5. CLEANING THE REFLECTOR

s

Disconnect the spotlight from the mains and remove the lamp casing as described in chapter

2.1.

s

Remove the color frame (chapter 4), the protective mesh and lens (chapter 3.1), so that the

reflector is easily accessible.

s

Cleaning the reflector: Use oil-free compressed air or a soft, lint-free cotton cloth. Tenacious

stains can be removed by adding some mild soap water, however, don’t forget to remove all

soap water remnants as well!

s

Remount the spotlight (see chapters 2.1 and 3.2).

+

Never  clean  the  reflector  with  commercial  window  cleaners,  as  the  chemical

substances contained in these agents can damage the reflective coating!

+

Don’t use paper towels or other material with a rough surface to wipe the reflector

clean, so as to avoid scratches damaging the reflector surface.

6. SUSPENDED INSTALLATION

Use the mounting bracket 

 to attach your spotlight to a stand or truss. Always use steel screws

with a diameter of approx. 12 mm to fasten the spotlight. Your UP1000 must be secured with an

additional safety steel cable 

. Use the steel cable fixed to the spotlight casing (eyelet 

). Once

the spotlight has been adjusted, it must be secured in place with the locking screw 

.

7. SPECIFICATIONS

Power

575 W max. (220 V / 240 V)

Max. room temperature

Ta = 45°C

Max. temperature of exterior

surfaces

Tmax = 175°C

Dimensions (Height * Diameter)

approx. 11 3/4" (300 mm) * 9 1/4" (237 mm)

Weight

approx. 3.2 kg

BEHRINGER is constantly striving to maintain the highest professional standards. As a result of these efforts, modifications may be

made from time to time to existing products without further notice. Specifications and appearance may differ from those listed or shown.

7. SPECIFICATIONS

Содержание UP1000 Ultrapar

Страница 1: ...User s Manual Version 1 0 December 2000 www behringer com ENGLISH ULTRAPAR UP1000...

Страница 2: ...situated on a bed sofa rug or similar surface the same applies to truss mounted operation proper ventilation must always be ensured Heat The spotlight should be situated away from heat sources such a...

Страница 3: ...rding to their function The spotlight can be operated from a power supply of max 120 V 5 A or 240 V 2 5 A The mains frequency must be 50 60 Hz Please note that your ULTRAPAR spotlight must be grounded...

Страница 4: ...mounted in place The entire bottom side of the lamp socket must be in contact with the casing s Remount the casing and connect it to the grounding cable coming from the spotlight Fasten the thumb scre...

Страница 5: ...s with its rounded side towards the rear The lower edge of the lens must be located behind the projecting elements of the lens ring Inserting the lens with its rounded side towards the front does not...

Страница 6: ...flector clean so as to avoid scratches damaging the reflector surface 6 SUSPENDED INSTALLATION Use the mounting bracket to attach your spotlight to a stand or truss Always use steel screws with a diam...

Страница 7: ...pair work are expressly excluded from this warranty in particular if caused by improper handling of the product by the user This also applies to defects caused by normal wear and tear in particular of...

Отзывы: