background image

unit  on  a  desk,  table,  etc.  within  25  feet  of  the 

jack  and  within  10  feet  of  a  grounded  power  outlet 

supplying  120  volts  ac,  60  Hz. 

Ensure  that  the  power  cord 

is 

connected 

to  an  ac  outlet  not  under  control  of 
a  switch. 

3.02 

Arrange  control  unit  so  front  is  located  at 

least  six  inches  from  table  edge  and  with 

its  loudspeaker  facing  the  audience.  For  optimum 
performance,  there  should  be  no  obstructions  at 
the  front,  rear,  or  within  one  foot  of  the  sides  of 

the  unit. 

3.03 

Install  telephone  line  cord,  ac  power  cord, 
and,  as  required,  microphones  or  auxiliary 

TOUCH-TONE  dial telephone  set  to the appropriate 

jacks  located  on  rear  of  control  unit  (Fig.  2). 

.111111001�1111�0011111111 

Fig. 

2-738 

Control  Unit,  Rear  View 

3.04 

Provision  is  made  for  reproducing  both 

transmitted  and  received  signals  over  a 

customer-owned  public  address  system.  A  public 
address  adjustment  (PA  ADJ)  (Fig.  2)  control  is 

located  on  the  back  of  the  set  for  adjusting  the 
level of  the  transmitted  signal  at  the  PA  terminals. 
Connections  to  the  public  address  system  are  made 

to  the  screw  terminals  on  the  bottom  of  the  unit 
(Fig.  3). 

Connections  should  be  made  using  a 

shielded pair, grounded at the customers'  equipment 
only. 

If  desired,  the  conference  set  loudspeaker 

ISS 

2, 

SECTION 

5 12-630- 11 1 

can  be  deactivated  by  opening  the  shorting  link 
between  adjacent  screw  terminals  on  the  base  of 

the  control  unit  (Fig.  3). 

Connection  to  and 

adjustment  of  the  PA  system  is  the  customer's 

responsibility.  Typical  signal  levels  are-45dbv  at 
600-ohm  impedance  (balanced). 

A- REAR  HOUSING  ASSY  CAPTIVE  SCREW  ACCESS  HOLES 

B-

MICROPHONE  AND  FRONT  HOUSING  ASSY  SCREWS  AND 

CAPTIVE  SCREW  ACCESS  HOLE 

Fig. 

3-738 

Control  Unit,  Bottom  View 

3.05 

When  the  conference  set  is  not  in  use  or  is 
being  moved  to  another  location,  store  the 

components  and  control  unit  in  the  carrying  case. 

3.06 

When  installed  behind  a  1A1,  1A2,  or  6A 

KTS,  the  A  and  Al  leads  from  the  KTS 

should  be  connected  to  the  T1  and  R1  leads, 
respectively,  of  the  control  unit  to  obtain  A  lead 
control. 

There  are  several  ways  to  connect  the 

50A1  to  a  key  system  termination. 

(1)  A  special  connector  (F-Specification  59888) 

can  be  ordered  separately  with  a  modular 

plug  at  the  50A1  end  and  a  153-type  adapter 
wired  to  pick  up  tip,  ring,  A  and  Al  leads  at 

the  key  system  end. 

Page 

BSP 

S12·630·111-102_1979-QS-03.jpg  Scanned by  Frank Harrell, {Cowboy  Frank) Castle  Rock, Colorado  Feb 16,2012  23:01:01 

Содержание 50A1

Страница 1: ...RFI will be stamped on the underside of the base upon completion of modification 2 IDENTIFICATION 2 01 The 50A1 conference set Fig 1 consists of a 73B control unit a modified 220A 58 hand telephone set plus the other accessories listed in paragraph 2 03 under the Ordering Guide A Ordering Guide 2 02 The 50A1 conference set can be ordered as a complete unit as follows Set Conference 50Al 2 03 The f...

Страница 2: ... NET c RR Ll L2 CONNECT TO POLARITY TERM GUARD BOARD s s T 1 Handset communication using a TRIMLINE hand telephone set Transferring between hands free and handset during conversation One way communication using the loudspeaker only A lead control for use with key telephone systems Means to provide audible TOUCH TONE signals for computer data input Means to connect both transmitted and received sig...

Страница 3: ...Connections should be made using a shielded pair grounded at the customers equipment only If desired the conference set loudspeaker ISS 2 SECTION 512 630 11 1 can be deactivated by opening the shorting link between adjacent screw terminals on the base of the control unit Fig 3 Connection to and adjustment of the PA system is the customer s responsibility Typical signal levels are 45dbv at 600 ohm ...

Страница 4: ...rol unit is deactivated whenever the handset is lifted 4 05 Incoming calls are heard through the set loudspeaker The output level is adjusted Page 4 by means of the VOLUME control Advance the VOLUME control only far enough for adequate listening level However when this control is set at 0 a lecturer speaking into the conference set will be heard more clearly at the remote location since the set wi...

Страница 5: ...cord and the D4BU line cord before attempting any maintenance to the interior of the control unit 5 01 Set repair at customers premises should be limited to replacement of those parts listed in the Ordering Guide Repair of other components affects set performance and requires detailed testing 5 02 To remove the front and rear housing assemblies fromthe73B control unit disconnect the hand telephone...

Страница 6: ... JOY P IJER SUPPLY CPI lOY ISV KI PI F LG r 1 orr PI TBI LINE SWITCH P2 6 3 RI 270 PRE AMPL P 0 CP2 P6 MIKES OFF r 6 fl 5 PS TRANSMISSION AND CONTROL CIRCUITS CP2 6 PA OUTPUT CUSTOMER EQUIPMENT K I SET MIKE ON P2 GOLD Ml KE 5 GREEN IKE AUX DIAL MIKES orr I Fig 4 SOA 1 Conference Set Block Diagram Sheet 1 of 2 Page 6 SSP 512 630 111 i02_1979 05 06 jpg Scanned by Frank Harrell Cowboy Frank Castle Ro...

Страница 7: ...DIAL I T W R BL 5 R I I I I I I I I I I R13 L r 2 LINE I 3 2W SWITCH I II 110 411 HAND TELEPHON SET CORD JACK H40B COHO NC t L o Jiz BK T NC tKI 2W II R I G __ ___ 11 LINE SIIITCH R LG I II NOTES j k I REPLACE DIOP MOUNTING CORD fURNISHED WITH 25005 TELEPHONE SET liTH A S3A SWITCHBOARD CORD EQUIPPED liTH A 309 PLUG Oil EQUIVALENT ORDERED SEPARATELY SPECIfY LENGTH AND COLOR OF CORD SEE TABLE A FOR ...

Страница 8: ...ophones Using Lavaliere and Holder Page 8 8 Pages 2 I 4 WIRE SELECTOR SWITCH IIIII Fig 6 738 Control Unit Rear Housing Removed SSP 512 630 111 i01_1979 QS 08 jpg Scanned by Frank Harrell Cowboy Frank Castle Rock Colorado Feb 16 2012 23 01 06 ...

Отзывы: