LMC230, LMC230-S Damper actuators 2 Nm 

5

Dimensions

0

1

94.1

89

116.2

22.1

66.2

5.2

59

33.5

6...16

d0001805

1

2

3

LMC230-S

S1 S2 S3

0...100%

Wiring diagram

N   L1  AC 230 V

LMC230

Parallel connection of several actuators
with 1 - wire control possible.
Power consumption must be observed.

To isolate from the main power supply, the system
must incorporate a device which disconnects the
phase conductors (with at least a 3 mm contact gap).

Subject to technical changes / 01.00

Application

The type LMC230(-S) is intended for the
operation of air control dampers in venti-
lation and air-conditioning systems.

Mode of operation

Open/Close control by single-wire system.

Product features

Simple direct mounting 

on the damper

spindle by universal spindle clamp. An
antirotation device is supplied to prevent
unwanted rotation of the whole unit.

Manual operation 

by self-resetting push-

button when necessary (the gearing is
disengaged while the pushbutton is held
depressed).

Adjustable angle of rotation 

with me-

chanical stops. 

High functional reliability

The actuator is overload-proof, needs no
limit switches and halts automatically at
the end stops.

Flexible signalling 

0…100%, with adjust-

able auxiliary switch (LMC230-S only).

Mounting instructions

, page 6

Adjusting auxiliary switch LMC230-S,

page 7.

Important

Read the notes about the use and torque
requirements of the damper actuators on
page 2.

Dampers up to approx. 0.4 m

2

Open/Close actuator (AC 230 V)

Control by single-pole contact
(single-wire control) 

Running time < 35 s

Direction of rotation

selected with L/R switch

Torque

min. 2 Nm 

(at rated voltage)

Angle of rotation

max. 95°

(adjustable by mechanical stops)

Running time

25… 35 s  

(0… 2 Nm)

Power consumption

1.5 W

For wiring sizing

15 VA

Nominal voltage

AC 230 V

50/60 Hz

Nominal voltage range

AC 198...264 V

Manual operation

pushbutton, self-resetting

Auxiliary switch 

(LMC230-S)

1

×

SPDT 5(2.5) A, AC 250 V 

– Switching point

adjustable 0…100% 

Connecting cable

– motor

1 m long, 3

×

0.75 mm

2

– auxiliary switch 

(LMC230-S)

1 m long, 3

×

0.75 mm

2

Technical data

LMC230, LMC230-S

Position indication

mechanical with pointer

Protection class

II 

(all insulated)

Maintenance

maintenance-free

Weight

610 g

Degree of protection

IP 54 

(bottom cable entry)

EMC

CE according to 89/336/EEC, 92/31/EEC, 93/68/EEC

Low Voltage Directive

CE according to 73/23/EEC

Ambient temperature range

– 30… + 50 °C

Non-operating temperature

– 40… + 80 °C

Humidity test

to EN 60335-1

Sound power level

max. 45 dB(A)

aw090001

ap020901

B

C

Содержание LMC230

Страница 1: ...heating ventilation air conditioning new supplement to replaces several data sheets OEM at004707 at001707 at021901 KARTY KATALOGOWE w j polskim przesyłamy na życzenie fax em Biuro Handlowe MERPRO Sp z o o ul Ścinawska 43 60 178 POZNAŃ tel 0048 61 8685629 fax 0048 61 8685940 E mail bh merpro pl www merpro pl ...

Страница 2: ...d for the operation of air dampers in HVAC systems Torque requirements When calculating the torque required to operate dampers it is essential to take into account all the data supplied by the damper manufacturer concerning cross sectional area design mount ing and air flow conditions B C ...

Страница 3: ...trol and monitoring functions 10 Contents Nominal voltage AC 24 V DC 24 V AC 230 V Running time 25 35 s Control Open Close Single wire 2 wire Modulating DC 0 10 V Direction of rotation reversible right left Manual operation by pushbutton Auxiliary switch potential free Mechanical angle of rotation limiting Electronic angle of rotation limiting Continuous position feedback Damper rotation with univ...

Страница 4: ... time 35 s Dimensions Subject to technical changes 01 00 Direction of rotation selected with L R switch Torque min 2 Nm at rated voltage Angle of rotation max 95 adjustable by mechanical stops Running time 25 35 s 0 2 Nm Power consumption 2 W For wiring sizing 3 VA Nominal voltage AC 24 V 50 60 Hz DC 24 V Nominal voltage range AC DC 19 2 28 8 V Manual operation pushbutton self resetting Auxiliary ...

Страница 5: ...stops Flexible signalling 0 100 with adjust able auxiliary switch LMC230 S only Mounting instructions page 6 Adjusting auxiliary switch LMC230 S page 7 Important Read the notes about the use and torque requirements of the damper actuators on page 2 Dampers up to approx 0 4 m2 Open Close actuator AC 230 V Control by single pole contact single wire control Running time 35 s Direction of rotation sel...

Страница 6: ...Mounting instructions LMC24 S LMC230 S 6 3 2 1 m i n 3 5 m m 6 16 3 5 6Nm 1mm 2 1 1 3 2 5 4 m0001707 Subject to technical changes 01 00 B C ...

Страница 7: ...switch is needed to operate e g at 60 angle of rotation Turn the scale knob of the auxiliary switch anticlockwise ccw until the tip of the arrow is just past the scale zero Connection S1 to S3 made and switching position set for 60 angle of rotation Option 2 Actuator at switching position Procedure Depress the manual operation pushbutton and move the actuator to the position where the auxiliary sw...

Страница 8: ...ee of protection IP 54 bottom cable entry Ambient temperature range 30 50 C Non operating temperature 40 80 C Humidity test to EN 60335 1 EMC CE according to 89 336 EEC 92 31 EEC 93 68 EEC Maintenance maintenance free Weight 620 g Dampers up to approx 0 4 m2 Modulating damper actuator AC DC 24 V Control DC 0 10 V and posi tion feedback DC 2 10 V Running time 35 s Application The type LMC24 SR is i...

Страница 9: ... 2 1 1 2 3 4 5 Mounting instructions for LMC24 SR 9 Mounting on anticlockwise closing damper Mounting on clockwise closing damper m i n 3 5 m m 6 16 3 2 1 3 5 6Nm 2 1 100 20 1 2 3 4 5 m0006707 m0007707 Subject to technical changes 01 00 B C ...

Страница 10: ...umption data Y DC 0 10 V a b 5 U a b control mode T Reversing switch R Reversing switch L T AC 24 V DC 24 V Connect via safety isolating transformer Y 1 2 3 Position indication LMC24 SR 5 U T AC 24 V T 1 2 3 ZAD24 4 Direction of rotation Connect via safety isolating transformer Y 1 2 3 Master slave control depending on position LMC24 SR 5 1 2 3 5 to next actuator Master actuator Note 5 synchronism...

Отзывы: