Service Tools connection

 

The actuator can be parameterised by 

ZTH AP

 via the service socket.

For an extended parameterisation the PC tool can be connected.

 

Connection 

ZTH AP

 / PC-Tool

1

3

2

5

AC 24 V
DC 24 V

–     + 

T

~

U

Y

Y
U

BELIMO
PC-Tool

USB

MP

US

B

 

i

esc

OK

ZTH 

AP

Dimensions / Weight

Dimensional drawings

L

H

min. X

min. Y

D

K

d

If Y <180 mm, the extension of the hand crank must be demounted as necessary.

Type

DN

[ ]

L

[ mm]

H

[ mm]

D

[ mm]

d

[ mm]

K

[ mm]

X

[ mm]

Y

[ mm]

Weight

MP

65

379

205

185

4 x 19

145

220

150

26 kg

MP

80

430

205

200

8 x 19

160

220

160

35 kg

MP

100

474

221

229

8 x 19

180

240

175

52 kg

MP

125

579

249

252

8 x 19

210

260

190

70 kg

MP

150

651

249

282

8 x 23

240

260

200

90 kg

Further documentation

• Overview MP Cooperation Partners

• Tool connections

• Introduction to MP-Bus Technology

• General notes for project planning

EP..F+MP

Electr. 2-way PI-CCV EPIV, Flange, PN 16

Service

www.belimo.com

EP..F+MP • en-ap • 2019-06-03 • subject to changes

10

Содержание EP065F+MP

Страница 1: ...13 VA Connection supply control Cable 1 m 4 x 0 75 mm Parallel operation Yes note the performance data Functional data Torque Motor 20 Nm DN 65 80 40 Nm DN 100 150 Operating range Y DC 2 10 V Input I...

Страница 2: ...ording to the data sheet Only authorised specialists may carry out installation All applicable legal or institutional installation regulations must be complied during installation The connection betwe...

Страница 3: ...water volumetric flow Curve 1 With the classical type of temperature control an attempt is made to maintain the control signal Y proportional to the power Q Curve 2 This is achieved by means of an equ...

Страница 4: ...l parameters in connection with the precise flow rate sensor ensure a stable quality of control They are however not suitable for rapid control processes i e for domestic water control U5 displays the...

Страница 5: ...contact The MP actuator serves as an analogue digital converter for the transmission of the sensor signal via MP Bus to the higher level system Configurable actuators The factory settings cover the m...

Страница 6: ...actuators VAV controller and HVAC performance devices ZTH AP Belimo PC Tool Software for adjustments and diagnostics for MF MP MOD LON KNX actuators incl fire protection CD with Software and instructi...

Страница 7: ...2 V Resolution 30 mV 1 2 3 5 MP T U Y A p A more actuators and sensors max 8 Switching current 16 mA 24 V Start point of the operating range must be parameterised on the MP actuator as 0 5 V Functions...

Страница 8: ...under normal circumstances even filling water with a lower conductivity will experience an elevation of its conductivity to above the minimum required value during filling and that the system can thu...

Страница 9: ...ial pressure pressure drop The minimum required differential pressure pressure drop through the valve for achieving the desired volumetric flow max can be calculated with the aid of the theoretical kv...

Страница 10: ...ed as necessary Type DN L mm H mm D mm d mm K mm X mm Y mm Weight EP065F MP 65 379 205 185 4 x 19 145 220 150 26 kg EP080F MP 80 430 205 200 8 x 19 160 220 160 35 kg EP100F MP 100 474 221 229 8 x 19 1...

Отзывы: