Page 6 

 

TLX640 Matrix Switch Product Manual          

thinklogical

 

Rev. H, February 2020

 

4.

 

Alarm, Inventory and Power Supply Status

 (TCP port 17600) 

  State of the alarm contacts 

  Card Inventory 

  Power Supply Status (internal TL use only) 

  Switch card temperature readings 

5.

 

I/O card data

 (TCP ports 17601 through 17640, 1 port per I/O card) 

  SFP installed bits 

  SFP TxDisable bits 

  SFP TxFault bits 

  SFP LOS bits 

  I/O card type 

  I/O card temperature 

  SFP serial ID data 

  SFP Diagnostic data 

6.

 

Service Request (LOS) Signaling

 (UDP port 17560) 

The  TLX640  can  broadcast  a  message  over  the  network  when  a  remote  receiver  requests  attention. 
When  enabled,  the  receiver  will  toggle  its  TX  pin,  causing  a  LOS  (loss  of  signal)  event to  occur  at  the 
matrix switch. When detected, the TLX640 broadcasts an 'Attention Request' message over the network. 
This message contains the IP address of the switch and the port number that detected the request. It is 
left up to an external system to detect, decode and act upon this request. 

  32-bits, matrix switch's primary IP address 

  16-bits, 0 for the Upper (or only) matrix switch chassis, 1 for the Lower matrix switch chassis 

  16-bits, port number (list starts from 1, not 0) 

  16-bits, key code in bits 0 

– 7, 0x00 and 0xff are ignored 

SNMP SUPPORT 

The TLX640 can be monitored via SNMP

 

S

imple 

N

etwork 

M

anagement 

P

rotocol 

(supports version V2c 

and  V3  USM).  Please  call  our  technical  support  staff  at 

1-203-647-8700

  for  downloadable 

MIB

 

M

anagement 

I

nformation 

B

ase

 

definition files. 

There are a few entries in the SNMP configuration file (

/etc/snmp/snmpd.conf

) that users may want 

to modify: 

 

syslocation

  

Text to aid in locating the unit 

 

syscontact

   

Name/Phone/email address of a contact 

 

trap2sink

    

IP address/name of a system to receive SNMP traps 

The default name used by trap2sink is '

snmp.trap

' and is defined in the file 

/etc/hosts

 as pointing to 

127.0.0.1. The easiest method to change the trap address is to modify the 

/etc/hosts

 entry and not 

change  the  trap2sink  setting  in  the  configuration  file.  You  may  have  multiple  trap2sink  entries  in  the 
configuration file to specify multiple trap destinations. 

NTP SUPPORT 

NTP, or 

Network Time Protocol

, is used to keep the internal clock on the switch set to the correct 

time.

 By enabling this service, users keep the switch

’s clock synchronized to an external time reference. 

To use the service, users must have a time-server running on their network or allow the switch to access 
a public time-server. NTP configuration is contained in the file 

/etc/ntp.conf

  

Details about NTP configuration may be found at: 

http://tldp.org/LDP/sag/html/basic-ntp-config.html

 

Содержание Thinklogical TLX640

Страница 1: ...Rev H February 2020...

Страница 2: ...U S A Telephone 1 203 647 8700 All trademarks and service marks are property of their respective owners Subject TLX640 10G Matrix Switch Product Manual Revision H February 2020 Website https www think...

Страница 3: ...ECTION 2 SET UP AND INSTALLATION 13 Contents 13 Unpacking the TLX640 13 Connecting to the TLX640 14 Ethernet Control 14 TLX640 DIP Switch Settings 14 Redundancy and Network Requirements 14 External Co...

Страница 4: ...Zealand 27 European Union 27 Declaration of Conformity 27 Standards with Which Our Products Comply 27 Supplementary Information 28 Product Serial Number 28 Connection to the Product 28 SECTION 4 THIN...

Страница 5: ...d NATO NIAPC Evaluation Scheme GREEN and the U S DoD DISA JITC UCR 2013 APL information assurance standards And Thinklogical Velocity products are the first system with both KVM and video matrix switc...

Страница 6: ...f the manual Note and Warning Symbols Throughout this manual you will notice certain symbols that bring your attention to important information These are Notes and Warnings Examples are shown below No...

Страница 7: ...paration between potential threats users and the target secure data is essential to a secure system design Thinklogical s system permits users to access sources up to 80 kilometers away with no perfor...

Страница 8: ...for replacement If you suspect a problem with the Interconnect Card call us at 203 647 8700 for assistance Thinklogical s TLX640 line replaceable modules include 2 Redundant Current Sharing Power Supp...

Страница 9: ...populated with modules THE CONTROLLER CARDS The hot swappable Controller Card connects the Matrix Switch to an External CPU The RS 232 serial port may be used for third party controller integration s...

Страница 10: ...can be set from 15 to 45 The default subnet used by the TLX640 is 192 168 13 xxx The user may use their own subnet by reconfiguring the switch s network startup This is detailed in the document Manua...

Страница 11: ...0 7 0x00 and 0xff are ignored SNMP SUPPORT The TLX640 can be monitored via SNMP Simple Network Management Protocol supports version V2c and V3 USM Please call our technical support staff at 1 203 647...

Страница 12: ...one DB9 DCE A straight cable is needed to connect to a PC not a null modem ASCII API RS232 Baud Rate 9600 Data Bits 8 Parity none Stop Bits 1 Flow Control XON XOFF Software DB9 DCE A straight cable is...

Страница 13: ...tics SFP Individual I O Cards list the ports as 1 through 20 on the TLX640 A blue LED located on each I O card indicates when power is ON to that card PORT NUMBERING The TLX640 can have a minimum of o...

Страница 14: ...12Gpbs asynchronous switch that can connect any input to any output of Thinklogical s TLX VX and MX Matrix Switches Video and Data signals are routed in both directions and the data stream is de multi...

Страница 15: ...Switch Card without shutting down the TLX640 The hot swappable feature allows easy replacement of a Switch Card without shutting down the TLX640 Card 8 Card 1 TLX640 Switch Cards TLX640 FEATURES Each...

Страница 16: ...nd the Controller Power 3 3V in both the Upper and Lower Card Cages is applied Warning KEEP THE DOOR CLOSED WHEN IN USE The TLX640 Front Door contains air flow baffles that are integral to the unit s...

Страница 17: ...00 1244 6 mm Depth 16 07 408 2 mm Width 17 16 435 9 mm Weight Fiber or CATx 132 0 lbs 59 9 kg Shipping Weight 160 0 lbs 72 6 kg Ports 20 x 20 min 640 x 640 max ENVIRONMENTAL Temperature Operating 0 to...

Страница 18: ...be mounted in a standard EIA 19 rack All physical connections to the product use industry standard connectors Non supplied cables that may be needed are commercially available All connections are fou...

Страница 19: ...ts are not possible then the control server will require two 2 network interfaces with one interface set to the static address 192 168 13 9 and dedicated to the TLX640 KVM Matrix Switch s while the ot...

Страница 20: ...n that allows it to communicate with both the Primary Controller and a server with the IP address 192 168 13 9 Without this interface the Back up Controller cannot take control of the switch Pluggable...

Страница 21: ...can extend up to a maximum of 400m and Single mode fiber can extend up to 80km T R T R LC LC Transmit Receive Handling Fiber optic Cable Unlike copper cabling fiber optic cable requires special handli...

Страница 22: ...trix Switch Product Manual thinklogical Rev H February 2020 TLX Extender Fiber Optic Cable Configurations SINGLE VIDEO MODULES DUAL VIDEO MODULES Note On Dual Video models SFPs 1 2 are Video 1 and SFP...

Страница 23: ...Cable Configurations There are currently several versions of CATx category 5 5a 6 6a etc cables on the market Thinklogical recommends using a minimum of CAT6 for your TLX KVM Matrix Switch and Extensi...

Страница 24: ...0 I O Card numbers the ports 1 through 20 An LED located on each card indi cates when power is applied to that card Input Output Port Numbering on the TLX640 At the bottom of the Lower Cage and at the...

Страница 25: ...S devices audio keyboard mouse etc are connected to the Receiver first using standard cables Power can then be applied to the unit The Receiver then connects to the TLX640 Receiver ports using fiber M...

Страница 26: ...and and must end with a carriage return CR and line feed LF or just a line feed LF The characters are not echoed The serial port is configured for 9600 baud 1 stop bit no parity and no flow control Th...

Страница 27: ...lt in timeout function therefore the PC should not be taken out of service for an extended period The timeouts can be set in increments of one second Typical timeouts are in the order of 10 seconds Or...

Страница 28: ...ned off on the TLX640 Remove the AC power cord s from the Matrix Switch or from the AC source for a complete system shut down Remove any cables LAN RS 232 Console etc from the Control Cards The Contro...

Страница 29: ...ed arrows right 5 Place the new module upright so that the four Status LEDs are at the bottom Grasp the module by the handles The card should slide in freely until it reaches the backplane connector A...

Страница 30: ...e card and start over 3 Once the module is completely seated hand tighten the thumbscrews Do not tighten the thumbscrews with a screwdriver How to Replace a Fan Tray The TLX640 uses three DC fans to m...

Страница 31: ...he backplane connector At this point use just enough force to firmly engage the card with the mating connector Ensure the locking mechanism snaps closed If the module does not slide easily into the co...

Страница 32: ...t Canadian Radiation Emitting Devices Act REDR C1370 IEC 60825 2001 Parts 1 and 2 Class 1 LASER Product Electromagnetic Interference FCC 47CFR Part 15 Subpart B 2013 Class A Industry Canada ICES 003 2...

Страница 33: ...in a commercial environment This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instruction manual may cause harmful interference...

Страница 34: ...urchase on most products Thinklogical and its suppliers disclaim all other warranties Please refer to your product invoice for the Warranty Terms Conditions Defect remedy shall be the repair or replac...

Страница 35: ...Page 30 TLX1280 Matrix Switch Product Manual thinklogical Rev H February 2020 APPENDIX A TLX640 QUICK START GUIDE...

Страница 36: ...Page 31 TLX1280 Matrix Switch Product Manual thinklogical Rev H February 2020 Appendix B Setting the DIP Switch Instruction...

Страница 37: ...Page 32 TLX1280 Matrix Switch Product Manual thinklogical Rev H February 2020 Appendix C FPGA Program Code Update Procedure...

Страница 38: ...chassis backplane wait 5 seconds then reconnect it 10 Wait for the crng init done message then connect the network cable to the Back up Controller Card and wait 10 seconds 11 Unplug the network cable...

Страница 39: ...Page 34 TLX1280 Matrix Switch Product Manual thinklogical Rev H February 2020...

Страница 40: ...used to manage the Matrix Switch must be physically protected and have suitable identification authentication mechanisms to ensure that only trusted administrators have access Thinklogical s TLX VX a...

Страница 41: ...ech marks character code 34 Lower case i character code 105 i Lower case o character code 111 o Comma character code 44 Carriage Return character code 13 CR Line Feed character code 10 LF The Restrict...

Страница 42: ...s the following This procedure will be disruptive to system connections 1 Update the Restricted Switching Table of the Primary Controller Card 2 Take the Primary Controller Card out of service by foll...

Страница 43: ...Matrix Switches Restricted Switching Priority Scheme The following example shows a priority scheme for four levels of security managed by one TLX Matrix Switch Restricted switching is configured via...

Страница 44: ...he Switch This file contains the port number and the partitions to which it belongs Example VX80 Matrix Switch with four distinct partitions Four partitions set up for secure routing and extension app...

Страница 45: ...p Controller Card for any errors in the Partition Table and correct them before implementing multiple levels of security classification domains on the same Matrix Switch using the Back Up Controller C...

Страница 46: ...e Password Security For security purposes the Switch defaults to using the Message Digest Algorithm MD5 and shadow passwords It is highly recommended that you DO NOT alter these settings If you select...

Страница 47: ...from the Red Network to the Black Network using the Restricted Switching feature For example the TLX Matrix Switch Network Diagram should be configured with the following csv file Direction Number Pr...

Страница 48: ...Page 43 TLX640 Matrix Switch Product Manual thinklogical Rev H February 2020 TLX640 10G Matrix Switch Secure Application...

Отзывы: