background image

View Bell Medium 3 CF 

Direct Vent Gas Fireplace

Installation manual

 

-  Do not store or use gasoline or other fl ammable vapors and liquids in   

 

 

the vicinity of this or any other appliance.

 

-   WHAT TO DO IF YOU SMELL GAS:

 

 

•   Do not try to light any appliance.

 

 

•   Do not touch any electrical switch; do not use any phone in your    

 

 

    building.

 

 

•   Immediately call your gas supplier from a neighbor’s phone.  

 

 

    Follow the gas supplier’s instructions.

 

 

•   If you cannot reach your gas supplier, call the fi re department.

 

-  Installation and service must be performed by a qualifi ed installer, 

 

 

service agency or the gas supplier.

 

WARNING:

 If the information in these instructions are not 

 

followed exactly, a fi re or explosion may result causing property damage,  

 

personal injury or loss of life.

 

This appliance may be installed in an aftermarket, permanently located,   

 

manufactured home (USA only) or mobile home, where not prohibited by 

 

local codes. This appliance is only for use with the types of gas indicated 

 

on the rating plate. A conversion kit is supplied with the appliance.

WARNINGS

 

INSTALLER: 

 

Leave this manual with  

 

 

the appliance.

 

CONSUMER: 

 

Retain this manual for 

 

future reference.

A barrier designed to reduce the risk of burns from the 
hot viewing glass is provided with this appliance and 
shall be installed for the protection of children and other 
at-risk individuals.

HOT GLASS 

WILL 

CAUSE BURNS.

 

DO NOT TOUCH 

GLASS

UNTIL COOLED.

NEVER 

ALLOW CHILDREN

TO TOUCH GLASS.

WARNING

Содержание Corner Bell Large 3 L/R CF

Страница 1: ...n these instructions are not followed exactly a fire or explosion may result causing property damage personal injury or loss of life This appliance may be installed in an aftermarket permanently located manufactured home USA only or mobile home where not prohibited by local codes This appliance is only for use with the types of gas indicated on the rating plate A conversion kit is supplied with the...

Страница 2: ......

Страница 3: ...AS LINE INSTALLATION 41 BUILDING IN THE APPLIANCE 46 PLACING OF CERAMIC LOG SET 50 GAS FIRE DECORATION KITS 54 MOUNTING OF FLUE GAS RESTRICTION PLATE 58 CHECK OVERPRESSURE HATCHES 59 VISUAL CHECK OF GAS FLAMES 60 ANNUAL MAINTENANCE 61 FAULTS 62 POSSIBLE REASONS 62 SAFETY MEASURES IN THE APPLIANCE 62 DISMANTLING ASSEMBLING OF THE GLASS 63 DIAGRAM ELECTRICITY AND GAS 68 DIMENSIONS 69 OPERATING UNIT ...

Страница 4: ...4 Bellfires Installation instructions ...

Страница 5: ...ll be replaced with the manufacturer s barrier for this appliance 4 Any safety screen guard or barrier removed for servicing the appliance must be replaced prior to operating the appliance 5 Children and adults should be alerted to the hazards of high surface temperature and should stay away to avoid burns or clothing ignition 6 Young children MUST be carefully supervised when they are in the same...

Страница 6: ...the glass when it is hot 17 DO NOT strike or slam the glass panel 18 DO NOT modify the appliance under any circumstances Any parts removed for servicing must be replaced prior to operating the appliance 19 Turn the appliance off and let cool before servicing installing or repairing ONLY a qualified service person should install service or repair the appliance Have burner system inspected annually b...

Страница 7: ...ny gas control which has been submerged in water 25 DO NOT operate the appliance if any log is broken 26 The installation must conform with local codes or in the absence of local codes with the National Fuel Gas Code ANSI Z223 1 NFPA 54 or the Natural Gas and Propane Installation Code CSA B149 1 27 This appliance when installed must be electrically grounded in accordance with local codes or in the...

Страница 8: ...dium 3 CF tested to ANSI Z21 88 2009 CSA 2 33 2009 Vented Gas Fireplace Heaters ANSI Z21 88a 2012 CSA 2 33a 2012 Addenda 1 to ANSI Z21 88 2009 CSA 2 33 2009 CSA P4 1 09 Testing method for measuring annual fireplace efficiency Canada A manufactured home USA only or mobile home OEM installation must conform with the Manufactured Home Construction and Safety Standard Title 24 CFR Part 3280 or when such...

Страница 9: ...consumption The appliance will be delivered from the factory with a 5 x 7 concentric connection for extracting the flue gases and supply of combustion air It is possible to install the appliance with either a wall or roof outlet The roof connection must be carried out using a Bellfires adapter 5 x 7 to 5 x 8 together with a reducer 5 x 8 to 4 x 6 or using a Bellfires adapter 5 x 7 to 4 x 6 and the co...

Страница 10: ...d 5 x 8 METAL FAB Sure Seal Direct Vent Products 4 x 6 5 and 5 x 8 The appliance in combination with the concentric flue system 4 x 6 and or 5 x 8 rigid and or flexible for the brands M G DuraVent Direct Vent Pro Selkirk Direct Temp or Metal Fab Sure Seal has been approved in accordance with the ANSI CSA standard for direct vented gas appliances and may therefore be used only with these systems The ...

Страница 11: ... of high adjustable feet 4 pieces adapter pieces Feet height max 13 in 334765 Mantle iron VWBM3 337810 High altitude kit 2 000 4 500 ft View Bell Medium 3 CF Natural gas and Propane gas M G DuraVent Direct Vent Pro concentric flue system See component summary SELKIRK DIRECT TEMP Direct Vent Products concentric flue system See component summary METAL FAB Sure Seal Direct Vent Products concentric flue ...

Страница 12: ...of the gas supplier Never use combustible materials during the installation During installation of the appliance a clearance of 0 12 in 3 mm should be maintained on all sides of the appliance to allow for expansion of the appliance during operation Do not insulate the appliance Only the top and sides may be fitted with a strip of white loose insulation wool heat resistant to 1832 F 1000 C width 5 9...

Страница 13: ...in 1 2 54 cm between the appliance and the rear wall and the side wall according to figure 1 Minimum clearances to combustible material must be maintained See also figure 13 and 14 Clearance to combustible ceiling Place a non combustible insulation plate false ceiling with a thickness of min 1 3 cm at a height of minimum 20 50 cm above the appliance Maintain a free space of 4 10 cm between the insul...

Страница 14: ...all at least 12 mm thick between the appliance and a non combustible rear and side wall Maintain a free space of at least 2 cm on either side of the insulation plate Minimum clearances as shown in figure 2 must be maintained See also figure 13 and 14 Figure 2 Clearances to non combustible material Non combustible material Appliance Insulation board ...

Страница 15: ...ling to prevent discoloration Also an open distance between the fireplace chimney breast and the ceiling of 2 5 cm over a minimal width of 23 60 cm is sufficient Is also total 46 sq ins 300 cm2 Non combustible insulation plate board Any used insulation plates must have a maximum thermal conductivity of 0 69 BTU ft2 h F in 0 10 W m K Suitable insulation materials are listed in table 1 Do not use fibre...

Страница 16: ...arances are shown in figure 3 to 5 Figure 3 Mantel clearances 12 Max depth 2 Min 2 Max depth 12 Min from opening 4 Min to combustible 2 Min from opening Ceiling Minimum 20 from opening or place a non combustible hearth floor stone with a depth of minimal 12 in 30 cm in front of the full width of the glass Non combustible Insulation plate board Combustible mantel piece Non combustible Insulation plat...

Страница 17: ...instructions CLEARANCES Figure 4 Top mantel clearances Depth of mantel inch Heigth of mantel inch Non combustible material Insulation plate board Glass front appliance Top of fireplace opening Side view Combustible mantel piece ...

Страница 18: ...clearances CLEARANCES Width of mantel inch Depth of mantel inch Width of mantel inch Side of fireplace opening Top view Side of fireplace opening Non combustible material Insulation plate board Depth of mantel inch Combustible mantel piece Combustible mantel piece ...

Страница 19: ... 30 cm Minimum safe distance 40 1 0 m to flammable materials such as curtains furniture etc in front of the fireplace Install a non combustible hearth floor stone when the underside of the glass is less then 4 10 cm above a combustible floor The hearth must have a depth of minimal 12 30 cm in front of the whole width of the glass The height of the hearth must be minimal 1 12 30 cm 12 30 cm CLEARANCES ...

Страница 20: ...r balcony 12 in 30 cm 12 in 30 cm B Clearance to window or door that may be opened 12 in 30 cm 9 in 23 cm C Clearance to permanently closed window 12 in 30 cm 9 in 23 cm D Vertical clearance to ventilated soffit located above the terminal within a 18 in 46 cm 18 in 46 cm horizontal distance of 2 feet 610 mm from the center line of the terminal ...

Страница 21: ...ppliance K Clearance to a mechanical air supply inlet 6 ft 1 83 m 3 ft 91 cm above if within 10 ft 3 m horizontally L Clearance above paved sidewalk or paved driveway located on public property 7 ft 2 13 m 7 ft 2 13 m M Clearance under veranda porch deck or balcony 20 in 51 cm 20 in 51 cm 1 In accordance with the current CSA B149 Installation Codes 2 In accordance with the current ANSI Z223 1 NFPA...

Страница 22: ... 24 Pipe Length 46DVA 24 11 36 Pipe Length 46DVA 36 12 48 Pipe Length 46DVA 48 13 60 Pipe Length 46DVA 60 14 8 Pipe Extension 46DVA 08A 15 16 Pipe Extension 46DVA 16A 16 11 17 Adjustable Pipe 46DVA 17TA 17 17 24 Adjustable Pipe 46DVA 24TA 18 30 Elbow 46DVA E30 19 45 Elbow 46DVA E45 20 60 Elbow 46DVA E60 21 90 Elbow 46DVA E90 22 Elbow Strap 46DVA ES 23 Wall Strap 46DVA WS 24 Ceiling Support Wall Th...

Страница 23: ...60 Pipe Length 58DVA 60 114 8 Pipe Extension 58DVA 08A 115 16 Pipe Extension 58DVA 16A 116 11 17 Adjustable Pipe 58DVA 17TA 117 17 24 Adjustable Pipe 58DVA 24TA 118 30 Elbow 58DVA E30 119 45 Elbow 58DVA E45 120 60 Elbow 58DVA E60 121 90 Elbow 58DVA E90 122 Elbow Strap 58DVA ES 123 Wall Strap 58DVA WS 124 Ceiling Support Wall Thimble Cover 58DVA DC 125 Cathedral Ceiling Support Box 58DVA CS 126 Cei...

Страница 24: ... 6 Pipe 4DT 06 7 DT 9 Pipe 4DT 09 8 DT 12 Pipe 4DT 12 9 DT 18 Pipe 4DT 18 10 DT 24 Pipe 4DT 24 11 DT 36 Pipe 4DT 36 12 DT 48 Pipe 4DT 48 14 Adjustable Length 4 10 4DT AJ12 16 Telescopic Length 14 22 4DT TL 14 17 Telescopic Length 38 70 4DT TL 38 19 Elbow 45 4DT EL45 21 Elbow 90 4DT EL90S 23 Wall Support Band 4DTWS B 24 Ceiling Support 4DT CS 25 Cathedral Ceiling Support Box 4DT CCS 26 Firestop Spa...

Страница 25: ...Direct Temp 5DT AAB 102 Horizontal Insulated Termina on Square 5DT HC 106 DT 6 Pipe 5DT 06 107 DT 9 Pipe 5DT 09 108 DT 12 Pipe 5DT 12 109 DT 18 Pipe 5DT 18 110 DT 24 Pipe 5DT 24 111 DT 36 Pipe 5DT 36 112 DT 48 Pipe 5DT 48 114 Adjustable Length 4 10 5DT AJ12 119 Elbow 45 5DT EL45 121 Elbow 90 5DT EL90 123 Wall Support Band 5DTWS B 124 Ceiling Support 5DT CS 125 Cathedral Ceiling Support Box 5DT CCS...

Страница 26: ...mina on Termina on Cap 4DVT 6 6 Pipe Straight Length assembly 4D6 8 12 Pipe Straight Length assembly 4D12 9 18 Pipe Straight Length assembly 4D18 10 24 Pipe Straight Length assembly 4D24 11 36 Pipe Straight Length assembly 4D36 12 48 Pipe Straight Length assembly 4D48 14 Adjustable Length 3 10 4DAL 19 Elbow 45 4D45L 21 Elbow 90 4D90L 23 Wall support 4DWS 26 Firestop 4DFS Support Plate 4DSP Decora ...

Страница 27: ...5 x 7 to 5 x 8 Metal Fab 5DBA 102 Horizontal Termina on Square Termina on Cap 5DHT 106 6 Pipe Straight Length assembly 5D6 108 12 Pipe Straight Length assembly 5D12 109 18 Pipe Straight Length assembly 5D18 110 24 Pipe Straight Length assembly 5D24 111 36 Pipe Straight Length assembly 5D36 112 48 Pipe Straight Length assembly 5D48 114 Adjustable Length 3 10 5DAL 119 Elbow 45 5D45L 121 Elbow 90 5D9...

Страница 28: ...be used together in one installation Check whether the wall or roof termination kit to be used exactly matches one of those listed in this installation manual Due to the high temperature of the outer walls approx 300 F 150 C no flammable materials may be located or used in the vicinity of the flue system Clearance to combustible materials Do not insulate the concentric flue For all other installation...

Страница 29: ... operated daily during the winter months This will help to stop the roof termination from freezing up We recommend using the thermostat room temperature setting on the remote to allow the appliance to cycle IMPORTANT Do not use Silicone RTF products as they will create a white residue on the glass When necessary use an alternative direct vent sealing compound for example Mill Pac Sealant There are...

Страница 30: ...ue connection 5 x 7 ALL SIZES INCLUDE THE LENGTH OF THE ROOF OR WALL TERMINATION Assemble restriction plate Appliance Distance Y Concentric connection min max on appliance is 5 x 7 72 144 Width B 65 mm 2 0 4 0 m View Bell Medium 3 144 432 Width B 80 mm 4 0 12 0 m Item descriptions see Vent Installation Page 22 27 2 3 4 5 26 6 to 17 23 28 29 101 140 or 1 6 to 17 2 3 4 5 30 23 Gas appliance ...

Страница 31: ...mble restriction plate Appliance Distance Y1 Distance X Distance Y1 Y2 Concentric connection min max min max min max on appliance is 5 x 7 View Bell 36 396 0 108 36 396 Width B 40 mm Medium 3 1 0 11 0 m 0 3 0 m 1 0 11 0 m Y1 Y2 X 101 140 or 1 23 6 to 17 23 23 18 19 20 21 28 29 2 3 4 5 Gas appliance Item descriptions see Vent Installation Page 22 27 RIGID CONCENTRIC FLUE 4 x 6 SYSTEM CONNECTION POS...

Страница 32: ...ATION FLEXIBLE CONCENTRIC FLUE 4 x 6 SYSTEM CONNECTION POSSIBILITIES Appliance Concentric flue connection 5 x 7 Assemble restriction plate Appliance Distance Y Concentric connection min max on appliance is 5 x 7 72 144 Width B 65 mm 2 0 4 0 m View Bell Medium 3 144 432 Width B 80 mm 4 0 12 0 m Y 101 140 or 1 30 6 to 17 36 36 26 2 3 4 5 Gas appliance 23 34 Item descriptions see Vent Installation Pag...

Страница 33: ...lways at least 2 to 1 Assemble restriction plate Appliance Distance Y1 Distance X Distance Y1 Y2 Y3 Concentric connection min max min max min max on appliance is 5 x 77 8 View Bell 36 396 0 108 36 396 Width B 40 mm Medium 3 1 0 11 0 m 0 3 0 m 1 0 11 0 m Y 2 34 2 3 4 5 Y1 X Gas appliance Y3 101 140 or 1 6 to 17 26 36 23 36 30 Item descriptions see Vent Installation Page 22 27 FLEXIBLE CONCENTRIC FL...

Страница 34: ...18 0 18 View 0 5 1 0 m 0 0 5 m 0 0 5 m 0 0 5 m Bell Medium 3 36 108 0 36 18 72 0 18 1 0 3 0 m 0 1 0 m 0 5 2 0 m 0 0 5 m 36 108 0 108 36 108 0 18 1 0 3 0 m 0 3 0 m 1 0 3 0 m 0 0 5 m Appliance Concentric flue connection 5 x 7 RIGID CONCENTRIC FLUE 5 x 8 SYSTEM CONNECTION POSSIBILITIES and with wall outlet 5 x 8 Gas appliance Y2 Y1 X1 106 to 117 X2 121 121 101 102 to 105 IMPORTANT For propane applianc...

Страница 35: ...Assemble restriction plate Appliance Distance Y Distance X Concentric connection on min max min max appliance is 5 x 7 0 18 0 18 0 0 5 m 0 0 5 m 18 36 0 54 View Bell Medium 3 0 5 1 0 m 0 1 5 m 36 108 0 162 1 0 3 0 m 0 4 5 m 121 Gas appliance Y 101 X 106 to 117 102 to 105 IMPORTANT For propane appliances Always use a minimum of 12 rise 12 pipe length of 5 x 8 on top of the unit first before working ...

Страница 36: ...ant They may also cause discolouring of the column Flammable materials such as curtains should not be placed in the vicinity of the appliance Minimum safe distance 40 100 cm See also chapter CLEARANCES The appliance can be easily installed using a set of carrying brackets accessory After installing remove carrying brackets IMPORTANT The appliance must be constructed on a sufficiently solid floor tha...

Страница 37: ... insulation plate board according to the Chapter CLEARANCES 1 Inlet opening appliance convection air for chimney breast Enclosure 2 Natural convection in the chimney breast Enclosure 3 Outlet opening chimney breast Enclosure convection air Total minimal required 46 in2 300 cm2 4 Concentric flue connection appliance 5 x 7 with an adapter Bellfires 5 x 7 to 5 x 8 See available approved components for ...

Страница 38: ...ng to the Chapter CLEARANCES 1 Inlet opening appliance convection air for chimney breast Enclosure 2 Natural convection in the chimney breast Enclosure 3 Outlet opening chimney breast Enclosure convection air Total minimal required 46 in2 300 cm2 4 Concentric flue connection appliance 5 x 7 with an adapter Bellfires 5 x 7 to 5 x 8 See available approved components then a reducer 5 x 8 to 4 x 6 See a...

Страница 39: ... chamber can be reached after the window and the grill around the burner have been removed see Chapter DISMANTLING ASSEMBLING OF THE GLASS Using an Allen key no 5 the appliance can be adjusted to the required height POSITIONING THE APPLIANCE IMPORTANT Press the 4 protec ng covers back into the floor Adjustable feet seen from the bottom Adjust height with Allenkey no 5 of the appliance Press the 4 p...

Страница 40: ...e installation instructions in chapter CLEARANCES Use only the specified insulation plates Attach the appliance to the rear wall with 2 wedge bolts Use the adjustable mounting brackets at the side of the appliance for this 2x Mounting bracket WARNING Connection of the appliance to gas supply must be performed by a qualified installer service agency or the gas supplier Follow the local codes IMPORTAN...

Страница 41: ...asement by cement etc Note When the installation of the built in operating unit is not possible one can place the gas regulator block and receiver under the appliance Important Keep a minimal distance of 4 10 cm between the gas regulator block receiver and the bottom of the appliance Attach the gas regulator block fixed to the wall floor Gas regulator block and receiver must always be accessible for...

Страница 42: ...d to gas leaks IMPORTANT Screw the thermocouple connection and thermocouple interrupter manually into the gas regulator block Afterwards carefully fasten a half turn with a spanner Disassembly and assembly of pipes and cables If necessary for mounting all pipe compression fittings and cable connectors can be temporarily disassembled After mounting carefully reassemble all pipes and cables Check aft...

Страница 43: ...NPT Gas regulator block Thermocouple Pilot light pipe Ø4 mm Flex Thermocouple interrupter Figure 16 Gas regulator block and gas valve Gas and thermocouple connections Figure 17 Gas regulator block Front Pilot Gas Adjustment Screw Pierce the housing with a small screwdriver Adjustment Screw Maximum Burner pressure Motor knob Microswitch 8 Wire connecting cable receiver ...

Страница 44: ...ion Adjustment Screw Minimum Burner pressure Pilot light connection Figure 18 Gas regulator block Rear Figure 19 Receiver Top Thermocouple voltage current OUT connection yellow Piezo cable connection RESET button AUX Electrical connection for gas valve rear burner TC SW Thermocouple voltage current IN connection red 6 VDC Adapter connection option Connection 8 wire cable gas regulator block Connec...

Страница 45: ...45 Bellfires Installation instructions GAS LINE INSTALLATION Figure 20 Receiver AUX connection RESET button RESET button AUX Electrical connection for gas valve rear burner ...

Страница 46: ...penings grids above the fireplace The brickwork must be built up around the appliance In connection with the appliance expanding during burning there must be at least 0 12 3 mm clearance on either side of the appliance Do not build up the brickwork farther than the angle irons brackets keep in mind the thickness of any plastering IMPORTANT Do not use masking tape on the appliance when installing an...

Страница 47: ...t fall forwards Mantle iron option The optional mantle iron is intended for supporting the brickwork above the appliance The mantle iron must rest on the brickwork on both sides so that upward building is possible Level the mantle iron with the supplied bar set Keep a clearance of 0 1 2 mm between the mantle iron and the top of the side panels The brickwork plating must never rest directly on the ...

Страница 48: ...that the height between the mantle Keep a clearance of 0 1 2 mm between iron and the underside of the glass is the the mantle iron and the top of the side same at left middle and right panels The side panels should always be easily removable Check that the mantle iron is at right angles to the side panels both left and right Put ceramic felt on the top of the mantle iron before laying bricks or us...

Страница 49: ... water or a leak tester Once the fireplace has been finished you can now fit the frame with the small door to the operating unit Depending of enclosure After installation in a new fireplace and or applying new cement work the appliance cannot be used for at least four weeks Do not cover the top side of the appliance with built in materials DO NOT COVER BUILDING IN THE APPLIANCE ...

Страница 50: ...apted to the appliance Replacement parts including the ceramic mat are available from your dealer Fitting may only be carried out by a qualified person Ceramic log set embers vermiculite granules 1 Place the ceramic mat on the burner in such a way that the holes in the mat are in line with the burner openings Note The ceramic mat is already placed on the burner when delivered from the factory 2 Rem...

Страница 51: ...ner 0 62 in 16 mm Embers and vermiculite must not be placed next to the pilot light burner PLACING OF CERAMIC LOG SET 4 Place the ceramic logs on the burner as shown in figure 21 and figure 22 Natural gas burner à refer to figure 21 Propane burner à refer to figure 22 WARNING Make sure that the ceramic logs do not cover the burner openings ...

Страница 52: ...52 Bellfires Installation instructions PLACING OF CERAMIC LOG SET Logs Log no u Log no v Log no w Log no x Log no y Log no z Log no Log no ...

Страница 53: ...er orifices unblocked NATURAL GAS PROPANE GAS Figure 21 Log set View Bell Medium 3 CF Position natural gas burner Figure 22 Log set View Bell Medium 3 CF Position propane burner Embers must not be placed next to the pilot light burner Embers must not be placed next to the pilot light burner y z x w u v y z x w u v ...

Страница 54: ...54 Bellfires Installation instructions GAS FIRE DECORATION KITS Fire Proof Material Size Colours Stone Pebbles 1 12 30 mm Different Crushed Glass 1 12 30 mm Different Stone Pebbles Crushed Glass ...

Страница 55: ... service agency in accordance with the requirements of the manufacturer provincial or territorial authorities having jurisdiction and in accordance with the requirements of the CAN CGA B149 1 or CAN CGA B149 2 installation codes If the information in these instruction is not followed exactly a fire explosion or production of carbon monoxide may result causing property damage personal injury or loss...

Страница 56: ... bed burner and grate around the burner Make sure that the pilot light remains free IMPORTANT Do not place any pebbles glass in front of the pilot light Make sure that the pilot light can burn freely over the main burner Keep the burner orifices unblocked Keep also the back row of slots in the grate open Only this way a proper ignition of the main burner and proper combustion is ensured 8 Once the ...

Страница 57: ...Crushed Glass must not be placed in front of the pilot light burner Keep the burner orifices unblocked Keep the back row of slots in the grate open Keep the burner orifices unblocked Stone Pebbles must not be placed in front of the pilot light burner Keep the back row of slots in the grate open ...

Страница 58: ... a restriction plate with a certain width B into the ceiling of the combustion chamber To do this see the set up options as listed in figure 7 through 12 Figure 23 Positioning restriction plate The following restriction plates are supplied Dimensions in mm s Concentric flue connection appliance 5 x 7 Restriction plate Roof terminal Width B 40 mm Width B 50 mm Width B 65 mm Width B 80 mm The size of ...

Страница 59: ...es are loose by lifting a little and carefully letting them come down again Check if the packing under the hatches is sealed Check packing of overpressure hatch If necessary the packing can be replaced by lifting the hatch tilting it and removing Check functioning of overpressure hatch via the opening Left overpressure hatch is in the correct Right overpressure hatch is in the correct position pos...

Страница 60: ...n visually check the gas flame When the fire is ignited the flames should be short and blue yellow in colour These flames should gradually increase in height and become more yellow When all flames are yellow the gas fire has reached the correct temperature THE GAS FIRE IS NOW READY FOR USE ...

Страница 61: ... the pilot flame can burn at all times freely over the main burner Only in this way is proper ignition of the main burner ensured Ignoring these directions could lead to a dangerous situation Check the gas supply flue system and combustion air supply route for leaks Check the correct operation of the gas regulator block thermocouple circuit and the ignition of the main burner Check the gas inlet pre...

Страница 62: ...the pilot light Dirty electrical contacts in the thermo electrical system for example the thermocouple connection Batteries in receiver or remote control are flat SAFETY MEASURES IN THE APPLIANCE Thermo electric pilot light shut off The appliance is protected by means of a thermo electric pilot light shut off in the event of a gas escape from the main burner Over pressure safety system The applianc...

Страница 63: ...cement of the glass should be done by a licensed or qualified service person Dismantling of the glass Place paperboard on the chimney breast under the appliance This helps prevent damage View Bell Medium 3 Pull the side panel forwards on the left alongside the glass Remove the side panel on the left Pull the side panel forwards on the right alongside the glass ...

Страница 64: ...res Installation instructions DISMANTLING ASSEMBLING OF THE GLASS Remove the side panel on the right Remove the bottom panel by pulling it gently to tilt forward and to remove Prevent damage to the side glasses ...

Страница 65: ...e front under the Using a screwdriver slide the strip a glass Screws only need a couple of turns little to the left Remove the strip at the front Unscrew the long strip at the top a little and leave the strip in place Pull the glass carefully forwards at the bottom and slide it a little to one side ...

Страница 66: ...emove the glass by slanting it forward forwards a little at the bottom a little at the bottom and taking it out DISMANTLING ASSEMBLING OF THE GLASS All fastening strips on the top side remain in position The glasses at the sides can be removed in the same way as the front glass ...

Страница 67: ...s compression spring L R Assembling of the glasses The assembly of the glass takes place in reverse order Important The glass panes fit together well There must be no gaps between the glass panes or there will be a danger of flue leakage The glass panes must fit properly all round the edges of the combustion chamber Check if the fastening strips have been properly mounted all round Check if the compr...

Страница 68: ... Pilot light gas pipe Thermocouple interruptor 8 Wire connecting cable Gas pipe Front burner Gas valve Rear burner AC power adapter 110 VAC option Button RESET Receiver with battery compartment for 4 AA batteries Connection cable option for external operating i a Domotica systems Thermo electrical cable TC Thermo electrical cable SW Double burner Perforation pattern Centre Fire double burner DIAGR...

Страница 69: ...69 Bellfires Installation instructions DIMENSIONS VIEW BELL MEDIUM 3 Hidden Door ...

Страница 70: ...70 Bellfires Installation instructions OPERATING UNIT Dimensions in inches 9 7 12 4 11 3 2 14 ...

Страница 71: ... Btu hr 11 600 8 900 Supply pressure in w c 7 0 11 0 kPa 1 74 2 74 Manifold pressure maximum hot in w c 6 2 10 8 kPa 1 55 2 69 Manifold pressure maximum cold in w c 6 0 10 8 kPa 1 50 2 69 Manifold pressure minimum in w c 0 80 0 80 kPa 0 20 0 20 Main burner Injector marking back Nr 190 1xØ1 90 mm Nr 110 1xØ1 10 mm Main burner Injector marking front Nr 190 1xØ1 90 mm Nr 125 1xØ1 25 mm Pilot Injector...

Страница 72: ...8 mm for gas valve rear burner 14 333611 Olive Ø8 mm for gas valve rear burner 15 302086 Cut off nipple Ø4 mm GV 60 16 333601 Cable sw Receiver Thermocouple interrupter L 500 mm 17 333602 Cable tc Receiver Thermocouple interrupter L 500 mm 18 336505 Hand held transmitter Display screen Temperature and two programmes 19 333599 Cover battery compartment hand held transmitter with imprint Operating d...

Страница 73: ...pression elbow main burner 39 334767 Glass View Bell Medium 3 front 1007 x 467 x 4 mm 40 333227 Glass View Bell Medium 3 side 328 x 467 x 4 mm 41 301669 Tube ceramic glue 42 301593 Black fibre glass tape 15 x 3 mm adhesive 43 319664 Black fibre glass tape 30 x 2 mm adhesive 44 311006 Black fibre glass tape 20 x 2 mm adhesive 45 301617 Black fibre glass cord Ø10 mm ...

Страница 74: ...ules Appliance Log set Set Log no Art no I 332584 View Bell Medium 3 1 331357 1x 2 331358 1x 3 331359 1x 4 331360 1x 6 331362 1x 7 331363 1x 8 331364 5 331361 1x 3 pieces xxxxxx 1x Bag 125 gr 301863 3x Bag 50 gr 332583 1x Chips of Embers with Vermiculite no 4 wood set Glow effect black Anthracite filtered ...

Страница 75: ...m natural gas to propane WARNING This conversion kit shall be installed by a qualified service agency in accordance with the manufacturer s instructions and all applicable codes and requirements of the authority having jurisdiction If the information in these instruction is not followed exactly a fire explosion or production of carbon monoxide may result causing property damage personal injury or lo...

Страница 76: ...After a repair or replacement of Warranty parts the warranty period shall be deemed to have started on the date of purchase of the product by the consumer 2 6 If a certain part is eligible for the Warranty and the original part is no longer available Interfocos B V shall ensure that an alternative part of at least the same quality shall be provided 2 7 Any labour travel and shipping costs related ...

Страница 77: ...es hearth is first fired Article 7 Limitation of Liability 7 1 Interfocos B V makes no express warranties except as stated in this Warranty Interfocos sole obligation and the purchaser s exclusive remedy under this Warranty or under any other express or implied warranty in tort contract or otherwise is limited to the replacement repair or refund of parts as specified in this Warranty In no event is I...

Страница 78: ...78 Bellfires Installation instructions ...

Страница 79: ......

Страница 80: ...Serial number Production date 02 010715 337337 FOR YOUR BELLFIRES DEALER VISIT www neefireplaces ca OR www neefoyers ca ...

Отзывы: