Beko Elektronik A.S Service Manual Plasma Display Module-Samsung V3
42 / 44
9) Check the Low-discharge, Over-discharge and panel condition by adjusting the Pattern Generator Level.
7. Operation Check
7-1 Adjustment Specification, Checking Position etc.
V3.1 TCP Ramp Waveform Inclination Adjustment ( Y-Board )
* Dip Switch Mode
< Internal > <External>
Adjust VR5002 to set the time of Vset
in 10
㎲
Adjust VR5002 to set the time of
Vset in
10
㎲
Adjust VR5001 to set the 3SF Falling
time in 30
㎲
Adjust VR5004 to set the voltage of
Vsch in 40V