bell
issimo
2-72 Way Video Entry System
PD-098 Issue 4B
Installation and Operating Manual
Page 38 of 44
Diagram K – bell
issimo
Combined System Connections
Connecting a Bellcode Coded Access Controller
Connect the lock release as per this manual. Leave the Bellcode controller set
to fail secure, the BSD controller sets the lock type.
See "Bellcode Manual inc CK200 CS109 (PD-078)" for the other installation and
setting instructions.
Note 1.
A normally open exit button can still be wired to the Bellcode unit in addition to
the bellissimo wiring.
Note 2.
A “12V -” connection will be required if the 2 units are not sharing a power
supply.
Connecting a Bell PAX1 Proximity Reader
Connect the lock release as per this manual. Leave the Proximity Reader set to
fail secure, the BSD controller sets the lock type.
Note 1.
A normally open exit button can still be wired to the BSD controller in addition to
the proximity wiring.
Opening a Gate or Locks on Third Party Systems
Leave the BSD controller set to Fail secure.
Use COM and NO or COM and NC as required for the gate controller or third
party access system.