ISS  1,  SECTION  502-502-101 

TABLE  E 

LINE  AND  RINGER  CONNECTIONS  FOR  1554B  TELEPHONE  SETS 

TIP  PARTY 

INDIVID 

WIRE  OR  LEAD 

OR 

RING 

IDENTIFYING  GROUND 

PARTY 

NO  IDENT. 

BRIDGED 

GROUND 

10000 

2650() 

Line  Wire 

Ringer 

BK 

Leads 

(Note) 

S-R 

• 

• 

BL 

• 

Line 

Ft 

Ft 

Switch 

BR 

Ft 

Ft 

Ft 

*Insulated  and  stored. 

tMay  be  terminal 

in  older  sets  equipped  with  4010B  networks. 

Notes: 

1. 

(S) 

ringer  lead  may  appear  on  terminal  L2  in  sets  manufactured  from 

1964 

to  8 

1964. 

(BL)  ringer  lead  furnished  on 

PIA 

ringer  only. 

2. 

To  silence  ringer  permanently: 

(a)  For  all  classes  except  tip  party  with  identifying  ground,  remove  (BK)  ringer  lead, 

insulate  and  store  or  place  on  unused  terminal. 

(b)  For  tip  party  with  1000  or  2650  ohm  identifying  ground,  remove  (R)  ringer  lead 

insulate  and  store  or  place  on  unused  terminal. 

TABLE  F 

MODIFICA liONS  FOR  1 A 1  OR  1 A2  KTS 

FOR  1554B  TELEPHONE  SETS 

WIRE  OR  LEAD 

DISCONNECT 

CONNECT 

FROM 

TO 

Line 

Ll 

Switch 

BR 

BLt 

L2 

Ot 

L2 

Add 

Ml 

cord  or  equivalent  from 

to 

• 

Insulated  and  stored. 

If  leads  are  not  present,  strap  C  to 

2  with  Ml W 

cord. 

Note: 

For  common  audible 

with  lAl  or  1A2 

KTS. 

Connect 

81 

and  (BK)  ringer  lead  to 

L2 

and 

Rl  to 

K. 

Ml W 

cord  not 

required. 

BSP  5

0

2

-

5

0

2

-

101

-

i

01

_

1970

·

0

2-

07.

j

p

Scanned by  Frank Harrell, !Cowboy  Frank) Castle Rock, Colorado  Jan 30, 2012  22:41:13 

Page 

Pages 

Содержание 1500D

Страница 1: ...IIIIIIII 11mIii IiiiiI i sss 2 _ o c 15549 TELEPHONE SET maintenance and connection information for general purpose telephone sets previously contained in Sections 502 510 111 502 510 440 and 502 510 431 which are hereby canceled 2 01 General purpose TOUCH TONE dial desk and wall type telephone sets merican Telephone and Telegraph Company 1970 Printed in L l BSP 502 502 101 101_1970 02 0l jpg Scan...

Страница 2: ...uard assembly see Table C Page 2 3 INSTALLATION 3 01 Exercise care not to damage line switch on early models of 1554B sets without line switch guard when drilling or driving screw in mounting hole 4 MAINTENANCE 4 01 Replaceable Apparatus Refer to Table B for component ordering guide Component parts should be maintained in accordance with section covering the particular item 4 02 To remove housing ...

Страница 3: ...NG PARTY REFER TO TABLE D FOR CLASSES OF SERVICE NOT SHOWN INDICATES CURRENT COLOR CODE INDICATES MD COLOR CODE WITH 2 5A3 DIAL Fig 2 15000 Telephone Set Connections BSP 502 502 101 i01_1970 02 03 jpg Scanned by Frank Harrell Cowboy Frank Castle Rock Colorado Jan 30 2012 22 39 11 ISS I SECTION 502 502 101 Page 3 ...

Страница 4: ... G DIAL LEADS MAY APPEAR ON F IN SETS EQUIPPED WITH 40100 NETWORK 4 LINE SWITCH OFF HOOK SEQUENCE I b e CLOSES 4 a b OPENS 121 d e CLOSES 51 f g OPENS 3 j k CLOSES 5 SET FACTORY WIRED FOR BRIDGED SERVICE REFER TO TABLE E FOR CLASSES OF SERVICE NOT SHOWN 6 REFER TO TABLE F FOR MODIFICATIONS FOR IAI OR IA2 KTS INSULATED AND STORED 0 BKI WITH 25W3 DIAL WITH 25A3 liD DIAL Fig 3 1 5548 MD Telephone Set...

Страница 5: ...D053 Telephone set must be equipped with a 25W3 or 25Y3 dial as appropriate if intended for use with amplifying handset or 3 type speakerphone system ISS 1 SECTION 502 502 101 TABLE C POLARITY GUARD CONNECTIONS FOR 1500D AND 1554B TELEPHONE SETS DISCONNECT CONNECT FROM TO LEAD NETWORK NETWORK POLARITY GUARD Dial BK RR T Line Switch BR c s Polarity G RR Guard w c Depending on class of service set T...

Страница 6: ... L2 L2 A A Line Switch W S W F F F c c BR S BR c c c F F Note To permanently silence ringer for all classes of service except identifying ground connect Y mtg cord lead with R mtg cord lead at conn block a For 1000 ohm ground insulate and store or place S R ringer lead on unused terminal b For 2650 ohm ground insulate and store or place BK ringer lead on unused termi nal Current color code MD colo...

Страница 7: ...manently a For all classes except tip party with identifying ground remove BK ringer lead insulate and store or place on unused terminal b For tip party with 1000 or 2650 ohm identifying ground remove R ringer lead insulate and store or place on unused terminal TABLE F MODIFICAliONS FOR 1 A1 OR 1A2 KTS FOR 1554B TELEPHONE SETS WIRE OR LEAD DISCONNECT CONNECT FROM TO s A Line y 2 Ll Switch BR c 3 B...

Отзывы: