Programming the BellProx Reader
For Security, please change the Master Code before the Reader is put into use.
Function
Keypad/Reader
Notes
Master Code:
(Required for adding and deleting Fobs and other system programming)
Enter Program
Mode
* <MASTER CODE>#
MASTER CODE
is a 6-8 Digit Code:
(Factory default is 999999)
Change Master
Code
0 <New Code> # <New Code> #
New Code
is any 6-8 Digit number
Exit Program
Mode
*
Program Mode will also timeout after 30
seconds of inactivity
Please choose the required mode before adding User Fobs or PINs: (Must be performed in Program Mode)
Working Mode:
Fob only
3 0 #
Only Fobs can be used (no PINs)
Fob and PIN
3 1 #
Fob must always be used together with a PIN
Fob or PIN
(Default )
3 2 #
Either a Fob or PIN can be assigned to each
User ID
Must be performed in Program Mode – see Master Code above
Add/Delete Fobs
Add a Fob
1 <User ID> # FOB #
User ID
a unique number from 1 to 1000
which should be assigned to each Fob
FOB
Hold the Fob to the reader
Add a PIN to the Fob
(Mode 31)
Add a Fob first as above then
Exit Program Mode.
PIN can be added to Fob in User Mode
(See User Instructions below)
Add a PIN only
(Mode 32)
1 <User ID> # PIN # *
User ID
a unique number from 1 to 1000
which should be assigned to each Fob
PIN
Any 4-digit number (except 1234)
Delete a Fob
using the Fob
2 FOB #
In Mode 31 the associated PIN is deleted too.
Delete a Fob/PIN
using the User ID
2 <User ID> # *
Delete all Fobs/PINs
2 0 0 0 0 #
Use with caution!
Misc
Factory Reset
Power Down the Reader:
Hold down the # key:
Power Up:
Release the # key after two beeps
Does not delete Fobs or PINs
Master Code is reset to 999999