Symptom

LED Sequence Code

LED Sequence  

Code Error

Possible Causes

Corrective Action*

Intermittent Operation

1x Long, 4x Short

1x Long, 3x Short, 1x Long

1x Long, 2x Short, 1x Long, 1x Short

1X Long, 2x Short, 2x Long

1x Long, 1x Short, 1x Long, 2x Short

1x Long, 1x Short, 1x Long, 1x Short, 1x Long

Run Error #1

Run Error #2

Run Error #3

Run Error #4

Run Error #5

Run Error #6

1.  Improperly Wired

2.  Foreign object in impeller and housing

3. Overheated pump electronics

1.  Check Motor wiring diagram

2.  Disassemble pump, remove object, and clean 

motor separating wall and impeller

3.  Disconnect the power to the pump and let 

the pump cooled down to ambient room 

temperature. Check the fluid’s temperature for 

proper setting.

Pump will not prime

1x Long, 1x Short, 2x Long, 1x Short

Dry-Run Error

1 . Leak, Obstruction, or kink in suction line 

2 . Suction line closed 

3.  Pump is worn

1. Repair as necessary.

2. Open, then reset the pump by unplugging power 

to the pump

3. Replace parts.

Little or no discharge

Solid Light

No Error

1.  Housing not filled with water 

2.  Suction piping too small 

3.  Total head too high 

4.  Impeller plugged

1.  Properly prime housing

2.  Increase to pump inlet size or one size larger

3.  Reduce discharge head

4.  Disassemble pump and clean motor separating 

wall and impeller

Noisy pump operation

Solid Light

No Error

1.  Air trapped in housing 

2.  Rotor bearing worn 

3.  Debris in housing

1. Check pump prime, also turn pump on and off 

several times to bump air pocket out of pump

2. Replace rotor assembly

3. Dissemble pump and remove debris

No Operation

No Light

Not Powered

1.  Blown Fuse or open circuit breaker 

2.  Loose or broken wiring

1. Replace fuse or circuit breaker after reason for 

overload has been corrected

2.  Tighten connections, repair wiring

Trouble Shooting Chart

LED Indicator:  Solid green LED indicates pump is powered and functioning properly. If flashing green LED please follow the  

Corrective Actions for the errors below. 

1

6

5

4

3

2

7

vario Pump Curves

auto Pump Curve

vario Pump Curve

Setting 1

Setting 2

Setting 3

Setting 4

Setting 5

Setting 6

Setting 7 

1
2

3

4
5

6
7

* If the LED sequence code continues after all corrective actions have been verified and applied, please contact your local B&G 

representative for assistance and report the run error sequence when the pump is returned for a warranty replacement.