58
Installation BAT-R
Release 17 12/2020
10 Technical data
10.1
General technical data
Weight
Device variants featuring supply voltage with
characteristic value C (24 V DC ... 48 V DC) or K
(60 V DC ... 250 V DC / 110 V AC ... 230 V AC,
50 Hz ... 60 Hz)
approx. 52.91 oz
(1500 g)
Device variants featuring supply voltage with
characteristic value W (24 V DC)
and approvals 1 with characteristic value I, M
or 9
approx. 42.33 oz
(1200 g)
Device variants featuring supply voltage with
characteristic value W (24 V DC)
and approvals 1 with characteristic value K
approx. 45.86 oz
(1300 g)
Supply voltage
with the
characteristic
value C
Class 2
Rated voltage range DC:
24 V DC ... 48 V DC
Voltage range DC incl.
maximum tolerances:
18 V DC ... 60 V DC
Connection type
2-pin terminal block
Power loss buffer
>10 ms at 20.4 V DC
Overload current protection on
the device
Non-replaceable fuse
Back-up fuse for each voltage
input when supply is via 2
inputs
Nominal rating:
Characteristic:
Max. 1.5 A
slow blow
Back-up fuse when using
1 voltage input
a
Nominal rating:
Characteristic:
Max. 3.15 A
slow blow
Back-up fuse when installed in
a fire enclosure according to
IEC 60695-11-10
Nominal rating:
Characteristic:
Max. 6.3 A
slow blow
Peak inrush current
14 A
Supply voltage
with the
characteristic
value K
Rated voltage range AC:
110 V AC ... 230 V AC, 50 Hz ... 60 Hz
Voltage range AC incl.
maximum tolerances:
88 V AC ... 265 V AC, 47 Hz ... 63 Hz
Rated voltage range DC:
60 V DC ... 250 V DC
Voltage range DC incl.
maximum tolerances:
48 V DC ... 320 V DC
Connection type
3-pin terminal block
Power loss buffer
>10 ms at 98 V AC
Overload current protection on
the device
Non-replaceable fuse
Back-up fuse for each voltage
input
Nominal rating:
Characteristic:
2.5 A
slow blow
Peak inrush current
14 A
Содержание Hirschmann OpenBAT BAT-R