![Belden Hirschmann Rail Switch Power Lite Скачать руководство пользователя страница 30](http://html.mh-extra.com/html/belden/hirschmann-rail-switch-power-lite/hirschmann-rail-switch-power-lite_user-manual_2725676030.webp)
Spanning Tree
30
UM RedundConfig RSPL
Release 2.0 02/2013
If the device working as the root is inoperable and another device takes over
its function, the
Max Age
setting of the new root bridge determines the
maximum number of devices allowed in a branch.
Note:
The RSTP standard dictates that all the devices within a network work
with the (Rapid) Spanning Tree Algorithm. If STP and RSTP are used at the
same time, the advantages of faster reconfiguration with RSTP are lost in the
network segments that are operated in combination.
A device that only supports RSTP works together with MSTP devices by not
assigning an MST region to itself, but rather the CST (Common Spanning
Tree).