BEKA BA648CF-P Скачать руководство пользователя страница 2

2

1.  Description

1.1  Documentation

2.Operation

2.1

Error messages

3.  System Design for Hazardous Area

4.  Installation

4.1

Location

4.2

Installation procedure

4.3

EMC

5.  Configuration

5.1

Configuration menus

5.2

Node configuration menu

5.2.1

Enter fieldbus address

5.2.2

Access code

5.2.3

Change from node to listener

5.2.4

Reset to node factory defaults

5.3

Listener configuration menu

5.3.1

Access

5.3.2

Summary of configuration
functions.

5.4

Description of listener menu functions

5.4.1

Scan fieldbus segment

5.4.2

List configured input
parameters.

5.4.3

Enter address & display
parameters.

5.4.4

Enable selected input

5.4.5

Enter source address

5.4.6

Enter destination address

5.4.7

Enter Index

5.4.8

Decimal point position

5.4.9

Configuration of  bargraph

5.4.10 Scale numeric display
5.4.11 Access code for listener

configuration menu.

5.4.12 Change from fieldbus listener to

fieldbus node.

5.4.13 Reset the listener to factory

defaults.

6.  Maintenance

6.1

Fault finding during commissioning

6.2

Fault finding after commissioning

6.3

Servicing

6.4

Routine maintenance

6.5

Guarantee

6.6

Customer comments

7. Accessories

7.1

Scale marking

7.2

Tag number

7.3

Fieldbus Interface Guide

CONTENTS

The BA648CF is CE marked to show compliance with the European EMC Directive 2004/108/EC

Содержание BA648CF-P

Страница 1: ...Issue 2 23 rd June 2011 BA648CF P PROFIBUS PA Panel mounting 8 variable Fieldbus Indicator Issue 2...

Страница 2: ...parameters 5 4 3 Enter address display parameters 5 4 4 Enable selected input 5 4 5 Enter source address 5 4 6 Enter destination address 5 4 7 Enter Index 5 4 8 Decimal point position 5 4 9 Configura...

Страница 3: ...n label There is an alternative version of the fieldbus display order code BA648CF F for use on FOUNDATION fieldbus networks 1 1 Documentation This instruction manual describes installation configurat...

Страница 4: ...panel mounting clips Fig 2 BA648CF P dimensions 4 2 Installation Procedure a Insert the BA648CF P into the instrument panel cut out from the front of the panel b Fix panel mounting clips to opposite...

Страница 5: ...d digit flashing which may be changed by operating the or button When set as required operating the P button will transfer control to the next digit that may be adjusted in the same way When all digit...

Страница 6: ...dresses of the data sources to be displayed by the BA648CF P listener are not known In the SCAn function pressing the P button causes the BA648CF P listener to search the fieldbus segment to which it...

Страница 7: ...7...

Страница 8: ...eters Sub menu which allows known fieldbus device addresses to be entered and all display parameters adjusted for each of the eight fieldbus listener inputs See section 5 4 3 Enb Enable selected input...

Страница 9: ...ource address to the selected input and return the display to the source and destination addresses from which another data source address may be selected When a data source address is allocated to a l...

Страница 10: ...mode irrespective of the numeric value When positioned as required operating the E button will enter the selection and return to the dP prompt in the edit sub menu 5 4 9 Configuration of bargraph dis...

Страница 11: ...evised access code will be activated when the transmitter is returned to the display mode If the access code is lost please contact BEKA associates 5 4 12 Change from fieldbus listener to fieldbus nod...

Страница 12: ...ation after a few seconds the firmware version will be displayed prior to entering the operational mode 6 2 Fault finding after commissioning ENSURE PLANT SAFETY BEFORE STARTING MAINTENANCE If a BA648...

Страница 13: ...a scale for the horizontal bargraph 7 2 Tag number The BA648CF P can be supplied with a thermally printed tag number on the rear panel adjacent to the terminals 7 3 BEKA PROFIBUS PA Display Fieldbus...

Отзывы: