Power LED

 

Error LED

 

Test in progress LED

 

MP address display

 

Registered actuator LED

 

Individual Neuron ID

 

Status LED function according to        

 

Echelon Guidelines

 

Service button for commissioning  

 

with L

ON

W

ORKS

®

 

Unit power supply AC or DC 24 V

 

SET button for MP addressing

 

Up button for MP addresses

 

Start test button

 

MP connector: For connecting             

 

MFT(2)/MP actuators

 

MFT-H connector: For connecting the  

 

MFT parameterising tool

 

L

ON

W

ORKS

® 

connector

 

Node label

The operating controls numbered 

are described below in greater detail. 

Automatic scanning 

of the MP network

As soon as the UK24LON unit is power-

ed up it starts scanning the MP network 

automatically. All eight MP addresses are 

interrogated cyclically to see whether the-

re is an actuator available to respond. The 

results are compared against a reference 

table stored in the UK24LON unit. If an ac-

tuator responds from an MP address that 

is not assigned in the reference table it is 

automatically inserted into the table.

If an actuator already assigned in the refer-

ence table fails to respond an error alarm 

is  initiated  but  the  reference  table  is  not 

altered in any way. The actuators can be 

pre-addressed so that they are recognis-

ed automatically when they are connect-

ed to the MP network.

Manual addressing 

of actuators 

  All required actuators must be connect-

ed first.

  Use  the 

Up

  button        to  select  the 

address  to  be  issued.  The  actual  add- 

ress will be shown on the display      .

  Use  the 

Set

  button      to  start  the  

addressing  process  (hold  for  at  least  

2  seconds).  The 

Reg’d

  LED            starts 

flashing slowly (at 

1

2

 second intervals) 

to  indicate  that  the  process  is  in  pro-

gress.

  Within the next 10 minutes, the MFT(2)/

MP actuator being addressed must be 

reset  (in  the  case  of  standard  damper 

actuators  by  pressing  the  addressing 

button; in the case of spring return ac-

tuators by moving the L/R switch back 

and forth and in the case of globe valve 

actuators  by  pressing  the  S2  button). 

The UK24LON unit will then be able to 

recognise  and  address  the  actuator. 

This status is indicated by fast flashing 

of the 

Reg’d

 LED     .

  As  soon  as  addressing  of  the  actua-

tor has been completed the 

Reg’d

 LED 

    – gives a steady light. This also indi- 

cates  that  the  MP  address  has  been 

successfully stored in the reference ta-

ble of the UK24LON unit.

Notes on addressing

  If  none  of  the  actuators  has  been  re-

set within 10 minutes of the addressing 

process being initiated, the process will 

be discontinued. The reference table re-

mains  unchanged  and  the 

Reg’d

  LED 

-      stops flashing.

  If an address is issued that has already 

been  assigned  to  another  actuator  the 

latter is automatically de-addressed first 

before the new actuator is addressed.

  If a mistake is made in initiating address-

ing,  the  process  can  be  stopped  by  

briefly pressing the 

Set

 button      .

  Normal data traffic on the MP network 

is interrupted while addressing is in pro-

gress.

Manual de-addressing 

of MFT(2)/MP actuators

  All actuators that are to be de-addressed 

must be connected first.

  Press  the 

Up

  button          to  select  the 

address  to  be  deleted.  The  current 

address is shown on the display     .                

  Start  de-addressing  by  pressing  the 

Set button      (min. 2 s). The Reg’d LED 

     flashes slowly as a check (every 

1

2

 

second).

  Press the 

Set

 button     a second time 

until the 

Reg’d

 LED      flashes rapidly.

  The 

Reg’d

  LED        goes  out  after  the 

actuator  has  been  de-addressed,  i.e. 

removed  from  the  reference  table  and 

set to the address "PP".

Operation, characteristics of the UK24LON unit

Power

Error

MFT - H

UK24-LON

Service

Made in Switzerland

Status

Node

IC-DZ.03

Test

Test in

Progress

Address

Select

Up

Set

Reg'd

MP-Com.

24V

0V

Y

U/MP

Power

n.c.

LonTalk

a

b

24V

0V

NID: XXXXXXXXXXXX

1

16

3

7

8

15 14

13

12 11 10

9

2

5

4

6

UK24LON

Legend for operating controls

10

11

12

13

14

15

16

11

4

10

5

5

5

11

4

10

10

5

5

5

5

1

2

3

4

5

6

7

2

3

4

5

7

10 11 12

8

9

ENG

 · 

02.0

7· 

PDF · 

Subject to technical changes

b0291102

10

Operation, Characteristics

Содержание UK24LON

Страница 1: ...2 4 5 6 UK 4 Product Information UK24LON Gateway MP LONWORKS UK24LON LONWORKS LONMARK UK24LON i0385102...

Страница 2: ...sions 5 Complete MFT 2 MP assortment 5 Connecting MFT 2 MP actuators 6 Connecting sensors 6 MP Bus conductor lengths 7 Functional Profile 8 9 SNVT functions of the function objects 10 Operation Charac...

Страница 3: ...nnected to them to the LONWORKS system ENG 01 07 PDF Subject to technical changes i0387102 MP Bus p LONWORKS p t t t UK24LON Typical applications of the UK24LON VAV air volume controllers for supply a...

Страница 4: ...data UK24LON unit Power supply AC 24 V 50 60 Hz DC 24 V Functional range AC 19 2 28 8 V DC 21 6 28 8 V For wire sizing 3 VA without MFT 2 MP actuators connected Power consumption 1 5 W Connections LON...

Страница 5: ...bject to technical changes d0096102 Damper actuators with or without safety function Actuators for characterised control ball valves with or without spring return function MP VAV devices Actuators for...

Страница 6: ...eans of digitising the analogue signal from the sensor through the actuator so that it can be passed on to LONWORKS via the UK24LON unit Connecting passive sensors Pt1000 Ni1000 NTC Connecting active...

Страница 7: ...ctuators can be connected to each network No special cable or terminating resistors are needed Conductor lengths are limited see below for methods of calculation by the total power rating of the MFT 2...

Страница 8: ...ppropriate box and can be used for control and indicating pur poses MP VAV only Open Loop Sensor Object 1 One sensor can be connected to each MFT 2 MP actuator It can be either a passive resistance ty...

Страница 9: ...SCPTmaxSendTime 49 SCPTsndDelta 27 UCPTadFunction 1 UCPTadTranformation 2 SCPTtrnsTblX 28 SCPTtrnsTblY 29 SCPTinvrtOut 16 Damper Actuator Object 8110 nviRelStpt SNVT_lev_percent nviActuatState SNVT_s...

Страница 10: ...in LONMARK functional profile 8110 see www lonmark org nvoActualValue Actual value for actuator position 0 100 stroke nvoAbsAngle SNVT displays a constant value of 655 34 for a valve actuator this is...

Страница 11: ...axSendTime 49 SCPTmaxRcvTime 48 SCPTminDeltaAngl 43 SCPTminDeltaFlow 47 SCPTactuatorType 41 SCPToemType 61 SCPTlocation 17 SCPTnomAngle 58 SCPTnomAirFlow 57 SCPTminSetpoint 53 SCPTmaxSetpoint 50 SCPTd...

Страница 12: ...switch back and forth and in the case of globe valve actuators by pressing the S2 button The UK24LON unit will then be able to recognise and address the actuator This status is indicated by fast flas...

Страница 13: ...Note By holding the button depressed for more than 2 seconds all addressed and responding actuators can be tested simultaneously No mechanical testing of actuators can be initiated at addresses that...

Страница 14: ...14 Notes...

Страница 15: ...15 Notes...

Страница 16: ...tralia Austria Bahrain Belgium Bosnia Herzegovina Brazil Bulgaria Canada Chile Croatia Cyprus Czech Republic Denmark Egypt Estonia Finland France Great Britain Germany Greece Hong Kong Hungary Iceland...

Отзывы: