900µm TIGHT BUFFER/250µm - INSTALLATION GUIDE

Fusion Splicer setup:

 1.

    Follow the manufacturer’s 

instructions:

 A.

   Perform calibration and arc 

check.

 B.

   Select the appropriate splicing 

mode based on fiber type 

(

SM

 or 

MM

).

 C.

   If applicable remove the left 

fiber holder.

 D.

   Set the heating mode by 

referring to the heat setting 

table on the first page.

2.

  Just before use, open the sealed 

bag of the FX Fusion Splice-On SC 
Connector Kit.

3.

  Open the clamshell carefully by 

lifting the top cover and sliding 

your finger toward both sides 

(

right

 and 

left

). 

Clamshell open:

Splice protection sleeve 

with spring

Rear housing with boot

Connector front 

housing

Ferrule stub assembly
Ferrule stub’s 

dust cap

Содержание FX FUSION LC CONNECTOR

Страница 1: ...m TIGHT BUFFER 250 m INSTALLATION GUIDE Materials Fusion Splicer and Cleaver FX Fusion Splice On Installation Tool Kit FX Fusion Splice On LC Connector Kit FX Fusion Splice Holder FX Fusion Splice On...

Страница 2: ...ating activities Maintain the fiber components clean as your working area Clean end face with alcohol wipes and then dry wipe as cleaning procedures Instructions for Cleaver If the cleaver does not wo...

Страница 3: ...If applicable remove the left fiber holder D Set the heating mode by referring to the heat setting table on the first page 2 Just before use open the sealed bag of the FX Fusion Splice On SC Connecto...

Страница 4: ...r 5 Place the ferrule stub assembly in the FX Fusion splice holder and push it to the right up to the position shown below NOTE It is recommended to remove the holder from the splicer 6 Load the splic...

Страница 5: ...ble should be stripped about 5mm at a time IMPORTANT When stripping the buffer and the 250 m coating must be completely removed to allow to cleave the fiber 10 Clean the fiber 11 Cleave the fiber at 1...

Страница 6: ...e fusion splicer NOTE The placement of the end face is important Fibers end face should be located in between the V groove and electrodes as shown 13 Perform the fusion 14 Bring the splice protection...

Страница 7: ...red 17 Place the cable assembly in the splicer heater and follow the manufacturer s instructions and Belden s heat settings Heat the splice protection sleeve 18 Remove the cable assembly from the heat...

Страница 8: ...ONNECTOR PX106498 EN REV C Page 8 of 8 900 m TIGHT BUFFER 250 m INSTALLATION GUIDE 20 Align the rear housing tabs with the front housing cutouts and assemble the parts together 21 Cut the excess of th...

Отзывы: