Function of the Buttons
1) Power on and off button.
To turn the TESTER on or off, keep the button pressed for 5 seconds.
2) Group of navigation buttons of the TESTER.
a) "DOWN" button by pressing this button the pages are scrolled downwards. (indication 6)
b) "ENTER" button Pressing the button on page 1 you access:
1) Model verification of the interrogated device
2) Matriculation number
3) Week and year of construction
4) Estimated residual working days
5) Ignition cycles
6) Detected alarms
7) Corrections made
The "ENTER" button on page 3 "PRINT", serves to confirm the start of printing
The "ENTER" button, on page 4 "TAR 175", is used to modify the TAR according to the needs, pressing it will note
the blinking of the writing, and pressing "UP" or "DOWN" increases or decreases the data.
The "ENTER" button on page 5 "NEW" is used to reset the device to the factory data by resetting the counters
The "ENTER" button on page 6 "SAVE" is used to save permanently edited data
c) "UP" button by pressing this button the pages are scrolled upwards. (see indication 6)
Checking the status of the battery.
Pressing the "UP" and "DOWN" buttons at the same time, the message BAT appears on the display followed by three
segments; Segments full, charged battery, empty segments empty battery.
DISPLAY
The display used on the TESTER is of the alphanumeric type and is used to display the following information:
3) "LEL" unit of measurement for explosive gas; "ppm" for the toxic gas, the exchange takes place automatically
according to the type of probe.
4) Percentage reading, indicates the quantity of gas lost in the environment.
N.B. The word "FAULT" replaces the reading of the percentage of gas in case of probe failure.
5) Sign of "%" lights up only when explosive gas is read.
6) Reading page number; The tester contains 1 to 7 pages, depending on the model.
7) "ASTERISK with a line" icon lights up when the tester is not connected to the probe in question.
8) Clock icon, indicates that the probe in question is in the "WARMUP" wait state.
9) "IR" transmission element given to the tamper.
10) "USB" port TS1008 connection with equipment to be examined
Edit
Enter
TS1008
Sensor
Analyzer
LEL 20
*
%
2
UP Down
1
3
5
6 5
9
Print IR
1
2
7
Edit
Enter
TS1008
Sensor
Analyzer
LEL 20
*
10
3
4
5
6
%
2
UP Down
8
Page 4
Components and commands