Transmit operation 

 

 

ATTENTION  !

  This  device  is  for  split  line  operation  only.  There  is  no 

output  relay  inside.  Separate  cables  for  TX  and  RX  must  be  used.  An 
external output relay can be used with the internal sequencer. SEE Chapter 
Remote control for more details.
 
 
The  RX/TX-switching  is  activated  by  applying  zero  volts  or  ground  to  the 
“PTT”  or  pin  6  of  the  “CONTROL”-jack  on  the  rear  panel  and  will  be 
indicated  by  the  illuminated  green  “PTT”-LED.  On  most  transceivers  this 
voltage is supplied separately by an accessory output on their rear panel.  
The  internal  input  coaxial  relays  is  controlled  with  a  different  time  delay  to 
allow for it’s specific switching time and achieve zero power switching.  
The internal control circuit also provides a sequence controlled switching of an 
external antenna relay instead of the missing output relay inside. On pin 2 of the 
“CONTROL” jack a voltage of 14 VDC is provided. It is short circuit protected 
by use of a 1,25A PTC-fuse. 
 
The PTT line is also used to generate the bias voltage to run the MOSFETs in 
class AB. Without RF input the total idle current is 4 A, equivalent to dissipating 
200  watts.  An  internal  generated  and  delayed  PTT-  function  is  available  at  the 
inner  contact  of  the  rear  sided  “AUX“-  jack  to  reliably  control  a  connected 
transceiver. Any potential at the inner conductor is switched to ground. 
 
In essence, your amplifier provides a built-in multi-level sequencer which 
provides an alternate means to key your radio last.   
When the amplifier PTT is activated usually via a foot switch, the preamp 
voltage is dropped first, internal relays are switched, the RF amplifier section is 
turned on and finally via the AUX jack a ground on transmit is available to key 
your radio. 
 
When using SSB you should not exceed 2,5 watts of input power to achieve best 
spectral  purity  with  low  inter-modulation  distortion.  A  red  LED  indicator 
integrated in the front panel power meter indicates the 1 dB compression point 
limit  at  800  watts.  Exceeding  this  limit  will  cause  harmonic  distortions  to  be 
transmitted.  An  integrated  peak-hold  function  provides  a  more  effective 
indication of the output power. 

 

 

 
 
 
 

Содержание HLV-800-3

Страница 1: ...1 HLV 800 3 Instruction Operations Manual Content ...

Страница 2: ...ructions 5 4 Electrical connections 6 5 Warranty 7 6 Front panel operation 8 7 Protection circuits 9 8 Receive Transmit switching 10 9 Remote control 11 10 Cooling technique 12 11 Block diagram 13 12 Adjustment of protection thresholds 14 13 Control circuit schematic 15 14 tbt ...

Страница 3: ...8 EC and 99 5 EC EN 301 783 1 V1 1 1 2000 09 EN 301 783 2 V1 1 1 2000 09 EN 301 489 1 V1 6 1 2005 09 EN 301 489 15 V1 2 1 2002 08 EN 60950 1 2006 All necessary test procedures have been successfully passed Manufacturer and authorized representative BEKO ELEKTRONIK Am Längenmoosgraben 1a D 85221 Dachau GERMANY This declaration has been accomplished under unique reponsability of the manufacturer BEK...

Страница 4: ... an external output relay The internal modulated power limit is kept to 950 watts It s design is based on NXP s rf transistor BLF6G13L 250P Each of the four amplifier blocks is protected by a separate circulator before final 4 1 combining This insures high ruggedness and independence on any load mismatch as well as high linearity and spectral purity It is essential that the driving source has a na...

Страница 5: ...dity of less than 85 In order to avoid malfunction caused by condensation you will have to wait at least one hour before start of operation and until the condensation has been removed 6 To prevent electrical shock do not remove the cover before disconnecting the mains plug 7 The bottom openings are used as a cooling air inlet and the rear side outlet to exhaust the inside generated heat They must ...

Страница 6: ...ion of the specifications and shifting of the threshold voltages of the protection circuits Operation with no load connected is not allowed 5 The RF connectors are 7 16 DIN and N type Only high quality connectors with PTFE insulation must be used Neglecting will cause overload and damage of the connectors and shifting of the thresholds of the protection circuits Special care must be taken when con...

Страница 7: ...ll claims on warranty The device is protected by an invisible seal against opening Damage of the seal will invalidate the warranty Warranty is also excluded if damages are caused by 1 Overdrive with power levels 75W or with power peaks caused by insufficient ALC control of the driving source 2 Feedback oscillations due to direct radiation caused by too small distance between antenna and amplifier ...

Страница 8: ...ning off the preamplifier and turns the preamplifier on after switching off the RF power unit The supply voltage for the use of an external preamplifier is fed to pin 4 of the CONTROL jack at the rear panel It is short circuit protected by use of a ptc fuse and supplies 15 volts 750 mA Preamps that can only accept voltage feed via the coaxial cable can t be used with this amplifier STANDBY If the ...

Страница 9: ...sconnected from the mains when disabling the audible alarm 7 Protection circuits The HLV 800 s internal control circuit supervises the output load condition an overdrive of the input stage and the thermal status of heat sink and power supply unit If the amount of reflected power exceeds 300 watts the protection circuit shuts off the RF unit immediately and switches the drive power to bypass mode T...

Страница 10: ...The PTT line is also used to generate the bias voltage to run the MOSFETs in class AB Without RF input the total idle current is 4 A equivalent to dissipating 200 watts An internal generated and delayed PTT function is available at the inner contact of the rear sided AUX jack to reliably control a connected transceiver Any potential at the inner conductor is switched to ground In essence your ampl...

Страница 11: ... easily be activated by an external switch wired to ground Output power can be monitored 100 of output power is equal to 10V DC on Pin 5 Output relay ext PREAMP 15V DC 5K Shield 100 power level 10V DC POWER ext 6 7 ext switch box Alarm out 4 8V PTT RESET PREAMP 1 mA 5 4 3 2 1 Remote control HLV 800 ...

Страница 12: ...o achieve best airflow for cooling the air in and outlets must not be covered Do not operate the amplifier in close proximity to heaters and radiators If thermal shut down occurs you should wait until the device temperature decreases sufficiently before switching on the amplifier again Please read also our Safety instructions and Electrical connections ATTENTION This device is not designed for 100...

Страница 13: ...13 11 Block diagram ...

Страница 14: ... are too sensitive and need some slight correction In the picture below all trimpots incl their functions are shown Turning the slots clockwise is equal to or upward direction and verse vice Readjustment should be done very carefully otherwise the effect of protection is cancelled ...

Отзывы: