BHT-407-MM-1
5-00-00
ECCN EAR99
APPENDIX A
M407 INSPECTION — CHECKLIST
GENERAL
1.
Make sure that all of the applicable and the required Scheduled Inspections, Special Inspections, Technical
Bulletins, Alert Service Bulletins, and Airworthiness Directives (A.D.) are completed:
2.
Make sure that the required inspections and the tests for installed optional equipment are completed:
3.
Make sure that the required Special Inspections are completed. Refer to the applicable chapter of this
manual or to the Maintenance Manual Supplement:
4.
Replace all of the life limited components that have completed their specified operating life (Chapter 4):
5.
Remove and overhaul all of the components that have completed their specified operating life. Refer to the
Component Overhaul Schedule (Table 5-4) in this chapter:
6.
If an instrument shows an Exceedance, conduct the required inspection and make sure that there is a log
book entry for this instrument:
16 FEB 2012 Rev. 34
Page 95/96