Beko CTB 6250 XA Скачать руководство пользователя страница 8

8 / 11  EN

Hood / User Manual

Closing Element

• The space between the edge of the hood and 

the rear wall can be closed by applying the 

element 20 provided, using the screws supplied 

for this purpose.

3.2 Connection
3.2.1 Ducted Version Air Exhaust 
System

When installing the ducted version, connect the 

hood to the chimney using either a flexible or rigid 

pipe ø 150 or 120 mm, the choice of which is left 

to the installer.

• To install a ø 120 mm air exhaust connection, 

insert the reducer flange 9 on the hood body 

outlet.

• Fix the pipe in position using sufficient pipe 

clamps (not supplied).

• Remove possible charcoal filters.

3.2.2 Recirculation Version Air Outlet

• Cut a hole ø 125 mm in any shelf that may be 

positioned over the hood.

• Insert the reducer flange 9 on the hood body 

outlet.

• Connect the flange to the outlet on the shelf 

over the hood by using a flexible or rigid pipe 

ø120 mm.

• Fix the pipe in position using sufficient pipe 

clamps (not supplied).

• Fix the air outlet grid 8 on the recirculation air 

outlet by using the 2 screws 12e (2,9 x 9,5) 

provided.

• Ensure that the activated charcoal filters have 

been inserted.

3.2.3 Electrical Connection

• Connect the hood to the mains through a two-

pole switch having a contact gap of at least 

3mm.

• When opening the sliding carriage for the first 

time after installing the hood, pull it out briskly 

until it clicks.

Installation

Содержание CTB 6250 XA

Страница 1: ...Hood User Manual CTB 6250 XA CTB 9250 XA ...

Страница 2: ... is also applicable for several other models Differences between models will be identified in the manual Explanation of symbols Throughout this user manual the following symbols are used C Important information or useful hints about usage A Warning for hazardous situations with regard to life and property B Warning for electric shock Packaging materials of the product are manufactured from recycla...

Страница 3: ...Support surface and Fitting the Hood 7 3 2 Connection 8 3 2 1 Ducted Version Air Exhaust System 8 3 2 2 Recirculation Version Air Outlet 8 3 2 3 Electrical Connection 8 4 Use 9 4 1 Control panel 9 5 Maintenance 10 5 1 Grease Filters 10 5 1 1 Cleaning Metal Self Supporting Grease Filters 10 5 2 Charcoal filter Recycling version 10 5 2 1 Replacing Charcoal Filters 10 5 3 Lighting 11 5 3 1 Light Repl...

Страница 4: ... ventilation of the room when the range hood is used at the same time as appliances burning gas or other fuels Not applicable to appliances that only discharge the air back into the room There is a risk of fire if cleaning is not carried out in accordance with the instructions Do not flambé under the range hood Caution Accessible parts may become hot when used with a cooking appliance The applianc...

Страница 5: ... gas hob specify a greater distance this must be taken into ac count The distance of 65cm can be reduced for non combustible parts of range hoods and parts operating at safety extra low voltage pro vided these parts do not give access to live parts Distance may be reduced to 60cm to align with the AGA code Regulations concerning the discharge of air have to be fulfilled Warning Failure to install ...

Страница 6: ...cs CTB 6250 XA CTB 9250 XA Width 598 mm 898 mm Depth 175 mm Height 280 mm Supply voltage 220 240 V 50 60 Hz Control 3 positions Suction power 420 m3 h Motor power 140 W Lamp power 2X28 W Total power 196 W Air outlet pipe diameter 150 mm Net weight 7 6 kg 9 3 kg Gross weight 8 5 kg 10 5 kg 2 3 Technical Specifications Markings on the product or the values stated in other documents supplied with the...

Страница 7: ...n the support surface using the drilling template provided Fix using the 4 screws 12a 4 2 x 44 4 provi ded 3 Installation Snap On Fitting The hood can be installed either directly on the bottom surface of the wall units using snap on side supports Cut a fitted opening in the bottom surface of the wall unit as shown Insert the hood until the side supports snap into place Lock in position by tighten...

Страница 8: ...Remove possible charcoal filters 3 2 2 Recirculation Version Air Outlet Cut a hole ø 125 mm in any shelf that may be positioned over the hood Insert the reducer flange 9 on the hood body outlet Connect the flange to the outlet on the shelf over the hood by using a flexible or rigid pipe ø120 mm Fix the pipe in position using sufficient pipe clamps not supplied Fix the air outlet grid 8 on the reci...

Страница 9: ...st operating conditions given the optimum treated air flow noise level ratio 3 Maximum speed used for eliminating the highest cooking vapour emission including long periods L Light Switches the lighting system on and off M Motor Switches the extractor motor on and off V Speed Sets the operating speed of the extractor 1 Low speed used for a con tinuous and silent air change in the presence of light...

Страница 10: ...ime but this has no influence to the filter efficiency When refitting the filters make sure that the handle is visible on the outside Close the sliding suction panel 5 2 Charcoal filter Recycling version 5 2 1 Replacing Charcoal Filters A Warning Turn the lights off and wait until the lamps cool down before you change the odour filter These filters are not washable and cannot be regenerated and mu...

Страница 11: ...ser Manual 5 3 Lighting 5 3 1 Light Replacement 28W light Remove the metal grease filters Unscrew the bulbs and replace them with new ones having the same characteristics Replace the metal grease filters 5 Maintenance ...

Страница 12: ...ntee purports to modify or exclude the conditions guarantees and undertakings and other legal rights under the New Zealand Consumer Guarantees Act and other laws except in those circumstances contemplated by section 43 2 of the New Zealand Consumer Guarantees Act Beko Guarantee The Beko Manufacturers Guarantee provides additional protection for your claims which will allow for a quick and simple p...

Страница 13: ...o a valid claim under the terms and conditions of this Guarantee To be eligible for this Guarantee the product must be purchased from an Authorised Reseller in Australia or New Zealand What is not covered under this Guarantee 1 Any service calls in which the problem is found not to be caused or related to any defect in the Product In this instance the cost of the f o o o t d e t i m i l t o n t u ...

Страница 14: ...ions as stated in the user manual f Improper installation g Failure to clean or improper cleaning h Use of incorrect non compliant electrical or gas connections i External sources including but not limited to electrical inter j Any loss caused by civil commotion k Any loss caused from extreme events of nature including but l Use of non genuine authorised parts m Any repair or other work carried ou...

Страница 15: ...Manufacturer s Guarantee is provided by the Beko Aus tralia and New Zealand Authorised Repairer The Guarantee is provided by Beko Australia and New Zealand Pty Ltd ABN 49 152 055 162 of 55 Blanck Street Ormeau QLD Australia 4208 P O Box 354 Ormeau QLD Australia 4208 In Australia if you need assistance Toll Free 1300 282 356 Email Beko care Beko com In New Zealand if you need assistance Toll Free 0...

Страница 16: ......

Отзывы: