Bel Canto E.ONE Series DAC 3.5vb Скачать руководство пользователя страница 3

This symbol is intended to alert the user to 
the presence of uninsulated dangerous 
voltages within the enclosure of sufficient 
magnitude to cause electric shock.

 

 

 

Explanation of symbols used in this manual or on the 
rear/underside of the apparatus:   
 

 

 

 

 

 
 

 

 
 
 
 

CAUTION 
• 

To reduce the risks of electric shock, do not remove 
the cover. 

• 

No user serviceable parts inside. 

• 

Refer servicing to qualified service personnel. 

• 

Replace the mains fuse in the plug with one of the 
same type and rating. 

• 

Disconnect supply cord before changing fuse. 

 
 
WARNING 
To reduce the risks of fire or electric shock, do not open 
chassis or expose this apparatus to water or moisture.  
 

 

 

 

 

Read, keep and follow these instructions. 

 

 

Heed all warnings. 

 

 

Do not use the apparatus near water, ie near a 
bathtub, kitchen sink, laundry tub, in a wet 
basement, near a swimming pool etc. 

 

 

Clean only with dry cloth. 

 

 

Do not block any ventilation openings. Install in 
accordance with the Manufacturer’s instructions. 
Site the apparatus so that its location or position 
does not interfere with its proper ventilation. For 
example, the apparatus should not be situated on 
a bed, sofa, rug, or similar surface that may block 
the ventilation openings, or placed in a built in 
installation such as a bookcase or cabinet that 
may impede the flow of air through the ventilation 
openings. 

 

 

Do not install near any heat sources such as 
radiators, heat registers, stoves, or other 
apparatus that produce heat. 

 

 

Do not defeat the safety purpose of the polarized 
or grounding type plug. A polarized plug has two 
blades with one wider than the other. A 
grounding type plug has two blades and a third 
grounding prong. The wide blade or the third 
prong is provided for your safety. If the provided 
plug does not fit into your outlet; consult an 
electrician for replacement of the obsolete outlet. 

 

 
 
 

 

 

Protect the power cord from being walked on or 
pinched particularly at plugs, convenience 
receptacles, and at the point where they exit from 
the apparatus. 

 

 

Unplug this apparatus during lightning storms or 
when unused for long periods of time. 

 

 

Refer all servicing to qualified service personnel. 
Servicing is required when the apparatus has 
been damaged in any way, such as power-supply 
cord or plug has been damaged, liquid has been 
spilled or objects have fallen into the apparatus, 
the apparatus has been exposed to rain or 
moisture, does not operate normally, or has been 
dropped. 

 

 

Mains plug: Use the mains plug to disconnect the 
apparatus from the mains supply. The mains plug 
must be accessible at all times. Use the mains 
switch (if applicable) when the apparatus is not in 
use. 

 

 

Objects and liquid entry: Do not let objects or 
liquids fall into the apparatus. Do not expose the 
apparatus to dripping or splashing. Do not place 
a vessel containing liquid on top of the apparatus. 

 

 

No naked flame sources, such as lighted 
candles, should be placed on the apparatus. 

 

 

The apparatus has been designed for use in 
moderate and tropical climates 

 

 

This symbol is intended to alert the user to 
the presence of important operation, 
maintenance and servicing information in 
the instruction and service manuals. 

 

Содержание E.ONE Series DAC 3.5vb

Страница 1: ......

Страница 2: ...stem or transmitted in any form or by any means electronic mechanical photocopying recording or otherwise without the prior written permission of Bel Canto Design The content of this manual is provided for information use only is subject to change without notice and should not be construed as a commitment by Bel Canto Design Limited Bel Canto Design Limited assumes no responsibility or liability f...

Страница 3: ...ty purpose of the polarized or grounding type plug A polarized plug has two blades with one wider than the other A grounding type plug has two blades and a third grounding prong The wide blade or the third prong is provided for your safety If the provided plug does not fit into your outlet consult an electrician for replacement of the obsolete outlet Protect the power cord from being walked on or ...

Страница 4: ...dards EN55013 2001 Conducted emissions EN55013 2001 Absorbed emissions EN55020 2002 Immunity The conformity of the designated product with the provisions of Directive number 2005 32 EC ecodesign requirements is proved by full compliance with the off mode setting power of 0 0 Watts Note This equipment has been tested and found to comply with the limits for a Class B digital device pursuant to Part ...

Страница 5: ...MA form in the support section of our website If you have any questions please feel free to contact us online at info belcantodesign com DAC3 5VB packaging contains the following 1 one DAC3 5VB 1 one DAC3 5VB User s Guide 1 one VB Interconnect Power Cable 1 one Remote Control Carefully unpack each piece and check for shipping damage If there is any damage or if anything is missing please contact y...

Страница 6: ...sources All digital input sources experience 2 jitter rejection stages one analog PLL stage at the SPDIF input and a second 2Hz digital PLL stage that rolls off incoming jitter by more than 10X at 10Hz frequencies and greater than 10 000X by 100 Hz Any incoming jitter at frequencies above 10Hz is reduced to levels that have no effect on measured or sonic performance The combination of the VBS1 int...

Страница 7: ...right of the display is highlighted The volume down function counter clockwise rotation is very rapid and allows quick changes in the volume level Volume up clockwise rotation functions rapidly up to a displayed volume level of 65 0 Volume is adjustable from 0 0 to 100 0 by increments of 0 5 Fixed Output Operating Mode Pressing the rear panel Fixed Variable Output switch to the in position will se...

Страница 8: ...Theatre Bypass HTB In this mode the analog input simply passes signal through with a fixed output level Note that this disables the volume control and requires that the volume control on the Home Theater processor be used Use this feature only with a volume controlled line level source Using this with the fixed output of a CD player for example could result in damage to the amplifier or loudspeake...

Страница 9: ... and Un muted modes Soft Mute is indicated by the word SOFT overwritten on the volume level display Hard mute over writes the level display with MUTE The Mute function will Punch Through to any Bel Canto unit set in Variable Output mode Number Buttons Use for direct input selection 1 AES 2 SPDIF1 3 SPDIF2 4 TOSLINK 5 High Speed ST Fiber 6 Analog Input Bal L Bal R Shift the balance up to 6 0 dB tow...

Страница 10: ... 24 192 data rate SPDIF1 and SPDIF2 accept BNC or RCA connections from any 75 ohm SPDIF source and operate to at least 24 192 data rate AES EBU Input accepts any AES EBU standard 110 ohm digital source and operates up to 24 192 data rate XLR 5 5Vrms or 7 RCA 2 75Vrms outputs are used for directly driving a power amplifier in variable output mode or a preamplifier input when in fixed output mode RC...

Страница 11: ...ment notches on both units power receptacles and the power interconnect cable When inserting the power interconnect cable align the notch on the cable end and the alignment teeth on the outer sleeve to the 12 o clock position This will allow the interconnect cable to fully seat and ensure that the plug mates correctly with the power receptacle Once the power interconnect cable is fully seated in t...

Страница 12: ...e USB out of your computer to connect into the DAC3 5VB via either the USB Link 24 96 or the USB Light Link 24 96 For more details on optimizing computer audio sources please refer to our on line guide at www belcantodesign com What to do if there is hum or ground noise The design of the DAC3 5VB greatly reduces the chance for ground loop induced hum and noise We recommend using the balanced outpu...

Страница 13: ...Response 20 Hz 20 KHz 0 5dB THD N 0 0015 5 5Vrms balanced out 1KHz Output Noise 3uVrms A weighted 20Hz 20KHz Dynamic Range 126dB A weighted 20Hz 20KHz Analog 24 192 ADC Section Maximum Input 2 5 Vrms RCA Input Impedance 12K ohms RCA Frequency Response 20 Hz 20KHz 0 5dB THD N 0 003 2 5Vrms in 1KHz Dynamic Range 110dB A weighted 20Hz 20KHz General Power Usage On 9W Power Usage Off 0 0W Power Require...

Страница 14: ......

Страница 15: ......

Отзывы: