EN
9
3
Installation
Installation Instructions
1.
The space in the room where
the appliance is installed must not be
smaller than 10 cubic metres.
2.
If possible avoid placing the
appliance near cookers, radiators or in
direct sunlight as this will cause the
compressor to run for long periods. If
installed next to a source of heat or
refrigerator, maintain the following
minimum side clearances:
From Cookers 2” (50 mm)
From Radiators 2” (300 mm)
From Refrigerators or Freezers 1”
(25 mm)
3.
Make sure that sufficient room
is provided around the appliance to
ensure free air circulation. Allow
a minimum of 60 mm (2.4 inches)
between the top of the appliance and
the ceiling or the underside of a wall
cupboard.
4.
Fit the two plastic wall spacers
supplied onto the condenser at the
back of the appliance by rotating
them 1/4 turn.
5.
The appliance should be
located on a smooth surface. The two
front feet can be adjusted as required.
To ensure that,your appliance is
standing upright adjust the two
front feet by turning clockwise or
anti-clockwise, until the product is in
firm contact with the floor. Correct
adjustment of feet avoids excessive
vibration and noise.
6.
Refer to “Cleaning and Care”
section to prepare your appliance for
use.
7.
A special receptacle is supplied
to store the mains plug during transit.
The receptacle is fixed at the back of
the cabinet, on the right hand side of
the compressor. (See diagram) Gently
remove the plug from the receptacle.
Never pull the mains cord, you may
damage the appliance. In the case
of transportation, ensure you locate
the plug in the receptacle provided to
avoid transit damage. transit provided
to avoid transit damage.