Note 2:
If the BA538C and the 4/20mA current
sink output are powered from separate supplies,
the 4/20mA output current will continue to flow
when the BA538C supply fails or is turned off.
Powering both from a common supply as shown in
Fig 15 eliminates this effect.
Fig 16 4/20mA output programme structure