5
EMC: emitted interference - line related / Power Port DC
EN50155
Class A
0.15 MHz to 0.5 MHz, max. 99 dB
(µV)/m, quasi-peak
0.5 MHz to 30 MHz, max. 93 dB
(µV)/m, quasi-peak
EMC: interference immunity- radiated
IEC/EN61000-4-3
Electromagnetic field
80 to 2700 MHz
20 V/m
EMC: interference immunity- line related
IEC/EN61000-4-2
Electrostatic discharge
Contact discharge
6 kV
Air discharge
8 kV
IEC/EN61000-4-4
Fast transients (burst)
Power
input
4 kV
IEC/EN61000-4-5
Voltage surges
Power input
1 kV line / line
Power input
2 kV line/earth
IEC/EN61000-4-6
Line-conducted interference voltages
150 kHz to 80 MHz
10 V
Mechanical components
Dimensions - without cables (W x H x L)
115 mm x 65 mm x 240 mm
Weight
3,100 g
Housing material
Aluminum, UL94-V0
Casting compound
Polyurethane
Vibration resistance
IEC60068-2-6 Test Fc
Test level according to IEC61131-2
EN61373, category 1
Class A (broadband noise), installation according to EN50155
Shock resistance
IEC60068-2-27 Test Ea
Test level according to IEC61131-2
EN61373, category 1
Class A (broadband noise), installation according to EN50155
Scope of delivery
Power supply unit incl. ferrite on secondary cable, startup instructions and dispatch note for returning product