BEINAT SGM600 Скачать руководство пользователя страница 1

    Belonging   to

Indispensabile instrument for the annual check of the probes

Instrument  of  testing  TS1008
To facilitate  the reading of the functional parameters of  the probe as well
as  the  control  of  annual  operating,  the  BEINAT  S.r.l.  has  built  a  new
portable  tester  TS1008.
The tester allows to read all the data in the memory of the probes eand by
serial transmission, it prints the ticket that confirms the testing data.

The SGM600is born from the elegance and prestige that has always distinguished  BEINAT S.r.l. and from the home
fitness  concept.
The  probe is a Catalytic gas detection unit with IP66 protection that, together with one of BE INAT’s industrial
type Control Units, detects the presence of esplosive gas such as Methane, LPG, Hydrogen, and other types of
gas.
The probe is managed by a microprocessor which not only supplies an alarm signal to the control unit connected
to it, but  also allows execution of a self-diagnosis and therefore an AUTOMATIC  CALIBRATION,

 

in order to always

have the maximum detection accuracy.
The self-calibration means the probe adapts in harsh and variable temperature environments, avoiding false alarms
due to anomalous events.
The probe has a 0 ÷ 20 % LEL linear output conforming to the 4 ÷ 20mA standard, for which can be connected
with one of BEINAT's industrial control units.
The important innovation of this probe is:
The possibility to substitute the sensor at the end of the operating cycle or fault by the technician without having
to send to BEINAT Srl.

CONFORMITY

Installation and user
guide

Important: Assembly / maintenance of the appliance must be carried out by qualified personnel and in
accordance with applicable laws and regulations.
The manufacturer assumes no responsibility for the use of products that have to comply with particular
environmental and / or installation standards.

Important note
Before connecting the equipment, it is recommended that you read the instruction manual carefully and
keep it for future reference. It is also recommended to perform the electrical connections correctly as
per enclosed drawings, observing the instructions and the Standards.
N.B. Refer to the documentation in all cases where the symbol is on the side

EN 50194
EN 50270

Compliant  EN 60079-29-1

Installation  EN 60079-29-2

Reports issued by  TUV Italia

Channel:  Beinat  gas  solutions

Electric connections also available on

Conventional Gas Sensor SGM600

V. R0

Содержание SGM600

Страница 1: ...mperature environments avoiding false alarms due to anomalous events The probe has a 0 20 LEL linear output conforming to the 4 20mA standard for which can be connected with one of BEINAT s industrial control units The important innovation of this probe is The possibility to substitute the sensor at the end of the operating cycle or fault by the technician without having to send to BEINAT Srl CONF...

Страница 2: ...ECTATIONS The installation of the SGM600 Sensor its ordinary and extraordinary maintenance every six months and its out of service removal at the end of the functional life guaranteed by the manufacturer must be carried out by authorized or specialized personnel Do not allow it to become wet The control unit can be seriously damaged as it is not waterproof either when immersed in water or exposed ...

Страница 3: ... IP42 1 1 YES NO BX180 unit 1 zone Omega bar DIN 1 IP20 1 1 YES NO BX280 unit 1 zone Omega bar DIN 2 IP20 1 1 YES NO BX449F unit 1 zone Omega bar DIN 4 IP20 1 1 YES NO BX308 unit 1 zone Omega bar DIN 8 IP20 1 1 YES YES BX308 Box unit 1 zone Wall 8 IP65 1 1 YES YES BX316 unit 2 zones Barra Omega 16 IP20 1 2 YES YES BX316 Box unit 2 zones Wall 16 IP65 1 2 YES YES TAKITJ8 Data Collector Wall 8 IP65 M...

Страница 4: ...ethane Hydrogen Ammonia Acetylene The probe should not be placed near the appliances to be controlled boilers burners industrial kitchens etc but on the opposite wall The probe should not be affected by smoke vapour etc as they could distort their measurement It must be placed away from sources of heat suction fans ventilation fans Positioning of the Sensor Detectiondiagrams data 30 cm Heavy gases...

Страница 5: ...ons 1 2 3 4 5 6 7 1 2 3 4 5 6 7 1 2 3 4 5 6 7 ON 1 2 3 4 5 6 K1 K2 K3 Connettore a innesto montato su sonda Led ON connection USB port Selec operation range FUNCTIONING OF LED The integrated LED on the sonde has a threefold function 1 Green LED Normal operation In waiting phase the LED flashes 2 Red LED State of alarm The frequency of light changes according to the percentage of gas monitored 3 Le...

Страница 6: ...at the wire isolation sheath has not been pinched Check the voltage at the terminals 1 2 It must be higher than 10 80 Vdc and lesser than 26 4 Vdc Check that the connector of the sensor is correctly inserted If it s connected to control unit Check the voltage at the terminals 2 3 It must be from a minimum of 0 8 Vdc to a maximum of 1 1 Vdc Remark If the probes are connected to the control units BX...

Страница 7: ... a sufficient concentration to activate the general alarm Warning If you have the following symptoms vomiting sleepiness or else go to the closest first aid station and inform the operators that you could have been poisoned by Carbon Monoxide or by an excess or deficiency of oxygen NOTES The installation of the SGM600 probe its ordinary and extraordinary maintenance and its out of service removal ...

Страница 8: ...UIPMENT This symbol on the product or its packaging to indicates that this product shall not be treated as household waste Instead it shall be handed over to the applicable collection point for the recycling of electrical and electronic equipment such as for example sales points in case you buy a new and similar product local collection points waste collection center local recycling center etc By ...