Programmable I/O (PIO) NA-9379, Basic setting

 

KI00341

 

2014-10

 

 

12.3

 

Wiring diagram, PIO 

12.3.1

 

PIO NA-9379, RTB terminal block 

 
 
 

 

 

 

 

System Power: The power for starting up CPU 

 

Field Power: The power for input and output line 

 

NOTE! 

Do not use an incorrect voltage/frequency!  

The use of an incorrect supply voltage or frequency can cause severe damage to the component. 

 

12.3.2

 

PIO NA-9379, Pin description 

Communication between the Network adapter and the expansion module as well as system / field 

power supply of the bus modules is carried out via the internal bus. It is comprised of 6 data pin and 

2 field power pin. 

 

 
 
 
 
 
 
 
 
 
 

 

 

NOTE! 

Do not touch data and field power pins in order to avoid soiling and damage by ESD noise. 

 

 
 

Pin  

Signal Description  Signal Description 

Pin 

System Power 0V 

System Power 0V 

F.G 

FG (Frame Ground) 

Field Power 0V 

Field Power 0V 

Field Power 24V 

Field Power 24V 

No. 

Name 

Description 

System Vcc 

System supply voltage (5V dc) 

System GND 

System Ground 

Token Output 

Token output port of Processor module 

Serial Output 

Transmitter output port of Processor module 

Serial Input 

Receiver input port of Processor module 

Reserved 

Reserved for bypass Token 

Field GND 

Field Ground 

Field Vcc 

Field supply voltage (24Vdc) 

 

 

 

www.beijer.se

 

29 (35)

 

K

I_eng_130531.

dot

, 070221

 

Содержание NA-9379

Страница 1: ...e used for Programmable I O NA 9379 2 About this Start Up document This Start Up document should not be considered as a complete manual It is an aid to be able to start up a normal application quickly...

Страница 2: ...A 9379 KI00343 This document and other Start Up documents can be obtained from our homepage Please use the address manual beijer se for feedback on our Start Up documents 3 First step For best underst...

Страница 3: ...e 15 8 7 Setting Device Parameter and I O Mapping 16 9 Program example 17 9 1 New project 17 9 2 Add Global Variable and Persistent Variables 17 9 3 I O Mapping 19 9 4 Write program in PLC_PRG 20 9 5...

Страница 4: ...S485 F W update or Repair Modbus RTU Slave Protocol acts by each two independent ports 3 RUN STOP Switch RUN PLC program is running Monitoring the program and protocol in the CODESYS STOP PLC program...

Страница 5: ...oad using Firefox Minor Fault Blinking Red The unit has occurred recoverable fault in self testing EEPROM checksum fault Unrecoverable Fault Red The unit has occurred unrecoverable fault in self testi...

Страница 6: ...Status LED Status LED is To indicate Not supplied field power OFF Not supplied 24Vdc field power 5Vdc system power Supplied field power Green Supplied 24Vdc field power 5Vdc system power 5 2 6 Indicat...

Страница 7: ...P 6 1 IP setting default 6 2 Set the IP with BootP server Install IOGuidePro in Windows XP Run IOGuidePro and start BootP server from meny Tools Click Start Bootp and Power ON to PIO and the MAC addre...

Страница 8: ...have to power OFF ON Then the PIO take the new setting Note Changing the IP can be made in a different way such as Click on Start BootP Power on the PIO and Double click at the MAC address Write the n...

Страница 9: ...every computer 7 1 Add PIO NA 9379 to CODESYS Change Standard to Professional Install PIO and I O modules device description file to CODESYS Programmable IO_NA9379 devdesc xml and ST xxxx devdesc xml...

Страница 10: ...Programmable I O PIO NA 9379 Basic setting KI00341 2014 10 The file is installed under PLCs and the I O moduls under Miscellaneous www beijer se 10 35 KI_eng_130531 dot 070221...

Страница 11: ...8 1 Programming and configuration Start CODESYS Click File and Choose New project In Templates mark Standard project In Name write the name of the project In Location write the library to save the pro...

Страница 12: ...g KI00341 2014 10 8 2 How to add a POU Highlight the Application option in the Device window and right click Select Add Object and choose POU Customize the POU according to desired characteristics www...

Страница 13: ...the TaskConfiguration to make a Task Select Add Object and choose Task Configuration or Task Click Open a task named Task is automatically created 8 4 How to add a POU to a Task Connect the created PO...

Страница 14: ...Bus cycle task and Output handle at stop Double click at Device NA9379 and select PLC setting and set like picture Note When test of I O hardware wiring with an empty program or the PIO in STOP set l...

Страница 15: ...e Slot Slot option in the Device window and right click at the module place Empty Click at Plug Device mark the module and double click at module or Plug Device NOTE Select the module in order like th...

Страница 16: ...meter setting I O Module Mark the module and right click and then Edit Object or double click at module Setting value can be read in the manual FnIO_Configuration_Parameter_Memory_Register 8 7 2 I O M...

Страница 17: ..._Basic contains the program example from this StartUp document Can be downloaded from our homepage 9 1 New project Configure the project like 9 2 Add Global Variable and Persistent Variables The easie...

Страница 18: ...Programmable I O PIO NA 9379 Basic setting KI00341 2014 10 Persistent Variables www beijer se 18 35 KI_eng_130531 dot 070221...

Страница 19: ...Programmable I O PIO NA 9379 Basic setting KI00341 2014 10 9 3 I O Mapping Mapping the I O Result Do the same for all input output digital and analog www beijer se 19 35 KI_eng_130531 dot 070221...

Страница 20: ...rite program in PLC_PRG Rebuild the program If no Error go to next step View error warning and message with View Messages NOTE When Generate code there can be warning s It s only a warning The project...

Страница 21: ...he Communication setting options If no gateway present create one by selecting Add Gateway choose default value Highlight the gateway Press Scan network and wait until scanning is done All CODESYS dev...

Страница 22: ...load the project to the device TxB SoftControl which was selected above menu Online select Login The project will now be downloaded to the device the RUN led are flickering Set the PIO to RUN with the...

Страница 23: ...Programmable I O PIO NA 9379 Basic setting KI00341 2014 10 9 6 Monitor I O module Global variable www beijer se 23 35 KI_eng_130531 dot 070221...

Страница 24: ...Project Archive The best way to get all components from a CODESYS project is to make a Save Send Archive That will save and pack all files referenced by and used within the currently opened project in...

Страница 25: ...of object type which is assigned to an application There might be only ONE such list per application Highlight the Application entry in Devices Right click and select Add Object Choose Persistent Vari...

Страница 26: ...ock Operating IEC 60068 2 6 Vibration shock resistance Based on IEC 60068 2 6 Sine Vibration 10 25 Hz 0 5mm 50 150 Hz 5g 150 1000 Hz 2g Sweep Rate 1 Oct min 50 cycles Sine Vibration 10 25 Hz 0 03 g Hz...

Страница 27: ...Module 32 Slots Max Input Size 126 Words 252 Byte Max Output Size 126 Words 252 Byte Max Nodes Limited by Ethernet Specification Baud rate 10 100Mbps Auto negotiation Full Duplex Interface Connector...

Страница 28: ...cal 24Vdc Current for I O Module 1 5A 5Vdc Isolation System power to internal logic Non isolation System power I O driver Isolation RJ45 Isolated with transformator RS232 RS485 Non isolation Field Pow...

Страница 29: ...ternal bus It is comprised of 6 data pin and 2 field power pin NOTE Do not touch data and field power pins in order to avoid soiling and damage by ESD noise Pin Signal Description Signal Description P...

Страница 30: ...4 5 6 RD Receive 7 8 Case Shield Pin Signal Name Description 1 2 TXD RS232 TXD 3 RXD RS232 RXD 4 5 GND RS232 GND 6 D RS485 D 7 8 D RS485 D 9 Toggle Switch Status Module is Description UP RUN PLC Run D...

Страница 31: ...cause that is double width module 12 6 Inserting and Removing the Module As above figure in order to safeguard the FnIO module from jamming it should be fixed onto the DIN rail with locking level To d...

Страница 32: ...Timer Auxiliary Relay memory cell Data Memory 512 KBytes Retain Time 6 days IW0 IW639 640 word Input and Internal memory QW0 QW639 640 word Output and Internal memory MW0 MW639 640 word Internal memo...

Страница 33: ...ble I O PIO NA 9379 Basic setting KI00341 2014 10 12 11 Check Compiler PIO and Library version Check Compiler Version Check NA9379 PIO version Check Library version www beijer se 33 35 KI_eng_130531 d...

Страница 34: ...I O Module MOD LED is red Wrong address ID Occurrence critical error in firmware Contact Sales team and send module for repair I O LED turns off Failure of realization expansion Module None expansion...

Страница 35: ...ator resistor is not installed install terminator resistor Check location of terminator resistor Configuration of Node address Check duplication node address Configuration of Master Check configuratio...

Отзывы: