background image

1

TOUCH MANAGER Modular Matrix

Switcher Series

TOUCH-MANAGER-800

USER MANUAL

Содержание TOUCH MANAGER Series

Страница 1: ...1 TOUCH MANAGER Modular Matrix Switcher Series TOUCH MANAGER 800 USER MANUAL ...

Страница 2: ...products please read the user manual carefully before using them Hope this user manual can bring more convenience and please don t hesitate to get in touch with us or your local dealer if you have any issue during your usage Note This user manual is for 9x9 matrix switch 18x18 and 36x36 also can reference this user manual ...

Страница 3: ...lease turn off the main power switch on rainy days or when not in use for a long time Please do not put anything upon the cables or tread the cables To avoid damaging the device please turn off power supply before plugging cable into the device or pulling cable from device The damage caused by plugging pulling cables without turning off power supply is outside the scope of the warranty The power o...

Страница 4: ... 7 1 1 Switch 7 7 1 2 Scene 7 7 1 3 Set Up 8 7 1 4 View 8 7 2 WEB Control 8 7 2 1 Login 8 7 2 2 Switch 8 7 2 3 Scene 9 7 2 4 Rename 10 7 2 5 centralization Control 10 7 2 6 Set Up 17 7 2 7 Upgrade 18 7 3 APP Control 8 7 4 Control Commands 20 8 Trouble Shooting and Attention 18 9 After Sales 18 9 1 Warranty 19 9 2 limitation and Exception 19 Attachment A TOUCH Modular Matrix input output cards 20 A...

Страница 5: ...working ability Supports 7 24 continuously working and with dual LAN and RS232 backup control it s convenient for users to control via PC iPad APP and the 3rd parties central control by the the RS232 control commands With the dual RS232 and LAN control users also can simply set up and control the surrounding equipment such as the projector electric curtain and TVs This matrix switchers have been w...

Страница 6: ...olor extension color gamut standard Resolution 640x480 1920x1200 60Hz VESA 480i 4K30Hz HDTV 4K60Hz Bandwidth 12 5Gbps Transmission Distance 70 100m Cat6 80Km Single mode 20m Digital cable 25m Analog cable Control Dual RS232 dual LAN WEB GUI front touch panel iPad APP Dimension 482 390 711mm 16U Weight 28KG No cards Power 110 260V 50 60Hz Consumption 180W No cards Working Temperature 10 50 Storage ...

Страница 7: ... operations B Active Indicator Shows the operations of Touch panel control flicking once for every operations C Power Indicator Light up means power on flicking means connection problem D Front Panel 482 711mm E 10 inch touch screen 5 2 Back Panel A Back rack ear B 3 5mm Audio input ...

Страница 8: ...icates flap left side is 1 80 inputs right side is 1 80outputs H 3 5mm Audio output J DVI I interface output support DVI HDMI CVBS Ypbpr VGA input with adapters K Output area maximum can support 80 160 inputs signals can be DVI HDMI CVBS Ypbpr VGA Fiber Optic L N Dual RS232 ports M O Dual LAN ports P ON OFF power switcher Q Redundant power system 100 240V 50 60Hz 6 Connection Diagram 7 Operation 7...

Страница 9: ... Switch input 10 to output 20 30 40 Press number 10 from input buttons and color turns to blue Then same way to press number 20 30 40 on the output buttons area shows as above picture SCENE Icon Total can save 24 scenes after press SCENCE it will show below interface ...

Страница 10: ...ne After the scenes saved successfully user also can choose the scene name to recall the previous saved switching status Such as users want to recall scene 6 only need to press number 6 and then press load Users also can preview the scene switching status by both side windows next to the numbers SETUP Icon Users can change the name of Scene input and output here After changing the default settings...

Страница 11: ...11 Then change to the needed names Users also can change all the 24 scenes name together or one by one and then to press the save button as below ...

Страница 12: ...name of Input and output press the Input or Output icons showing as below After users changed the names and when back to the SWITCH and SCENE interface users can see the names have been well changed showing as below ...

Страница 13: ... help information as so on Unlock All the equipment have been locked users need to unlock the equipment if need to change the default settings First press Unlock button and enter the default password 12345678 and press Enter to unlock the equipment After unlocked the equipment users can change the names of the scene inputs outputs IP address and so on ...

Страница 14: ... status Press any input number then press this button to close the switching status Switch one to one Press this button to realize one to one switching status Close all the switching status Press this button to close all the switching status Save scene Press this button will turn to the scene save interface Recall scene Press this button will turn to the scene recall interface ...

Страница 15: ...ers need to make the sure RI 45 cable is workable and well connected with the control PC Second users need to change the IP address of the control PC at the same segment Third users only need to open the browser and type the matrix IP 192 168 0 80 and enter will show below interface Default user name and password are the same admin then click to Logo in Switch interface Users can switch and contro...

Страница 16: ...16 Caption Interface Users can change the name of scene inputs and outputs here and click to save after changes ...

Страница 17: ...17 ...

Страница 18: ...Reboot for modifying the matrix configuration IP address Login password Ethernet for changing IP address accordingly Administrator For changing the Login user name and password Multifunction Buttons For controlling the surrounding equipment ...

Страница 19: ...19 Multifunction buttons set up total we have 16 multifunction buttons at present We can rename the buttons Type the HEX code for each button and baud rate select Then click Save ...

Страница 20: ...ected the matrix with the WIFI router or local network Download the APP from the application store The steps and interfaces show as below Step 1 Make sure the matrix well connected with the router or local network and open the APP Step 2 Enter the IP address of the matrix Step 3 After log in successfully users can switch change the inputs and outputs name directly ...

Страница 21: ... to be one to one Eg 1 1 2 2 3 3 YXZ Y 1 2 3 4 Z 1 2 3 4 Switch Input Y to Output Z Eg 1X2 means switch Input 1 to output 2 YXZ Q W Y 1 2 3 4 Z 1 2 3 4 Q 1 2 3 4 W 1 2 3 4 Switch Input Y to Output Z Q W Eg 1X2 3 4 means switch Input 1 to Output 2 3 4 SaveY Y 1 2 3 4 Save current status to scene Y Eg Save2 means saving current status to Scene 2 RecallY Y 1 2 3 4 Recall the saved scene Y Eg Recall2 ...

Страница 22: ...rvice for 2 2 year following the date of purchase from the Company or its authorized distributors If the product does not work within the guaranteed warranty period the company will choose and pay for the repair of the defective product or component the delivery of the equivalent product or component to the user for replacement of the defective item or refund the payment which users have made The ...

Страница 23: ...puts Support HDCP2 2 4K60 Supports 3 5mm audio embedded 4K60 HDBaseT Support HDBaseT input with one HDMI loop out Distance up to 40 70m at 4K60 Work with 4K60 40M TX 4K60 Fiber Supports 4 Fiber Optic LC input Distance up to 2km at 4K60 with SM fiber cable Needs to work with FIBER HDV 2KT 4K60 Output Cards 1080P Seamless Switching Cards MAV Support HDMI DVI VGA YPBPR CVBS LR input Support HDCP 1080...

Страница 24: ...r Optic Rx Note All the above cards can work with TOUCH MANAGER 800 1600 BUT we suggest to use only 1080P or 4K60 cards on one chassis instead of mixing use 1080P and 4K60 cards together Attachment B DIP Switches Operation Instruction 4K60 seamless switching cards 1080P seamless switching cards ...

Страница 25: ...25 ...

Отзывы: