Information sheet  LioN-P multiprotocol

Release 1.2 04/2017

Содержание lumberg automation LioN-P 0980 ESL 300 Series

Страница 1: ...otocol Digital I O modules and IO Link Master 0980 ESL 390 121 0980 ESL 391 121 0980 ESL 392 121 0980 ESL 393 121 0980 ESL 390 121 DCU1 0980 ESL 393 121 DCU1 0980 ESL 390 111 0980 ESL 391 111 0980 ESL...

Страница 2: ...2 Information sheet LioN P multiprotocol Release 1 2 04 2017...

Страница 3: ...on 5 2 About the LioN P module series 6 3 Multiprotocol 7 4 Protocol settings for Digital I O modules 8 4 1 EtherNet IP PROFINET EtherCAT 8 4 1 1 EtherNet IP 9 4 1 2 PROFINET 10 4 1 3 EtherCAT 10 4 2...

Страница 4: ...Content 4 Information sheet LioN P multiprotocol Release 1 2 04 2017...

Страница 5: ...ontact us if you have any detailed questions on installing and starting up the devices We will be happy to help you Belden Deutschland GmbH Lumberg Automation Im Gewerbepark 2 58579 Schalksm hle Germa...

Страница 6: ...the costs for installation and maintenance They additionally enable easy quick extension The modules of the LioN P series have been substantially reduced in size compared with the well known LioN R f...

Страница 7: ...different environments Using rotary encoding switches at the bottom of the modules you can easily and conveniently set both the protocol and the address of the module if the protocol to be used suppor...

Страница 8: ...P E IP PROFINET P and EtherCAT EC 0980 ESL 390 121 0980 ESL 391 121 0980 ESL 392 121 0980 ESL 393 121 0980 ESL 390 121 DCU1 0980 ESL 393 121 DCU1 0980 ESL 390 111 0980 ESL 391 111 0980 ESL 392 111 098...

Страница 9: ...his way you restore the factory settings of the respective module How you perform the factory reset for your module is described in chapter Factory reset on page 10 If you position the rotary encoding...

Страница 10: ...the value of EC For more information use the LioN P EtherCAT Digital I O manual 4 2 Factory reset A factory reset restores the original factory settings and thus resets the changes and settings you h...

Страница 11: ...80 ESL 199 332 0980 ESL 398 121 0980 ESL 399 121 The multiprotocol modules have a total of three rotary encoding switches With the first rotary encoding switch x100 you set the protocol by using the c...

Страница 12: ...ter Factory reset on page 13 If you position the rotary encoding switch in a manner that is invalid the device signals this to you with a blink code the BF MS LED blinks in red three times 5 1 1 Ether...

Страница 13: ...nd settings you have made up to that point It also resets the protocol selection To perform a factory reset set the first rotary encoding switch x100 to 9 the second x10 to 7 and the third x1 also to...