background image

 

 
 

Rear Panel Connections 

 
 

 

Never Connect Either the Positive or Negative Speaker Output to Any Ground Contact! 
Use Class 2 Wiring for all Loudspeaker Connections! 

 
Connecting any Speaker Output on the REF500

S

 to Ground will cause the amplifier to go into protection and 

could damage the amplifier and void the warranty. 
 

 

Power Switch: Power is on when the switch is 
toggled to the I position and off in the O position. 

 

 

Input Connections and RCA/XLR switch: When 
using RCA cables for the input ensure that the 
RCA/XLR switch is pressed in to the RCA 
position. When using XLR cables insure that the 
switch is out in the XLR position. 

Do not 

connect both XLR and RCA cables to the 
inputs!

 

 

 
 
 
 
 
 

 

Output Connections: Attach your loudspeaker to 
the output connectors. Be sure that the polarity 
of each speaker is correct and the same for both 
channels so that no phase inversion can occur. 

 

 

IEC power cord jack: Connect a heavy gauge 
power cord from this jack to the wall power 
supply. Note the power setting indicated on the 
back of the amplifier before connecting the 
power.  

 
Double-check all connections to and from the 
amplifier.  Power on the preamplifier in your system, 
activate its Mute setting and then power on the  
REF500

S

Front Panel Indicator Lamp 
What to do if there is hum or ground noise: 

 
 
 
 
 

 

 

Содержание e.One REF500s

Страница 1: ......

Страница 2: ...m or by any means electronic mechanical photocopying recording or otherwise without the prior written permission of Bel Canto Design The content of this manual is provided for information use only is subject to change without notice and should not be construed as a commitment by Bel Canto Design Limited Bel Canto Design Limited assumes no responsibility or liability for any errors or inaccuracies ...

Страница 3: ... stoves or other apparatus that produce heat Do not defeat the safety purpose of the polarized or grounding type plug A polarized plug has two blades with one wider than the other A grounding type plug has two blades and a third grounding prong The wide blade or the third prong is provided for your safety If the provided plug does not fit into your outlet consult an electrician for replacement of ...

Страница 4: ...of the FCC Rules These limits are designed to provide reasonable protection against harmful interference in a residential installation This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instructions may cause harmful interference to radio communications However there is no guarantee that interference will not occur in a particu...

Страница 5: ...thorization number issued after completing the RMA form in the support section of our website If you have any questions please feel free to contact us online at info belcantodesign com REF500S packaging contains the following 1 one REF500S Amplifier 1 one REF500S User s Guide 1 one Power cord 6 6 2 meters long Carefully unpack each piece and check for shipping damage If there is any damage or if a...

Страница 6: ...stom input stage is added for increased linearity common mode rejection and improved input stage drive to the amplifier This circuit results in lower noise in real world operation lower distortion and better dynamic performance for the amplifier The input stage uses the latest advanced amplifiers and passive components including Caddock resistors Solid Electrolytic ultra low ESR decoupling capacit...

Страница 7: ...e RCA position When using XLR cables insure that the switch is out in the XLR position Do not connect both XLR and RCA cables to the inputs Output Connections Attach your loudspeaker to the output connectors Be sure that the polarity of each speaker is correct and the same for both channels so that no phase inversion can occur IEC power cord jack Connect a heavy gauge power cord from this jack to ...

Страница 8: ...to disconnect the power ground from the REF500S as this may lead to dangerous operation and void the warranty The small blue LED lamp indicates that power is connected to the REF500S and that the power switch is in the ON position If the amplifier detects a fault or short circuit in the output connections it will go into a protection mode and stop playing If this occurs toggle the power switch to ...

Страница 9: ...le ended or balanced input Damping factor 1000 Output Impedance at 100Hz 8 milliohms Dynamic Range 121dB Input Voltage for Max Output 2Vrms Input connections Single ended RCA or balanced XLR RCA input impedance 100Kohms Balanced input impedance 200Kohms Output connections 2 sets WBT nextgen 5 way binding posts Power On usage 19W Power Off usage 0 0W Internally Set Operating Voltages 100 120VAC or ...

Страница 10: ... 3 3 1995 A1 2001 A2 2005 EN 60065 2002 A12 2011 Manufacturer Bel Canto Design Ltd 221 1 st Street North Minneapolis MN 55401 USA The equipment identified here conforms to the Directive s and Standard s specified above Type of Equipment Audio Amplifier Models REF500S Date January 2012 Bel Canto Design Ltd 221 1 st Street North Minneapolis MN 55401 USA Tel 612 317 4550 Fax 612 359 9358 ...

Страница 11: ...version 4 0 ...

Отзывы: