13/EN
Room ventilation
All rooms require an openable window,
or equivalent, and some rooms will
require a permanent vent as well. The air
for combustion is taken from the room
air and the exhaust gases are emitted
directly into the room. Good ventilation
is essential for safe operation of your
appliance.
Rooms with doors and/or windows
which open directly to the outer
environment
The doors and/or windows that open
directly to the outer environment must
have a total ventilation opening of the
dimensions specified in the table below
which is based on the total gas power of
the appliance (total gas power
consumption of the appliance is shown
in the technical specification table of this
user manual). If the doors and/or
windows do not have a total ventilation
opening corresponding to the total gas
consumption of the appliance as
specified in the table below, then there
must definitely be an additional fixed
ventilation opening in the room to ensure
that the total minimum ventilation
requirements for the total gas
consumption of the appliance is
achieved. The fixed ventilation opening
can include openings for existing
airbricks, extraction hood ducting
opening dimension etc.
Total gas
consumption
(kW)
min. Ventilation
opening (cm
2
)
0-2
100
2-3
120
3-4
175
4-6
300
6-8
400
8-10
500
10-11.5
600
Total gas
consumption
(kW)
min. Ventilation
opening (cm
2
)
11.5-13
700
13-15.5
800
15.5-17
900
17-19
1000
19-24
1250
Rooms that do not have openable
doors and/or windows that open
directly to the outer environment
If the room where the appliance is
installed does not have a door and/or a
window that opens directly to the outer
environment, other products shall be
sought that definitely provide a fixed
nonadjustable and non-closable
ventilation opening which meets the total
minimum ventilation opening
requirements for the total gas
consumption of the appliance as
indicated in the above table.Also the
appropriate building regulations advise
should be followed.
Where a room or internal space contains
more than one gas appliance, additional
ventilation area shall be provided on top
of the requirement given in the table
above. Size of additional ventilation area
shall be appropriate to regulations of
other gas appliances.
There should also be a minimum
clearance of 10mm on the bottom edge
of the door that opens to the inner
environment in the room where the
appliance is installed.You must ensure
that items such as carpets and other
floorcoverings etc., do not affect the
clearance when the door is closed.
The cooker may be located in a kitchen,
kitchen/diner or a bed-sitting room, but
not in a room containing a bath or a
shower. The cooker must not be