Recording:

For mastering, using a stereo compressor such as the COMPOSER PRO-XL 

MDX2600 can be recommended. Use it to custom-tailor the dynamic 

characteristics of your signal to the dynamic range of the recording equipment 

you are using. The signal is in this case passed on from the compressor into 

the recorder.

PHONES

The PHONES control adjusts the volume of the headphones connected to the 

PHONS/CTRL connector. If you connect active monitors or an amplifier, use this 

connector to adjust the output signal level.

!

!

CAUTION!

◊ 

We would like to draw your attention to the fact that extreme volumes 
may damage your hearing and/or your headphones or loudspeakers. 
Turn the MAIN MIX faders and the PHONES control in the main section 
fully down before you switch on the unit. Always be careful to set the 
appropriate volume.

Fig. 2.13: PHONS/CTRL connector

PHONS/CTRL connector

You can connect headphones to this ¼" TRS connector. The connector can also 

be used for feeding active monitor loudspeakers (or an amplifier) in your control 

room. For this purpose, the signal  is taken directly before it is passed on to the 

main mix faders.

2.3.6  Level meter and level setting

Fig. 2.14: Level meter

POWER

The blue POWER LED indicates that the device is switched on.

+48 V

The red “+48 V” LED lights up when the phantom power supply is switched 

on. The phantom power supply is necessary for condenser microphones and is 

activated using the corresponding switch on the rear of the device.

◊ 

Connect microphones before you switch on the phantom power supply. 
Please do not connect microphones to the mixer (or the stagebox/
wallbox) while the phantom power supply is switched on. In addition, 
the monitor/PA loudspeakers should be muted before you activate the 
phantom power supply. After switching on, wait approx. one minute to 
allow for system stabilization.

LEVEL METER/CLIP

The high-precision level meter accurately displays the appropriate signal level. 

LEVEL SETTING:

When recording to a digital device, the recorder’s peak meter should not exceed 

0 dB. This is because, unlike analog recordings, slightly excessive levels can create 

unpleasant digital distortion.
When recording to an analog device, the VU meters of the recording machine 

should reach approx. +3 dB with low-frequency signals (e.g. kick drum). Due to 

their inertia VU meters tend to display too low a signal level at frequencies above 

1 kHz. This is why, for example, a Hi-Hat should only be driven as far as -10 dB. 

Snare drums should be driven to approx. 0 dB.

◊ 

The peak meters of your XENYX display the level virtually independent 
of frequency. A recording level of 0 dB is recommended for all 
signal types.

2.3.7  USB input/output

Fig. 2.15: USB input/output

The XENYX mixer line has built-in USB connectivity, allowing stereo signals to 

be sent to and from the mixer and a computer. The audio sent from the mixer to 

a computer is identical to the MAIN MIX. Audio being sent to the mixer from a 

computer can be routed to the main mix with the 2-TR/USB RTN fader. 
Connect the USB type B plug into the USB jack on the mixer, and the other end 

into a free USB port on your computer. There are no required drivers, but we 

recommend that PC users install the included ASIO driver. The driver can also be 

downloaded from behringer.com.

2.4  Graphic 7-band equalizer

Fig. 2.16: The graphic stereo equalizer

The graphic stereo equalizer allows you to tailor the sound to the room acoustics.

Содержание XENYX X1222 USB

Страница 1: ...User Manual X1222 Premium 16 Input 2 2 Bus Mixer with XENYX Mic Preamps Compressors British EQs 24 Bit Multi FX Processor and USB Audio Interface...

Страница 2: ...arm analog sound that is unrivalled With the addition of the latest digital technology these best in class consoles combine the advantages of both analog and digital technology Table of Contents Thank...

Страница 3: ...arlyatplugs conveniencereceptacles andthepointwheretheyexitfromtheapparatus 11 Useonlyattachments accessoriesspecifiedby themanufacturer 12 Useonlywiththe cart stand tripod bracket ortablespecifiedbyt...

Страница 4: ...mixing console fulfils three main functions Signal processing Preamplification Microphones convert sound waves into voltage that has to be amplified several fold then this voltage is turned into sound...

Страница 5: ...Contact Information European Contact Information Should your country not be listed please contact the distributor nearest you A list of distributors can be found in the support area of our website beh...

Страница 6: ...gain settings of 15 dB Fig 2 2 The equalizer of the input channels The upper HIGH and the lower band LOW are shelving filters that increase or decrease all frequencies above or below their cut off fre...

Страница 7: ...ls in which a mic input is present in the channel the GAIN control has two scales just like in the mono channels there is a 0 to 40 dB scale that shows the preamplification of the mic signal the 20 to...

Страница 8: ...put of your monitor power amp or an active monitor system here to make the monitor mix audible to the musicians on the stage The signal mix is created using the channels MON controls FX SEND The FX SE...

Страница 9: ...g DAT recorder or also a CD player They can also be used as stereo line input Alternatively the output signal of a second XENYX or BEHRINGER ULTRALINK PRO MX882 can also be connected If you connect a...

Страница 10: ...agebox wallbox while the phantom power supply is switched on In addition the monitor PA loudspeakers should be muted before you activate the phantom power supply After switching on wait approx one min...

Страница 11: ...rack Attention The POWER switch does not fully disconnect the unit from the mains Unplug the power cord completely when the unit is not used for prolonged periods of time PHANTOM The PHANTOM switch ac...

Страница 12: ...ck mount brackets to the mixing console you need to remove the screws holding the left and right side panels Use these screws to fasten the two brackets onto the console being careful to note that eac...

Страница 13: ...ircuitry Mic E I N 20 Hz 20 kHz 0 source resistance 134 dB 135 7 dB A weighted 50 source resistance 131 dB 133 5 dB A weighted 150 source resistance 129 dB 130 5 dB A weighted Frequency response 10 Hz...

Страница 14: ...Bu DSP Texas Instruments Converter 24 bit Sigma Delta 64 128 times oversampling Sampling rate 40 kHz USB Audio Stereo In Out Connector Type B Converter 16 bit Sample Rate 48 kHz Main Mix System Data N...

Страница 15: ...hat interference will not occur in a particular installation If this equipment does cause harmful interference to radio or television reception which can be determined by turning the equipment off and...

Страница 16: ...We Hear You...

Отзывы: