44
Installation BAT-R
Release 17 12/2020
For
every
supply voltage to be connected, perform the following steps:
Remove the terminal connector from the device.
Connect the wires according to the pin assignment on the device with the
clamps.
Fasten the wires in the terminal block by tightening the terminal screws.
2.5.4
Signal contact
For every signal contact to be connected, make sure the following
requirements are met:
The electrical wires are voltage-free.
The connected voltage is limited by a current limitation device or a fuse.
Observe the electrical threshold values for the signal contact.
See “General technical data” on page 58.
Connect the wires according to the pin assignment on the device with the
clamps.
Mount the terminal block on the device using screws.
2.6
Operating the device
By connecting the supply voltage via a terminal block or a twisted pair cable
(Power over Ethernet), you start the operation of the device.
2.6.1
Connecting the power supply through a terminal
block
Relevant for North America:
The torque for tightening the supply voltage terminal block on the device is
4.5 lb-in (0.51 Nm).
The torque for tightening the terminal block for the signal contact on the
device is 3 lb-in (0.34 Nm).
WARNING
ELECTRIC SHOCK
Before connecting the electrical wires,
always
verify that the requirements
listed are complied with.
See “Requirements for connecting electrical wires” on page 11.
See “Requirements for connecting the supply voltage” on page 12.
Failure to follow this instruction can result in death, serious injury, or
equipment damage.