Belden HIRSCHMANN ACA21 Series Скачать руководство пользователя страница 16

16

Startup instructions ACA21.../ACA22...

Release 05 07/2021

Figure

Pin

Function

1

U

in

2

CC1

3

 Data

4

Ground (GND)

5

+  Data

Table 3:

Pin assignment of the plug of the following storage medium: ACA22-M12-
C (EEC)

1

2

3

4

5

Содержание HIRSCHMANN ACA21 Series

Страница 1: ...A21 ACA22 Release 05 07 2021 Technical support https hirschmann support belden com Startup instructions AutoConfiguration Adapter ACA21 USB EEC ACA22 USB EEC ACA21 M12 EEC ACA22 M12 EEC ACA22A ACA22 USB C EEC ACA22 M12 C EEC ...

Страница 2: ...use The performance features described here are binding only if they have been expressly agreed when the contract was made This document was produced by Hirschmann Automation and Control GmbH according to the best of the company s knowledge Hirschmann reserves the right to change the contents of this document without prior notice Hirschmann can give no guarantee in respect of the correctness or ac...

Страница 3: ...tup instructions ACA21 ACA22 Release 05 07 2021 3 Contents Important information 4 Safety instructions 6 Description 13 Installation 14 Pin assignments 15 Operation 17 Technical Data 18 A Further support 21 ...

Страница 4: ...sible injury or death If this symbol is displayed in addition to a safety instruction of the type Danger or Warning it means that there is a danger of electric shock and failure to observe the instructions will inevitably result in injury This symbol indicates the danger of hot surfaces on the device In connection with safety instructions non observance of the instructions will inevitably result i...

Страница 5: ...Startup instructions ACA21 ACA22 Release 05 07 2021 5 NOTICE NOTE provides information about procedures that do not involve the risk of injury ...

Страница 6: ...f is insufficient there is a potential risk of torsion contact problems and creeping interruptions Relieve the connection points of cables and lines from mechanical stress Design strain reliefs in such a way that they help prevent any mechanical damage to cables wires or conductors caused by external influences or their own weight To help prevent damage to device connections connectors and cables ...

Страница 7: ...DNR In addition the host device shall meet the Entity Parameter requirements as prescribed in the Control Drawing 000163850DNR in this present document See Control Drawing 000163850DNR on page 9 WARNING EXPLOSION HAZARD DO NOT DISCONNECT EQUIPMENT UNLESS POWER HAS BEEN SWITCHED OFF OR THE AREA IS KNOWN TO BE NON HAZARDOUS WARNING EXPLOSION HAZARD SUBSTITUTION OF ANY COMPONENTS MAY IMPAIR SUITABILI...

Страница 8: ...re Code T4 Ta 40 C to 70 C 40 F to 158 F Non incendive only in Ex Zone 2 when installed per Control Drawing 000163850DNR In addition the host device shall meet the Entity Parameter requirements as prescribed in the Control Drawing 000163850DNR in this present document See Control Drawing 000163850DNR on page 9 Special conditions for safe use The equipment shall only be used in an area with maximum...

Страница 9: ... Power supply contacts ACA21 USB EEC ACA22 USB EEC and ACA22A with nonincendive field wiring parameters The USB contacts pin 1 and pin 4 are dependent on the following ENTITY PARAMETERS Vmax or Ui lmax or Ii Ci Li 5 5 V 1 25 Adc 6 0 μF 400 nH USB Data contacts Entity Parameters only to apply for ACA21 USB EEC ACA22 USB EEC and ACA22A which are inividually labelled Temperature Code T4 Ambient Tempe...

Страница 10: ...e 2014 34 EU The equipment shall only be used in an area of not more than pollution degree 2 as defined in IEC 60664 1 The product shall be installed in a suitable enclosure providing a degree of protec tion of at least IP54 in accordance with EN 60079 0 taking into account the envi ronmental conditions under which the product will be used Note Applied parameter designations under the conditions o...

Страница 11: ...lusively to the device variants labeled with an ATEX certificate number See Use in Explosive Atmospheres Zone 2 According to European Directive 2014 34 EC on page 8 In accordance with the above named EU directive s the EU conformity declaration will be at the disposal of the relevant authorities at the following address Hirschmann Automation and Control GmbH Stuttgarter Str 45 51 72654 Neckartenzl...

Страница 12: ...12 Startup instructions ACA21 ACA22 Release 05 07 2021 Note The assembly guidelines provided in these instructions must be strictly adhered to in order to observe the EMC threshold values ...

Страница 13: ...uration data and software of the Hirschmann Industrial Ethernet host devices USB compatibility of the storage medium ACA21 ACA22 Further information Technical Data on page 18 Storage medium Software ACA21 Classic compatible HiOS HiSecOS Enabling the compatibility mode on the device is required ACA22 Classic HiOS HiSecOS compatible ...

Страница 14: ...Note Note that upon restart the host device depending on its configuration adopts the configuration saved on the ACA21 ACA22 storage medium The status of the storage medium in the graphical user interface or in the Command Line Interface tells you if the configuration on the ACA21 ACA22 storage medium corresponds with the configuration on the host device ...

Страница 15: ...GND Table 1 Pin assignment of the USB A interface Figure Pin Function 1 Uin 2 3 Data 4 Ground GND 5 Data Table 2 Pin assignment of the plug of the following storage media ACA21 M12 EEC ACA22 M12 EEC 1 2 4 3 GND V BUS D D CC2 V BUS GND Name Name Pin Pin B12 B11 B10 B9 B8 B7 B6 B5 B4 B3 B2 B1 A1 A2 A3 A4 A5 A6 A7 A8 A9 A10 A11 A12 GND V BUS CC1 D D V BUS GND 1 2 3 4 5 ...

Страница 16: ... Startup instructions ACA21 ACA22 Release 05 07 2021 Figure Pin Function 1 Uin 2 CC1 3 Data 4 Ground GND 5 Data Table 3 Pin assignment of the plug of the following storage medium ACA22 M12 C EEC 1 2 3 4 5 ...

Страница 17: ... user interface or the Command Line Interface on the ACA21 ACA22 storage medium and the flash memory of the host device simultaneously Transferring the configuration data from the storage medium Upon restart the host device adopts the configuration data saved on the ACA21 ACA22 storage medium and saves them permanently in the flash memory Updating the software For more information refer to the Use...

Страница 18: ...22 USB EEC 512 MB ACA22 M12 EEC ACA22 M12 C EEC ACA22A ACA22 USB C EEC Connection type ACA21 USB EEC USB A plug ACA22 USB EEC ACA22A ACA22 USB C EEC USB C plug ACA21 M12 EEC 5 pin A coded M12 plug ACA22 M12 EEC ACA22 M12 C EEC Dimensions ACA21 USB EEC 93 mm 29 mm 15 mm 3 66 in 1 14 in 0 59 in ACA22 USB EEC ACA21 M12 EEC ACA22 M12 EEC ACA22A 46 mm 16 mm 8 mm 1 81 in 0 63 in 0 31 in ACA22 USB C EEC ...

Страница 19: ...a a Temperature of the ambient air at a distance of 5 cm 2 in from the device 40 C 70 C 40 F 158 F Humidity 10 95 non condensing Air pressure min 795 hPa 2000 m 6562 ft max 1060 hPa 400 m 1312 ft Climatic conditions during storage Ambient air temperaturea 40 C 85 C 40 F 185 F Humidity 10 95 non condensing Air pressure min 700 hPa 3000 m 9842 ft max 1060 hPa 400 m 1312 ft EMC and immunity Immunity ...

Страница 20: ...s Part 7 Equipment protection by increased safety e EN 60079 11 Explosive atmospheres Part 11 Equipment protection by intrinsic safety i EN 61131 2 Programmable controllers Part 2 Equipment requirements and tests FCC 47 CFR Part 15 Code of Federal Regulations IEC EN 61850 3 Communication networks and systems for power utility automation Part 3 General requirements IEEE 1613 IEEE Standard Environme...

Страница 21: ... competitors on three counts with its complete range of innovative services Consulting incorporates comprehensive technical advice from system evaluation through network planning to project planning Training offers you an introduction to the basics product briefing and user training with certification You find the training courses on technology and products currently available at https www belden ...

Страница 22: ......