background image

Foreword

Installation manual for EXTER T150

Foreword

All EXTER operator panels are developed to satisfy the demands of
human-machine communication. Built-in functions such as displaying and
controlling text, dynamic indication, time channels, alarm and recipe handling
are included.
The operator panel works primarily in an object-oriented way, making it easy to
understand and use. Configuration is carried out on a PC using the configuration
tool. The project can then be transferred and stored in the operator panel itself.
Various types of automation equipment such PLCs, servos or drives can be
connected to the EXTER operator panels. In this manual, the term “the
controller” refers to the connected equipment.
This manual explains how to install the operator panel. Please refer to the
reference manual for further information.

Order no: MAEN775E

Copyright © 2014-11 Beijer Electronics AB. All rights reserved.

The information in this document is subject to change without notice and is provided as available at the

time of printing. Beijer Electronics AB reserves the right to change any information without updating this

publication. Beijer Electronics AB assumes no responsibility for any errors that may appear in this document.

Read the entire installation manual prior to installing and using this equipment. Only qualified personnel

may install, operate or repair this equipment. Beijer Electronics AB is not responsible for modified, altered

or renovated equipment. Because the equipment has a wide range of applications, users must acquire the

appropriate knowledge to use the equipment properly in their specific applications. Persons responsible

for the application and the equipment must themselves ensure that each application is in compliance with

all relevant requirements, standards and legislation in respect to configuration and safety. Only parts and

accessories manufactured according to specifications set by Beijer Electronics AB may be used.

BEIJER ELECTRONICS AB SHALL NOT BE LIABLE TO ANYONE
FOR ANY DIRECT, INDIRECT, SPECIAL, INCIDENTAL OR
CONSEQUENTIAL DAMAGES RESULTING FROM THE
INSTALLATION, USE OR REPAIR OF THIS EQUIPMENT, WHETHER
ARISING IN TORT, CONTRACT, OR OTHERWISE. BUYER'S SOLE
REMEDY SHALL BE THE REPAIR, REPLACEMENT, OR REFUND
OF PURCHASE PRICE, AND THE CHOICE OF THE APPLICABLE
REMEDY SHALL BE AT THE SOLE DISCRETION OF BEIJER
ELECTRONICS AB .

Beijer Electronics, MAEN775E

Содержание EXTER T150

Страница 1: ...EXTER T150 Installation Manual English MAEN775E 2014 11...

Страница 2: ...updating this publication Beijer Electronics AB assumes no responsibility for any errors that may appear in this document Read theentireinstallation manual prior to installing and using this equipment...

Страница 3: ...10 3 TechnicalData 11 4 ChemicalResistance 13 4 1 MetalCasing 13 4 2 Touch Screen and Overlay Material 13 4 2 1 Autotex F157 207 13 4 2 2 Touch Screen Surface 14 4 2 3 Touch Screen Protector 15 5 Ope...

Страница 4: ...sa powerful irritant Incase of skincontact wash immediately with plenty ofwater In case of eye contact holdthe eye open ush with plenty of water and get medical attention The gures in this manualserve...

Страница 5: ...This product contains a battery this must onlybe changedin an areaknown tobe non hazardous Replace the battery with aCR2450 battery Use of anothertype ofbattery maypresent a risk of re orexplosion Wa...

Страница 6: ...oweroutlet Peripheral equipment must be appropriate forthe application and location 1 4 During Use Keep the operatorpanel clean Emergency stopand othersafety functions may notbe controlled from the op...

Страница 7: ...0 inch 50 mm 2 0 inch 11 97 inch 15 67 inch 2 36 inch Caution The openings on the enclosure are for airconvection Do not cover these openings 2 2 Installation Process 1 Unpackand check the delivery If...

Страница 8: ...operator panelistobe situated draw along the outer sides ofthe holesandcutaccording to the markings 3 Secure the operator panel in position usingallthe fasteningholesand the provided brackets and scre...

Страница 9: ...rrors in communication may occur Ensure that the voltage and polarity of the powersource is correct Separate high voltage cables from signal and supply cables Shielded communication cables are recomme...

Страница 10: ...the Controller For information aboutthe cables to be used when connecting the operator panelto the controller please refer to the help le for thedriverin question 2 2 3 Other Connections and Periphera...

Страница 11: ...pact flash type I and II Real time clock 20 PPM error because of ambient temperature Total maximum error 1 minute month at 25 C Temperature coefficient 0 034 0 006 ppm C2 Real time clock battery CR245...

Страница 12: ...XTER T150 Relative humidity 5 85 non condensed Approvals and certifications Information is available on the web site www beijerelectronics com See section ChemicalResistance for more information Beije...

Страница 13: ...Hydrochloric acid 5 Nitric acid 10 Isopropyl alcohol Phosphoric acid 43 Na hypochlorite 10 Turpentine Note If exposure to any of the above chemicals is demanded itis recommended to first test the chem...

Страница 14: ...l Windex1 Cyclohexanol Persil powderin solution1 Wisk Diacetone alcohol Petroleum spirit1 1 Extremely faintglossingof the texture was noted Autotex withstands DIN 42 115 Part2 exposure of up to 1 hour...

Страница 15: ...een Protector For harsh environments and exposure tooutdoorconditions it isrecommended to use a protective lm toguardthe touch screenfromdamage These optional parts can be ordered from Beijer Electron...

Страница 16: ...Operator PanelDrawings 5 Operator Panel Drawings 5 1 Communication Ports RS 232 RS 422 RS 422 485 RS 485 Ethernet USB Beijer Electronics MAEN775E 16...

Страница 17: ...Operator PanelDrawings 5 2 EXTER T150 Outline Beijer Electronics MAEN775E 17...

Страница 18: ...aid between the panel s chassis and the closest groundingpoint on the door see 3 in drawingabove 3 Connect astrongbut shortgroundingbraid betweenthe doorand the device cabinet see 4 indrawingabove 4 T...

Страница 19: ...nithas its shield directly grounded or groundedviaa capacitor Note In many cases connecting the shielded Ethernet cabling to the chassis at both ends is inappropriate Hum or grounding loops canoccur U...

Страница 20: ...e shield to the ground via a 0 1 F 250 Vplastic capacitor Both ends are then connected tothe ground in terms ofHF but only connected to the ground at one end in terms ofLF thus avoidingthe 50 Hz groun...

Страница 21: ...a large program for controllingthe temperature in the device cabinet An enamel coated steel cabinethasaradiant heatvalue of 5 5 W m2 and degrees C Installinga fan inside the cabinetwill even out the...

Страница 22: ...LVaccording to EN 60950 protection against electric shock andUL 950 Note Here is an example that explains why a secure 24 V DC feed can be ruined by mixing 24 V relay contacts with 230 V AC relay cont...

Страница 23: ...SB memory stick keyboard or similardevice is plugged in If anumberofunitsare connectedthat have a0 Vand a groundconnection and these are connected to various groundingpoints there is a substantial ris...

Страница 24: ...ires may be onthe same levelor require pull up orpull downtoensure that no faultysignals are detected when the busisin restingmode all transmittersare disconnected 1 2 3 4 5 V 0 V 1 K 1 K 120 ohm 120...

Страница 25: ...Head office Beijer Electronics AB Box 426 201 24 Malm Sweden www beijerelectronics com 46 40 358600...

Отзывы: