BEIJING CAP HIGH TECHNOLOGY KUB100 Series Скачать руководство пользователя страница 6

Up arrow, use to select KUB menu upward.

Power indicator

Alarm indicator

Base function keys, it includes RANGE, GATES, GAIN, MODE and ECHO, the detail

info. refer to Table3.

Calibration function keys, it includes PROBE, CAL, ANGLE, PULSER and SETUP, the

detail info. refer to Table3.

Save function keys, it includes CHNL, WAVE, VIDEO, RESET and RESV, the detail info.

refer to Table3.

System function keys about the detector, it includes DISP, SCALE, ALARMS, SETUP

and INFO, the detail info. refer to Table3.

Function keys about the special function of the detector, it includes SCAN, WELD,

DIAM, CRACK and CSC, the detail info. refer to Table3.

Gate shortcuts key, the detail info about gate can be set directly by pressing

GATE

key.

Gain shortcuts key, the detail info about gain can be set directly by pressing

GAIN

key.

Channel shortcuts key, the detail info about channel can be checked directly by pressing

GAIN

key.

Angle shortcuts key, the detail info about angle can be set and calibrated directly by

pressing

ANGLE

key

Curve function key, DAC and AVG can be switched by pressing CURVE key.

Expand shortcuts key, the wave in the gate will expand automatically by pressing

EXPAND

key.

Color shortcuts key, you can directly set the color of the screen according to your
requirement by pressing

COLOR

key.

Parameter shortcuts key, you can enter into the parameter setting GUI to set each

parameter, it includes almost all parameters.

Standard shortcuts key, you can enter into the standard setting GUI to select the standard

according to your requirement.

Содержание KUB100 Series

Страница 1: ...aluation for the fields of aircraft railway traffic boiler pressure vessels etc Safety tips The detector is the device for industry ultrasonic non destructive testing can not use to medical testing To ensure safety operation the operator must have special knowledge of non destructive testing The detector must be used under allowed environment condition especially the detector can not be used under...

Страница 2: ...ound path gate Gain Multi grade adjustable has basic gain scan gain compensation gain Support gain locked and auto gain Alarm type Beep alarm and led alarm Alarm condition It can be chosen among wave in gate wave out gate wave in curve and wave out curve Data save The detector designs save shortcut key very convenient to operate The save as load play and delete can be carried out quickly Inspectio...

Страница 3: ... are shown in the Table 1 Table 1 Functions of KUB100 series MODEL KUB100 Series FUNCTION KUB100 KUB110 KUB120 KUB130 KUB140 SCREEN TFT TFT TFT TFT TFT DAC AVG STANDARD INSIDE GATE ALARM CURVE ALARM WAVE FREEZE CHANNEL 10 10 100 100 100 WAVE 100 100 1000 1000 1000 Video 5min 10 5min 20 5min 20 5min 20 60min 1 60min 1 AUTO CALIBRATION REJECT PEAK MEMORY ECHO ENVELOPE THICKNESS B SCAN COLOR B SCAN A...

Страница 4: ...VEL 10 PROBE DAMPING 100Ω 150Ω 200Ω 500Ω PROBE RPEATING FREQUENCY 10 1000Hz 10 2000Hz SENSITIVITY 62dB DEPTH 200mm FLAT BOTTOM HOLE Ф2 RESOLUTION 40dB 5P14 LINEARITY REJECT 0 80 DIGITAL REJECT VERTICAL LINEARITY ERROR 3 HORIZONTAL LINEARITY ERROR 0 1 DYNAMIC RANGE 32dB PULSE SQUARE WAVE PULSE ENERGY FIXED MULTI GRADES ADJUSTABLE PULSE WIDTH 50 300ns AUTO MATCH 50 1000ns ENVIROMENT TEMPERATURE 10 5...

Страница 5: ...porter 8 USB port 9 Reset and off port 10 Charging port 11 Receiving port 12 Receiving transmitting port 13 Protecting shell Keypad introduction The detector keypad is as shown in the Fig 2 Fig 2 function selecting keys Down arrow use to use to select KUB menu downward ENTER key to confirm each operation ...

Страница 6: ...te can be set directly by pressing GATE key Gain shortcuts key the detail info about gain can be set directly by pressing GAIN key Channel shortcuts key the detail info about channel can be checked directly by pressing GAIN key Angle shortcuts key the detail info about angle can be set and calibrated directly by pressing ANGLE key Curve function key DAC and AVG can be switched by pressing CURVE ke...

Страница 7: ...en by pressing these five keys Second part is the second row includes three basic operation buttons which are UP ENTER DOWN key different parameters at the right screen in the KUB menu can be switched by pressing UP and DOWN key press ENTER key to confirm operation and enter into the next step The third part is the area of function group and shortcuts Menu structure The menu structure of the KUB10...

Страница 8: ...PE ALM REF ALM REF P FREQ MODE LOGIC PULSER ENERGY RESET ALL CHNL SETUP STANDARD SETUP FLAW TYP SETUP AVG REF CRACK HEIGHT AUTOSNAP P WIDTH ALL WAVE FLAW D REF D PT A mm DETECT PRF ALL VDO FLAW L P SIZE PT B mm P DAMP RECALL SHUTDOWN DAC REF P FREQ GSTART mm ECHO RECTIFY SETUP THICK RESV INFO YY MM DD DISP DAC SHOW DISP AVG SHOW CSC O DIAM REJECT AUTO 80 HH MM TYPE TYPE I DIAM FILL PEAK MEM FW VER...

Отзывы: