background image

Installation MTS2600/2700/2800 

Release 01 12/2021 

Technical support 

https://hirschmann-it-support.belden.com

 

 

 

 

 

 

User manual 

Installation 
MAMMUTHUS ACCESS LAYER & DISTRIBUTION LAYER 
SWITCH   
MTS2600/2700/2800 family 
MAMMUTHUS POWER MODULE – MTM2700-PSU500/PSU120 
MAMMUTHUS MEDIA MODULE – MTM2700-2X 

 

 

MTS2624-4X-B

 

 

MTS2724-4X-FP-S

 

 

MTS2724-6X-MP-E

 

 

MTS2748-6X-MP-E

 

 

 

 

Содержание 942999831

Страница 1: ...s hirschmann it support belden com User manual Installation MAMMUTHUS ACCESS LAYER DISTRIBUTION LAYER SWITCH MTS2600 2700 2800 family MAMMUTHUS POWER MODULE MTM2700 PSU500 PSU120 MAMMUTHUS MEDIA MODULE MTM2700 2X MTS2624 4X B MTS2724 4X FP S MTS2724 6X MP E MTS2748 6X MP E ...

Страница 2: ... that you make a copy of the software for your own use The performance characteristics described herein shall be binding only upon the express consent of the parties at the time of signing the contract This paper is produced by Belden within its capacity Belden reserves the right to change the contents of this manual without prior notice Belden does not guarantee the correctness or accuracy of the...

Страница 3: ... MP E 25 1 3 5 MTS2824 4X S 26 1 3 6 MTS2824 6X E 27 1 3 7 MTS2824F 4X S 28 1 3 8 MTS2832TF 4X E 29 1 3 9 MTS2848 6X E 30 1 3 10 MTS2848 6X S 31 1 3 11 Power module 32 1 3 12 Media module 33 1 4 Power supply 34 1 5 Ethernet port 35 1 5 1 1000 Mbit s F O port 35 1 5 2 10 Gbit s F O port 35 1 5 3 10 100 1000 Mbit s twisted pair port 35 1 5 4 PoE support 35 1 5 5 Out of band management port 36 1 6 Di...

Страница 4: ...47 2 7 Filling out the inscription Label 48 3 Making basic settings 49 4 Monitor ambient air temperature 50 5 Maintenance and repair 51 6 Disassembly 52 6 1 Removing the power module 52 6 2 Removing the media module 52 6 3 Removing the SFP transceiver 53 6 4 Removing the device 54 6 4 1 Removing the device from a vertical flat surface 54 6 4 2 Removing the device from the switch cabinet 54 7 Techn...

Страница 5: ...ay appear throughout this documentation or on the device These notes warn of potential hazards or call attention to information that clarifies or simplifies a procedure Symbol explanation This is a general warning symbol This symbol alerts you to potential personal injury hazards Observe all safety notes that follow this symbol to avoid possible injury or death If this symbol is displayed in addit...

Страница 6: ...6 Installation MTS2600 2700 2800 Release 01 12 2021 NOTICE provides information about procedures that do not involve the risk of injury NOTICE ...

Страница 7: ...aintenance procedures Before connecting any cable read this document and the safety instructions and warnings Operate the device with undamaged components exclusively The device is free of any service components In case of a damaged or malfunctioning device turn off the supply voltage and return the device to Hirschmann IT for inspection Qualification requirements for personnel Only allow qualifie...

Страница 8: ...kaging to assure it is sealed and not tampered by unauthorized party Verify serial number of delivered products to make sure it is unified with a hardcopy serial number list provided by manufacturer If it is necessary please contact Belden representative to obtain a softcopy serial number list from manufacturer for double check Requirements for connecting electrical wires Before connecting the ele...

Страница 9: ...e conductor and then the power supply voltage Supply with DC voltage The wire diameter of the power supply cable is at least 1 mm North America AWG16 on the supply voltage input Supply with AC voltage The wire diameter of the power supply cable is at least 0 75 mm North America AWG18 on the supply voltage input The cross section of the ground conductor is the same size as or bigger than the cross ...

Страница 10: ...hat there is at least one available rack space that is approximately 5 cm 2 in above the device to allow heat to escape through the enclosure of the device If you operate the device in a 19ʺ switch cabinet install the slide rails to support the weight of the device Installation site requirements Operate the device at the specified ambient temperature temperature of the ambient air at a distance of...

Страница 11: ... making available on the market of electrical equipment designed for use within certain voltage limits In accordance with the above named EU directive s the EU conformity declaration will be at the disposal of the relevant authorities at the following address Hirschmann Automation and Control GmbH Stuttgarter Str 45 51 72654 Neckartenzlingen Germany You find the EU conformity declaration as PDF fi...

Страница 12: ...uding interference that may cause undesired operation This device has been tested and found to comply with the limits for a class A digital device pursuant to part 15 of the FCC Rules These limits are designed to provide reasonable protection against interference with the device when used in commercial environments This device generates uses and can radiate radio frequency energy and if not instal...

Страница 13: ...e description safety instructions a description of the display and the other information that you need to install the device Documentation mentioned in the User Manual Installation that is not supplied with your device as a printout can be found as PDF files for downloading on the Internet at https catalog belden com ...

Страница 14: ...14 Installation MTS2600 2700 2800 Release 01 12 2021 Key The symbols used in this manual have the following meanings Listing Work step Subheading ...

Страница 15: ...n provide up to 30 W power for PoE PD equipment many L2 L3 functions and security functions can support complex network applications Modular power supplies can provide fast field maintenance FRU and the equipment can ensure normal operation under the environment of 55 131 MTS2800 switch provides a complete set of access and convergence solutions and all models have redundant power configuration Th...

Страница 16: ...16 Installation MTS2600 2700 2800 Release 01 12 2021 MTS2724 6X MP E MTS2748 6X MP E MTS2824 4X S MTS2824 6X E MTS2824F 4X S ...

Страница 17: ...Installation MTS2600 2700 2800 Release 01 12 2021 17 MTS2848 6X E MTS2832TF 4X E MTS2848 6X S ...

Страница 18: ...0 PSU120 MTM2700 PSU500 Note MTM2700 PSU120 and MTM2700 PSU500 can only be used in MTS2724 6X MP E MTS2748 6X MP E You may choose 1 or 2 power modules with the same input voltage LV Ethernet power supply Power modules are provided as accessories See Order number on Page 75 ...

Страница 19: ...2700 2800 Release 01 12 2021 19 Media module MTM2700 2X Note MTM2700 2X can only be used in MTS2724 6X MP E MTS2748 6X MP E You can select 1 media module Media modules are provided as accessories See Order number on Page 75 ...

Страница 20: ...P E 48 FE GE POE POE 4 1 10 Gbit s SFP slot 1 extend media module slot 2 modular power supply unit slot advanced software 942999846 MTS2832TF 4X E 24 100 1000 Mbit S SFP slot 8 FE GE TX 4 1 10 Gbit s SFP slot fixed redundant power supply advanced software 942999845 MTS2824F 4X S 24 100 1000 Mbit s SFP slot 4 1 10 Gbit s SFP slot fixed redundant power supply basic software 942999844 MTS2824 4X S 24...

Страница 21: ... DC 120 W power module AC input 100 V AC 240 V AC 2 A output 12 V DC 10 A No PoE support 942999833 MTM2700 PSU500 AC DC 500 W power module AC input 100 V AC 240 V AC 7 A output 12 V DC 10 A 53 5 V DC 7 A PoE support 1 2 3 Media module Order number Product code Description 942999836 MTM2700 2X MTS 2700 media module 2 1 10 Gbit s SFP slot ...

Страница 22: ... 4X B Figure 1 Front view 1 Gigabit Electrical Interface Status LED 2 Gigabit Electrical Interface 3 10 Gigabit Optical Interface 4 USB Interface 5 Console Port 6 Device Status LED 7 Reset Button press and hold for 5 seconds to restart the machine 8 AC Power Socket 9 Grounding Screw ...

Страница 23: ...t Electrical Interface Status LED 2 Gigabit Electrical Interface with POE function 3 10 Gigabit Optical Interface 4 USB Interface 5 Console Port 6 Device Status LED 7 Reset Button press and hold for 5 seconds to restart the machine Figure 3 Rear view 1 AC Power Socket 2 AC Power Socket 3 Grounding Screw ...

Страница 24: ...nt view 1 Gigabit Electrical Interface Status LED 2 Gigabit Electrical Interface with POE function 3 10 Gigabit Optical Interface 4 USB Interface 5 Console Port 6 Device Status LED Figure 5 Rear view 1 Interface Card Slot 2 Modular Power Supply 1 3 Modular Power Supply 2 4 Grounding Screw ...

Страница 25: ...nt View 1 Gigabit Electrical Interface Status LED 2 Gigabit Electrical Interface with POE function 3 10 Gigabit Optical Interface 4 USB Interface 5 Console Port 6 Device Status LED Figure 7 Rear view 1 Interface Card Slot 2 Modular Power Supply 1 3 Modular Power Supply 2 4 Grounding Screw ...

Страница 26: ...1 Gigabit Electrical Interface Status LED 2 Gigabit Electrical Interface 3 10 Gigabit Optical Interface 4 USB Interface 5 Console Port 6 Device Status LED 7 Reset Button press and hold for 5 seconds to restart the machine Figure 9 Rear view 1 AC Power Socket 2 AC Power Socket 3 Grounding Screw ...

Страница 27: ... Interface 2 Console Port 3 Gigabit Electrical Interface Status LED 4 Gigabit Electrical Interface 5 Air Inlet of the Device 6 10 Gigabit Optical Interface Status LED 7 10 Gigabit Optical Interface 8 Device Status LED Figure 11 Rear view 1 Air Outlet of the Device 2 AC Power Socket 3 Grounding Screw ...

Страница 28: ...t of the Device 2 Gigabit Optical Interface Status LED 3 Gigabit Optical Interface 4 10 Gigabit Optical Interface 5 USB Interface 6 Console Port 7 Device Status LED 8 Reset Button press and hold for 5 seconds to restart the machine Figure 13 Rear view 1 AC Power Socket 2 AC Power Socket 3 Grounding Screw ...

Страница 29: ...terface Status LED 2 Gigabit Optical Interface 3 Gigabit Electrical Interface Status LED 4 Gigabit Electrical Interface 5 10 Gigabit Optical Interface Status LED 6 10 Gigabit Optical Interface 7 Console Port 8 USB Interface 9 Device Status LED Figure 15 Rear view 1 AC Power Socket 2 AC Power Socket 3 Grounding Screw ...

Страница 30: ... Interface 2 Console Port 3 Gigabit Electrical Interface Status LED 4 Gigabit Electrical Interface 5 Air Inlet of the Device 6 10 Gigabit Optical Interface Status LED 7 10 Gigabit Optical Interface 8 Device Status LED Figure 17 Rear view 1 Air Outlet of the Device 2 AC Power Socket 3 Grounding Screw ...

Страница 31: ... Interface 2 Console Port 3 Gigabit Electrical Interface Status LED 4 Gigabit Electrical Interface 5 Air Inlet of the Device 6 10 Gigabit Optical Interface Status LED 7 10 Gigabit Optical Interface 8 Device Status LED Figure 19 Rear view 1 Air Outlet of the Device 2 AC Power Socket 3 Grounding Screw ...

Страница 32: ...32 Installation MTS2600 2700 2800 Release 01 12 2021 1 3 11 Power module Figure 20 Front view 1 Input Status LED 2 Output Status LED 3 Handle 4 Air Outlet of the Device 5 Power Switch 6 AC Power Socket ...

Страница 33: ...Installation MTS2600 2700 2800 Release 01 12 2021 33 1 3 12 Media module Figure 21 Front view 1 Anti Loosening Screw 2 Device Status LED 3 Gigabit Electrical Interface 4 Air Outlet of the Device ...

Страница 34: ... Installation MTS2600 2700 2800 Release 01 12 2021 1 4 Power supply You may use the power module to supply voltage to the device For information about connecting supply voltage See Power module on page 21 ...

Страница 35: ... s full duplex when 10 Gbit s Ethernet QSFP transceiver is used 1 Gbit s full duplex when Gbit Ethernet SFP transceiver is used 1 5 3 10 100 1000 Mbit s twisted pair port This port is an RJ45 socket The 10 100 1000 Mbit s twisted pair port allows you to connect network components according to the IEEE 802 3 10BASE T 100BASE TX 1000BASE T standard This port supports Auto negotiation Auto polarity A...

Страница 36: ...of band management port This port is an RJ45 socket The port allows you to connect network components according to IEEE 802 3 10BASE T 100BASE TX This port supports Auto negotiation 100 Mbit s half duplex 100 Mbit s full duplex 10 Mbit s half duplex 10 Mbit s full duplex The port allows you to manage the device and upload configuration through the following protocols SNMP SSH Telnet FTP See Comman...

Страница 37: ... to the system running Power light PWR Green ON indicating all in place power modules are working normally OFF indicating an exception to the in place power modules Fan indicator FAN Green ON indicating all fan modules on the equipment are working normally OFF indicating an exception to at least one fan module on the equipment STACK indicator STACK Green Flashing indicating stacking function is en...

Страница 38: ...ng on serial port DC0 interface indicator 1000 Mbit s RJ45 self contained yellow LED OFF indicating DC0 works at 10 100 Mbit s or is unlinked ON indicating DC0 works at 1000 Mbit s ACT RJ45 Build in green LED OFF indicating DC0 interface is unlinked ON indicating DC0 interface is linked with no data sending and receiving Flashing indicating DC0 interface is linked with data sending and receiving P...

Страница 39: ...ection of external management station VT100 terminal or PC with corresponding terminal emulation This enables you to set up a connection to the Command Line Interface CLI and to the System Monitor 1 7 2 USB interface The switch provides 2 serial ports EIA TIA 232 and Micro USB 2 0 This serial ports allows the users to configure the switch using the PC or laptop equipped with RS 232 serial port or ...

Страница 40: ...he data cables Filling out the inscription Label 2 1 Checking the package contents Check whether the box contains all the items specified in the section Delivery items on page 75 Check the individual parts for transport damage 2 2 Installing the power module optional Note Hirschmann IT provides ready to run power modules You can choose to install the power module while the device is running 2 2 1 ...

Страница 41: ...ay become hot Avoid touching the device while it is operating Failure to follow this instruction can result in injury 2 3 Installing and grounding the device Perform the following work steps Installing the device in the switch cabinet Installing the device on a vertical flat surface Grounding the device 2 3 1 Installing the device in a switch cabinet CAUTION OVERHEAT When installing equipment make...

Страница 42: ...d in a 19 switch cabinet At the time of delivery 2 preinstalled fixed mounting brackets come with the device on the side Make sure the device is well ventilated If necessary install a fan to help prevent overheating Measure the depth of the 19 cabinet for easy connection Perform the following work steps Install the sliding or mounting rails in a 19 switch cabinet as specified by the manufacturer W...

Страница 43: ...Installation MTS2600 2700 2800 Release 01 12 2021 43 Figure 24 Installing the device in a switch cabinet ...

Страница 44: ...njury or device damage 2 3 2 Installing the device on a vertical flat surface Perform the following work steps Attach 2 mounting brackets to the rear of the device Install the 2 screws to attach the mounting brackets to the wall See Figure 25 Tighten the 2 screws with the tightening specified in chapter General technical data on page 55 Figure 25 Installing the device on a vertical flat surface WA...

Страница 45: ...ing the device The device has the connection of the protective grounding wire The device is grounded by the grounding screw and the power socket Perform the following work steps Install the grounding screw at the rear of the device to the protective conductor see Figure 26 Figure 26 Grounding the device Tighten the grounding screw with the tightening torque specified in chapter General technical d...

Страница 46: ...rs See Accessories on the page 75 Perform the following work steps Take the SFP transceiver out of the transport packaging Remove the protection cap from the SFP transceiver See Figure 27 Figure 27 Removing the Protection Cap Push the SFP transceiver with the lock closed into the slot until it latches in See Figure 28 Figure 28 Installing the transceiver ...

Страница 47: ...ical data cables for the data transmission between the buildings When using copper cables provide a sufficient separation between the power supply cables and the data cables Ideally install the cables in separate cable channels Verify that power supply cables and data cables do not run parallel over longer distances To reduce inductive coupling verify that the power supply cables and data cables c...

Страница 48: ...48 Installation MTS2600 2700 2800 Release 01 12 2021 2 7 Filling out the inscription Label The information field for the MAC address helps you identify your device ...

Страница 49: ...Note Configuring 2 or more devices with the same IP address may lead to the network s failure to function as expected Install and maintain a program to assign a unique IP address to each device in the network Enter the IP parameters when you install the device for the first time ...

Страница 50: ...of the device for example the distance from other devices or other objects and the output of neighboring devices The temperature displayed in the CLI and the GUI is the internal temperature of the device It is higher than the ambient air temperature The maximum internal temperature of the device named in the technical data is a guideline that indicates to you that the maximum ambient air temperatu...

Страница 51: ...ernal fuse triggers only when the equipment detects an error In case of any damage or failure to the equipment switch off the power and return the equipment to the plant for inspection Hirschmann is continually working on improving and developing their software Check regularly whether there is an updated version of the software that provides you with additional benefits You find information and so...

Страница 52: ...a module Perform the following work steps Remove the screws from the front panel of the media module Pull the locking lever outward to unlock the media module Pull the media module out of the slot See Figure 30 Figure 30 Removing the media module Put a cover plate at the media module slot on the device Install 2 screws to attach the cover plate to the media module slot Tighten the 2 screws with th...

Страница 53: ...e SFP transceiver Perform the following work steps Release the lock and pull the SFP transceiver out of the device slot See Figure 31 Figure 31 Releasing the lock Use a protective cover to blank the SFP transceiver See Figure 32 Figure 32 Installing the Protective Cover ...

Страница 54: ...cable Disconnect the grounding 6 4 1 Removing the device from a vertical flat surface Perform the following work steps Remove the 2 screws that attach the mounting bracket to the vertical flat surface Remove the 2 mounting brackets from the rear of the device 6 4 2 Removing the device from the switch cabinet Perform the following work steps Remove the screws that attach the mounting bracket to the...

Страница 55: ...X E 5 kg 11 02 lb Power supply Rated voltage range 100 V AC 240 V AC 50 Hz 60 Hz Maximum conductor diameter AWG12 2 5 mm Device grounding Tighten torque Protective grounding 0 4 Nm 0 7 Nm 3 5 lb in 6 1 lb in Climatic conditions during operation Ambient air temperature 5 55 2000 m Note The altitude is 2000 m 4000 m 6561 6 ft 13123 3 ft and the maximum working temperature decreases by 1 33 8 every 2...

Страница 56: ...orque 0 4 Nm 0 6 Nm 3 5 lb in 5 2 lb in Installation of the cover plate Tightening torque 0 4 Nm 0 6 Nm 3 5 lb in 5 2 lb in Power module Rated voltage range 100 V AC 240 V AC 50 Hz 60 Hz Media module Size See Dimension drawings on page 57 Weight MTM2700 2X 0 16 kg 0 35 lb Install media module Tightening torque 0 2 Nm 0 3 Nm 2 0 lb in 3 1 lb in Mount cover plate Tightening torque 0 2 Nm 0 3 Nm 2 0 ...

Страница 57: ...Installation MTS2600 2700 2800 Release 01 12 2021 57 7 2 Dimension drawing Basic device MTS2624 4X B ...

Страница 58: ...58 Installation MTS2600 2700 2800 Release 01 12 2021 MTS2724 4X FP S ...

Страница 59: ...Installation MTS2600 2700 2800 Release 01 12 2021 59 MTS2724 6X MP E ...

Страница 60: ...60 Installation MTS2600 2700 2800 Release 01 12 2021 MTS2748 6X MP E ...

Страница 61: ...Installation MTS2600 2700 2800 Release 01 12 2021 61 MTS2832TF 4X E ...

Страница 62: ...62 Installation MTS2600 2700 2800 Release 01 12 2021 MTS2824F 4X S ...

Страница 63: ...Installation MTS2600 2700 2800 Release 01 12 2021 63 MTS2824 4X S ...

Страница 64: ...64 Installation MTS2600 2700 2800 Release 01 12 2021 MTS2848 6X S ...

Страница 65: ...Installation MTS2600 2700 2800 Release 01 12 2021 65 MTS2824 6X E ...

Страница 66: ...66 Installation MTS2600 2700 2800 Release 01 12 2021 MTS2848 6X E ...

Страница 67: ...Installation MTS2600 2700 2800 Release 01 12 2021 67 Power module MTM2700 PSU120 ...

Страница 68: ...68 Installation MTS2600 2700 2800 Release 01 12 2021 MTM2700 PSU500 ...

Страница 69: ...Installation MTS2600 2700 2800 Release 01 12 2021 69 Media module MTM2700 2X ...

Страница 70: ...Line Class A DNV GL Guide AC DC Power Line FCC 47 CFR Part 15 AC DC Power Line Class A EN 61000 6 4 AC DC Power Line Fulfilled EN 55032 Signal Line Class A EN 61000 6 4 Signal Line Fulfilled Harmonic current EN 61000 3 2 Class A Voltage flicker EN 61000 3 3 EMC interference immunity Standard application Electrostatic discharge EN 61000 4 2 IEEE C37 90 3 Contact discharge 4 kV EN 61000 4 2 IEEE C37...

Страница 71: ... 3 V m IEEE 1613 80 MHz 1000 MHz Fast transient burst EN 61000 4 4 IEEE C37 90 1 AC DC Power Line 2 kV EN 61000 4 4 IEEE C37 90 1 Data cable 1 kV EN 61000 4 5 Cable ground 2 kV Voltage surge power cable IEEE 1613 Cable ground EN 61000 4 5 Cable cable 1 kV Voltage surge data cable EN 61000 4 5 Cable ground 1 kV Conducted immunity EN 61000 4 6 150 kHz 80 MHz 10 V ...

Страница 72: ... cable EN 61000 4 12 IEEE C37 90 1 Cable ground EN 61000 4 12 Cable cable Pulsed magnet field EN 61000 4 9 Power frequency magnetic field EN 61000 4 8 30 A m Voltage dips short interruptions EN 61000 4 11 AC DC Power Line 20 ms U 100 200 ms U 60 500 ms U 30 5 s U 100 Immunity Standard application IEC 60068 2 6 Test Fc Vibration 5 Hz 8 4 Hz amplitude 0 14 in 3 5 mm 8 4 Hz 150 Hz 1g IEC 60068 2 27 T...

Страница 73: ... LC SM TX1310 nm RX1550 nm 10 km 14 dB link budget at 1310 1550 nm 0 18 dB km 18 ps nmxkm BIDI TypeB LX LC SM TX1550 nm RX1310 nm 10 km 14 dB link budget at 1550 1310 nm 0 32 dB km LX LC 1550 SM 1550 nm 40 km 19 dB link budget at 1550 nm 0 18 dB km Table 3 Fiber port 1G SFP module a MM multi module SM simple module LH single mode long haul b When optical fiber data is observed it includes 3dB syst...

Страница 74: ...129 5 Btu IT h MTS2848 6X E 55 W 192 5 Btu IT h Name Maximum power consumption Power output 1G SFP MTS SFP 1G BIDI TypeA LX LC 1 W 3 5 Btu IT h MTS SFP 1G BIDI TypeB LX LC 1 W 3 5 Btu IT h MTS SFP 1G LH LC 1 W 3 5 Btu IT h MTS SFP 1G LH LC 1 W 3 5 Btu IT h MTS SFP 1G LX LC 1 W 3 5 Btu IT h MTS SFP 1G LX LC 1550 1 W 3 5 Btu IT h MTS SFP 1G LX LC 1 W 3 5 Btu IT h MTS SFP 1G SX LC 1 W 3 5 Btu IT h MT...

Страница 75: ...43 MTS2824 4X S 942 999 844 MTS2824F 4X S 942 999 845 MTS2832TF 4X E 942 999 846 Accessories Note the fact that the products used as accessories may have different characteristics from the device itself limits the influence sphere of the whole system For example if you apply IP20 accessory to IP65 equipment the entire system will be reduced to IP20 1G SFP module Order number MTS SFP 1G TX RJ45 942...

Страница 76: ... 01 12 2021 10G SFP module Order number MTS SFP 10G SR LC 942 999 851 MTS SFP 10G LR LC 942 999 852 MTS SFP 10G ER LC 942 999 853 MTS SFP 10G TX RJ45 942 999 867 You may access more information about certificates here https catalog belden com ...

Страница 77: ...omagnetic compatibility EMC Part 3 3 Threshold Limitation of voltage changes voltage fluctuations and flicker in public low voltage supply systems for equipment with rated current 16 A per phase and not subject to conditional connection EN 61000 6 2 Electromagnetic compatibility EMC Part 6 2 Generic standards Immunity for industrial environments EN 61000 6 4 Electromagnetic compatibility EMC Part ...

Страница 78: ... in your area or Hirschmann IT directly You find the addresses of our partners on the Internet at https catalog belden com A list of local telephone numbers and email addresses for technical support directly from Hirschmann IT is available at https catalog belden com This site also includes a free of charge knowledge base and a software download section ...

Страница 79: ...Installation MTS2600 2700 2800 Release 01 12 2021 79 ...

Отзывы: