PROGRAMMING TOOLS 

Near Field Communication (NFC) App

Allows fast programming, commissioning, and troubleshooting even when the
actuator is not powered. Available through Google Play

Where Available on NFC Labeled Actuators Only

MFT-P

Belimo MFT confi guration software (V3.X), includes PC-Tool software
(interface cables [ZTH US] not included).
Physical copy of software. Free download also available at
www.belimo.us/americas/mft.html

Available for all MFT Actuators

ZTH US

Handheld interface module that
allows fi eld programming. Includes ZK1-GEN, ZK2-GEN,
and ZK6-GEN cables

Available for all MFT Actuators

COVERS

ZS-T

Terminal cover for NEMA 2, -T models

Available for all -T Model Actuators

(except TR)

Valve Accessories

Tech.Doc - 04/17 - 

S

ubject to change. 

©

 Belimo Air

controls 

(U

S

A

), Inc

.

Содержание B2100VB-024

Страница 1: ...carbon steel bodies ideal for aggressive applications Fluid temperature up to 380 F is ideal for chilled hot water or steam service Fitted with rotary actuators for easy field assembly and installatio...

Страница 2: ...ion code X XXXXX Create custom MFT configuration in the field with MFT actuator PC Tool software Non Spring Models NO Normally Open NC Normally Closed Spring Return Models NO FO Normally Open Fail Ope...

Страница 3: ...le 1 to 2 ANSI flanged 3 to 6 Materials Body carbon steel Characterizing ball hardened chrome plated stainless steel Stem stainless steel Seats Teflon O rings ALFAS Stem packing spring loaded Teflon V...

Страница 4: ...ion Actuator will fail closed A to AB upon power loss NFX24 MFT X1 AFX24 MFT X1 EFX24 MFT NC FO Normally closed A to AB valve will open as voltage increases Actuator switch on CW Spring Action Will fa...

Страница 5: ...applications For steam applications the valve can be mounted vertically but if mounted horizontally the valve must be 90 off center of the pipe Do not install with actuator below pipe A AB Water Appli...

Страница 6: ...convection and radiation is above 122 F for prolonged time periods at the actuator Following standard procedure a strainer should be installed before the coil and valve or in another appropriate plac...

Страница 7: ...Cv 5 Fp Cv 6 Fp Cv 8 Fp Cv 10 Fp Cv 1 24 2 Way NPT B2100VB 024 24 0 22 6 21 1 19 3 1 55 2 Way NPT B2150VB 055 55 0 50 4 46 3 43 9 2 77 2 Way NPT B2200VB 077 77 0 74 1 70 5 66 2 3 207 2 Way Flanged B6...

Страница 8: ...are connected together a short circuit is created across one of the diodes in the full wave power supply damaging the controller Only use a single power transformer to power the controller and actuato...

Страница 9: ...nch is required 1 2 3 4 1 2 3 4 5 6 7 8 WARNING Exceeding the Maximum Torque Can Damage the Valve and Void the Warranty 3 ANSI 150 Flange 65 ft lbs 4 ANSI 150 Flange 70 ft lbs 6 ANSI 150 Flange 100 ft...

Страница 10: ...Kit for AFR actuator series PICCV CCV ZS SPBV 10 For NM AM GM NF AF and GK actuator series Ball Valves ZS SPBV 20 For dual mounted GM AF and GK actuator series ZS BVVS 0002 For LM actuator series on V...

Страница 11: ...SY3 230 VAC on off actuators Ball Valves Butterfly Valves EXT NSV B22 230 Battery backup system for SY1 SY3 230 VAC MFT actuators Ball Valves Butterfly Valves EXT NSV B03 120 Battery backup system fo...

Страница 12: ...inductive 250 VAC for LV SV EV and AVK series actuators Energy Valves ePIV Globe Valves SY 1000 FB01 Feedback potentiometer 1000 2 position factory installed option only Ball Valves Butterfly Valves S...