GUIDE TO INSTALLATION AND OPERATION
12
| HDA-3961
2.
The center portion of the iControl graphic interface window contains a series of control and information panels,
selected by tabs.
Click on a tab to display the associated panel.
Each of these panels is described individually in the following sections.
3.
The Load Factory button is always visible at the bottom of the panel. Click the
Load Factory
button to reset all
parameters on this HDA-3961 card to factory default values.
The factory default values are shown underlined in the menus found in the Annex to this document, beginning
on page 22.
5.2 The Input panel
This panel allows the user to select the input that will be processed
through the available channels in the HDA-3961.
Two channels are available. The rear panel may have one or two electrical
inputs, and may have two optical inputs. Channel B will be greyed out if no
signal is available for it.
Input Config
Select the input for Channel A and Channel B, using the radio buttons.
1- Select Operating Mode (DUAL/SINGLE)
2- DUAL mode:
a. Select Electrical A or Optical A for channel A
b. Select Electrical B or Optical B for channel B
3- SINGLE mode:
a. Select input: Electrical A, Electrical B, Optical A or Optical
B if available.
Figure 3.4 Input panel
– HDA-3961