32
Installation SPIDER-SL
Release 06 01/2020
6
Technical data
General technical data
Dimensions
W × H × D
SPIDER Standard Line
See “Dimension drawings” on
page 33.
Power supply
1 voltage input
3-pin terminal block
Safety extra-low voltage (SELV)
Rated voltage range
12 V DC ... 24 V DC
Class 2
Voltage range incl. maximum
tolerances
9.6 V DC ... 32 V DC
Power loss buffer
10 ms at 20.4 V DC
Back-up fuse
2 A ... 4 A, slow blow
Peak inrush current
4 A
Potential
difference between
input voltage and
ground connection
Potential difference from
incoming v24 V DC
+32 V DC
Potential difference from
incoming voltage, ground
-32 V DC
Climatic conditions
during operation
Ambient air temperature
a
a. Temperature of the ambient air at a distance of 2 in (5 cm) from the device
+32 °F ... +140 °F (0 °C ... +60 °C)
Derating
b
b. For device variant SPIDER SL-40-06T1O6O699SZ9HHHH, the maximum permitted
ambient air temperature has to be reduced to 122 °F (50 °C).
Humidity
10 % ... 95 %
(non-condensing)
Air pressure
min. 795 hPa (+6562 ft; +2000 m)
Climatic conditions
during storage
Ambient air temperature
a
-40 °F ... +158 °F (-40 °C ... +70 °C)
Humidity
10 % ... 95 %
(non-condensing)
Air pressure
min. 700 hPa (+9842 ft; +3000 m)
Pollution degree
2
Protection classes Degree of protection
IP30