Stainless steel locking band 150 mm quick fastening Silicone seal 150 mm Wall strap Set of ceiling finishing plates fire stops ART ORDER NO 302289 302290 302291 302292 302297 302298...

Страница 39: ...m Minimum 2 per connection Hose clamp 150 mm Minimum 2 per connection Vertical roof termination kit L 610 mm vertical incl and For the flexible flue system Concentric T piece with gauging orifice incl...

Страница 40: ...ainless steel locking band 200 mm quick fastening Silicone seal 200 mm Wall strap Set of ceiling finishing plates fire stops Stainless steel adapter piece 130 from fire to flexible 130 mm external rig...

Страница 41: ...control block and receiver this will be located once it has been built in at a maximum of 50 cm from the left or right hand side of the appliance 3 4 5 Convection package connections When fitting a c...

Страница 42: ...e Only the top and sides may be fitted with a strip of white loose insulation wool heat resistant to 1000 C width 15 cm max to protect the wall Do not use fibreglass or Rockwool or any other sort of i...

Страница 43: ...iance against the wall and ensure that it is level The appliance may not be installed against a flammable rear wall Attach the appliance to the wall with 2 wedge bolts Use the adjustable mounting brac...

Страница 44: ...as remote control the piezo cable the 8 terminal cable and the two thermocouple cables must be connected to the receiver see figure 22 and Chapter 6 Electrical Diagram Frame with door white Operating...

Страница 45: ...urn using a fork spanner See figure 22 23 and Chapter 6 Remote control Gas regulating block and receiver in operating unit Figure 22 Remote control Gas regulating block and receiver in operating unit...

Страница 46: ...g block must be fitted Figure 23 Gas regulating block Remote control Side inlet Side outlet Bottom Outlet Bottom Inlet Inlet Pressure Tap Outlet Pressure Tap Thermo Unit Connection Minimum Rate Adjust...

Страница 47: ...control Gas regulating block in operating unit The photo below shows how the piping for a hand control gas regulating block must be fitted Motor knob Microswitch Operating Knob Remote control Hand con...

Страница 48: ...ating unit to the appliance through an easily accessible hollow cavity or a heat resistant pipe of minimum 50 mm During subsequent installation of the operating unit protect the gas regulating block a...

Страница 49: ...The appliance can be supplied with Ceramic log set embers Marble pebbles white small white marble stones Marble pebbles grey small grey marble stones Important Carefully place the chips of wood embers...

Страница 50: ...their residue should not be scattered on the burner This can cause a blockage on the burner orifices Embers and vermiculite granules must not be placed next to the pilot light burner Important make su...

Страница 51: ...51 Bellfires English Instructions for use and installation instructions Logs Log no Log no Log no Log no Log no Log no Log no Log no...

Страница 52: ...t be placed next to the pilot light burner Keep the burner orifices unblocked Keep the burner orifices unblocked Figure 25 Log set Horizon Bell XXL Natural gas and propane Embers must not be placed ne...

Страница 53: ...re 27 Log set Horizon Bell Large Corner Bell Large L R View Bell Large Natural gas and propane Figure 28 Log set Horizon Bell Large Tunnel Natural gas and propane Keep the burner orifices unblocked Em...

Страница 54: ...e and installation instructions Keep the burner orifices unblocked Figure 29 Log set View Bell Room Divider Large Natural gas Embers must not be placed next to the pilot light burner Embers must not b...

Страница 55: ...use and installation instructions Figure 30 Log set View Bell Room Divider Large Propane Keep the burner orifices unblocked Embers must not be placed next to the pilot light burner Embers must not be...

Страница 56: ...d the burner Make sure that the pilot light remains free Horizon Bell XXL see figure 32 Horizon Bell XL see figure 33 Horizon Bell Large see figure 34 Corner Bell Large L R see figure 34 View Bell Lar...

Страница 57: ...ocked Figure 33 Marble pebbles Horizon Bell XL Natural gas and propane Keep the burner orifices unblocked Figure 32 Marble pebbles Horizon Bell XXL Natural gas and propane Marble pebbles must not be p...

Страница 58: ...ell Large Tunnel Natural gas and propane Figure 34 Marble pebbles Horizon Bell Large Corner Bell Large L R View Bell Large View Bell Room Divider Large Natural gas and propane Keep the burner orifices...

Страница 59: ...fit the frame until the wall has been finished Use the protective items supplied gloves or cloth Do not use masking tape 3 5 6 Mounting flue gas restriction plate Depending on the length and shape of...

Страница 60: ...oom Divider Large B Restriction plate 1 Width B 40 mm 2 Width B 65 mm 3 Width B 80 mm 3 5 7 Checking the appliance following installation After installation visually check the gas flame When the fire...

Страница 61: ...ter cleaning Carefully replace the embers vermiculite granules logs set or pebbles on and around the main burner according to the installation directions in this instruction booklet Do not place any e...

Страница 62: ...restriction plate is fitted The pilot light extinguishes if fumes are not exhausted or are insufficiently exhausted The pilot light is either dirty or defective Insufficient gas pressure Thermocouple...

Страница 63: ...ouple Ignition cable Antenna O I Switch RECEIVER Battery Compartment panel 4 AA Batteries cable 2 cable 1 red black SPARK SPARK SW TC SW TC GR SW MA MO Pilot ON OFF Switch Thermocurrent interrupter Bl...

Страница 64: ...instructions 7 1 HORIZON BELL XXL 7 1 1 HORIZON BELL XXL Hidden door 7 DIMENSIONS Available with control unit in appliance bottom or in separate operating unit see page 70 Control unit in separate op...

Страница 65: ...65 Bellfires English Instructions for use and installation instructions 7 2 HORIZON BELL XL 7 2 1 HORIZON BELL XL Hidden door 7 3 HORIZON BELL LARGE 7 3 1 HORIZON BELL LARGE Hidden door...

Страница 66: ...66 Bellfires English Instructions for use and installation instructions 7 3 2 HORIZON BELL LARGE Frame 9 cm 7 3 3 HORIZON BELL LARGE Frame Roderick Vos...

Страница 67: ...67 Bellfires English Instructions for use and installation instructions 7 4 HORIZON BELL LARGE TUNNEL 7 4 1 HORIZON BELL LARGE TUNNEL Hidden door 7 4 2 HORIZON BELL LARGE TUNNEL Frame 9 cm...

Страница 68: ...llfires English Instructions for use and installation instructions 7 4 3 HORIZON BELL LARGE TUNNEL 1x Hidden door and 1x Frame 9 cm 7 4 4 HORIZON BELL LARGE TUNNEL 1x Hidden door and 1x Frame Roderick...

Страница 69: ...69 Bellfires English Instructions for use and installation instructions 7 5 CORNER BELL LARGE R Hidden door 7 6 VIEW BELL LARGE Hidden door...

Страница 70: ...70 Bellfires English Instructions for use and installation instructions 7 7 VIEW BELL ROOM DIVIDER LARGE Hidden door OPERATING UNIT...

Страница 71: ...er pressure max Cold 10 3 mbar 29 0 mbar Burner pressure min 3 5 mbar 5 0 mbar Gas regulator block hand control BM 733 234484 BM 733 234484 Gas regulator block remote control Mertik GV 34 GV 60 Mertik...

Страница 72: ...and control BM 733 234484 BM 733 234484 Gas regulator block remote control Mertik GV 34 GV 60 Mertik GV 34 GV 60 Main burner IGP 1350x140 mm Natural gas IGP 1350x140 mm Butane Propane Primary air inle...

Страница 73: ...Gas regulator block hand control BM 733 234484 BM 733 234484 Gas regulator block remote control Mertik GV 34 GV 60 Mertik GV 34 GV 60 Main burner IGP 1022x140 mm Natural gas IGP 1022x140 mm Butane Pro...

Страница 74: ...burner injector butane propane no 380 HBXXL HBXL 11 310995 Gas regulator block BM 733 234484 M9 Thermocouple connection 12 301983 Nut 4 mm BM for pilot light pipe 13 301989 Olive 4 mm BM for pilot li...

Страница 75: ...ner pipe 8 mm L 1500 mm Flexible Stainless steel 10 kW 45 326053 Pilot light pipe 4 mm L 2000 mm Flexible Stainless steel HBXXL 46 325949 Burner pipe 8 mm L 2000 mm Flexible Stainless steel HBXXL 47 3...

Страница 76: ...l Large View Bell Room Divider Large Horizon Bell Large Tunnel Chips of Embers with Vermiculite no 4 wood set Glow effect black Anthracite filtered 1 xxxxxx 2x 2x 1x 1x 1x 1x 1x 2 xxxxxx 2x 2x 1x 1x 1...

Страница 77: ...g This can include Cardboard Wood Plastic Paper Such materials must be disposed of responsibly in line with local regulations Batteries should be disposed of as chemical waste Batteries must be dispos...

Страница 78: ...02 010809 324981 INTERFOCOS B V HALLENSTRAAT 17 5531 AB BLADEL NEDERLAND E mail info interfocos nl Internet www interfocos com...

Отзывы: