WIRING DI
A
G
R
AM - DPDT MODEL (FOR VN MODELS ONLY) (D
C PUMP)
Main Supply
220-240V ~ a.c.
E
Earth
N
L
Neutral
Live
Heating Element A
T2
G
ON / OFF Switch
Flow Switch
N1
Heater Control
Electronic ELCB,
15mA Sensitivity
G
T1
Triac
T2
ON / OFF Switch
Speed Control
Heating Element B
Relay 2
Relay 1
Relay 3
PUMP
Test
Reset
Electronic
ELCB, 15mA
Sensitivity
Double Action Thermostat
Auto-Reset Manual-Reset
Note : (*) For Pump Model
SMPS PCB
ASSY
"ESP" Model
Silent Pump,
48
W
, 24V d.c
WIRING DIAGRAM - DPDT MODEL (FOR VN MODELS ONLY) (NO PUMP / AC PUMP)
Pump Motor
Main Supply
220-240V ~ a.c.
E
Earth
N
L
Neutral
Live
Heating Element A
T2
G
ON / OFF Switch
Flow Switch
N1
Heater Control
Electronic ELCB,
15mA Sensitivity
G
T1
Triac
T2
ON / OFF Switch
Speed Control
EP Model
Heating Element B
Relay 2
Relay 1
Relay 3
PUMP
Test
Reset
Electronic
ELCB, 15mA
Sensitivity
Double Action Thermostat
Auto-Reset Manual-Reset
(*) For PUMP Model
Note : (*) For Pump Model
*Manual Reset (90°C Thermostat)
For Models rated 4.5kW and below, thermostat is manually resetable
Wiring Diagram