15
MV-831
User Manual
MV-831 General Monitoring Mode
Various monitoring combinations are possible by changing some router configuration
settings, as described in Table 1-5.
Fig. 1-10: MV-831 General Monitoring Mode
Monitor a
combination
of:
• MV-831
module outputs,
• MV-831
module inputs, and
• Router sources.
(See Table 1-5.)
Table 1-5: MV-831 General Monitoring Mode Settings
Router Configuration Setting
Signals at MV-831 Module
Redundant
Crosspoint
Enable
Main Output
Follow
Multiviewer Block Input Signals
MV-831 Router Output Signals
1 to 24
25 to 48
24-off
Enabled
Enabled
MV-831
Output
(Redundant)
MV-831
Input
Same as MV block inputs 1 to 24
from Main/Redundant Crosspoint
Disabled
Enabled
MV-831
Output
(NOT Redundant)
Router
Source
(re-purposes a
destination of the
second crosspoint, see
Note 1)
Same as MV block inputs 1 to 24
but from Main-only Crosspoint
Disabled
Disabled
MV-831
Input
From Main-only Crosspoint
Enabled
Disabled
MV-831
Output
(Redundant)
From Main/Redundant Crosspoint
Note 1:
When the second video crosspoint is re-purposed, make routes with the crosspoint by using higher
destination port numbers. See Appendix B