13.1 General
13 Technical data
13.1 General
Protection class
(Only applies if the connectors are
screwed together or if protective
caps are used.)
IP65
IP67
IP69K
0980 XSL 3912-121...
-40° F to +158° F
(-40° C to +70° C)
0980 LSL 3x11-121...
Ambient temperature (during
operation and storage)
0980 LSL 3x10-121...
-4° F to +140° F
(-20° C to +60° C)
Weight
LioN-X 60 mm
ca. 500 gr.
Ambient moisture
max. 98% RH
(for UL certification: max. 80% RH)
Housing material
Die-cast zinc
Surface finish
frosted nickel
Flammability class
UL 94 (IEC 61010)
Vibration resistance (oscillation)
DIN EN 60068-2-6 (2008-11)
15 g / 5-500 Hz
Shock resistance
DIN EN 60068-2-27 (2010-02)
50 g / 11 ms
+/- X,Y,Z
M4 fixing screws
1 Nm
M4 ground connection
1 Nm
Fastening torques
M12 connector
0.5 Nm
Permitted cables
Ethernet cables according to IEEE 802.3, min. CAT 5 (shielded)
max. length of 100 m
Table 36: General information
2
Not under UL investigation.
Manual EtherCAT®
Version 1.1 04/2021
138