FOUNDATION™ fieldbus

Field mounting

Display

Issue: 9

Содержание FOUNDATION BA684DF-F

Страница 1: ...Issue 9 6 th June 2011 BA684DF F FOUNDATION fieldbus Field mounting Display Issue 9...

Страница 2: ...5 3 Alarm Output 5 3 6 Display 5 3 6 1 Settings 5 3 6 2 Quick Access 5 3 6 3 Access Code 5 3 6 4 Status Text 5 3 6 5 Last Input 5 3 7 Keys 5 3 8 Code 5 3 9 Unit Info 5 3 10 Defaults 5 3 10 1 Display D...

Страница 3: ...arm outputs are locally activated from the fieldbus variable and are configured via the instrument menus and push buttons They can not be controlled via the fieldbus Housed in a robust IP66 glass rein...

Страница 4: ...BA684DF F FOUNDATION fieldbus display may be downloaded from either the Fieldbus Foundation or from the BEKA associates web sites Fig 1 Simplified block diagram of BA684DF F 2 1 Controls The user can...

Страница 5: ...it is recommended that the cable connecting the Fieldbus Display to the external switches is less than 5m long 3 2 Alarm outputs The BA684DF F can be supplied with six alarm outputs that may be linke...

Страница 6: ...hould be connected to the potential equalising conductor The BA684DF F enclosure is supplied with a bonding plate to ensure electrical continuity between the three conduit cable entries 4 2 Installati...

Страница 7: ...7 Fig 5 Dimensions and terminal connections...

Страница 8: ...or button set the first digit of the code which will be flashing Pressing P will transfer control to the next digit which should be adjusted in the same way When all four digits have been set pressin...

Страница 9: ...i e still available but no longer actively supported One variable Two variables Four variables Eight variables One variable horizontal bargraph Two variables horizontal bargraphs One variable vertical...

Страница 10: ...from the zero in front of a decimal place are automatically suppressed 5 3 3 Tags Note Only included in Revision 1 instruments Omitted from Revision 2 instruments because tags can be easily defined i...

Страница 11: ...setpoint to be adjusted and press P the flashing digit to be adjusted may then be selected by again pressing P When all the digits have been adjusted operating the E button enters the value and moves...

Страница 12: ...i e one multiple analogue output function block 1 x MAO The BA684DF F FOUNDATION fieldbus display revision should be chosen so that the fieldbus function blocks selected are supported by the system ho...

Страница 13: ...13...

Страница 14: ...activated Setpoints Bargraph on standard display format is shown dotted Displayed fieldbus variable is outside bargraph limits or data is bad Bargraph limits see section 5 3 5 7 2 Fault finding after...

Страница 15: ...ts Two pipe mounting kits are available for securing the BA684DF F to a horizontal or vertical pipe BA392D Stainless steel bracket secured by two worm drive hose clips for 60 to 80mm outside diameter...

Страница 16: ...l switches 3 1 5 3 7 Fault finding During commissioning 7 1 After commissioning 7 2 Guarantee 7 5 Input scaling 5 3 2 Installation 4 Interface Guides 8 4 Keys 5 3 7 Last Input 5 3 6 5 Location 4 1 Mai...