background image

3

E

This symbol, wherever it appears, alerts

you to the presence of uninsulated

dangerous voltage inside the enclosure

- voltage that may be sufficient to con-

stitute a risk of shock.

This symbol, wherever it appears, alerts

you to important operating and mainte-

nance instructions in the accompanying

literature. Read the manual.

SAFETY INSTRUCTIONS

CAUTION: To reduce the risk of electrical shock, do not remove

the cover (or back). No user serviceable parts inside;

refer servicing to qualified personnel.

WARNING: To reduce the risk of fire or electrical shock, do not

expose this appliance to rain or moisture.

DETAILED SAFETY INSTRUCTIONS:

All the safety and operation instructions should be read before the appliance is operated.

Retain Instructions:

The safety and operating instructions should be retained for future reference.

Heed Warnings:

All warnings on the appliance and in the operating instructions should be adhered to.

Follow instructions:

All operation and user instructions should be followed.

Water and Moisture:

The appliance should not be used near water (e.g. near a bathtub, washbowl, kitchen sink, laundry tub, in a wet

basement, or near a swimming pool etc.).

Ventilation:

The appliance should be situated so that its location or position does not interfere with its proper ventilaton. For

example, the appliance should not be situated on a bed, sofa rug, or similar surface that may block the

ventilation openings: or placed in a built-in installation, such as a bookcase or cabinet that may impede the

flow of air through the ventilation openings.

Heat:

The appliance should be situated away from heat sources such as radiators, heat registers, stoves, or other

appliance (including amplifiers) that produce heat.

Power Source:

The appliance should be connected to a power supply only of the type described in the operating instructions

or as marked on the appliance.

Grounding or Polarization:

Precautions should be taken so that the grounding or polarization means of an appliance is not defeated.

Power-Cord Protection:

Power supply cords should be routed so that they are not likely to be walked on or pinched by items placed

upon or against them, paying particular attention to cords and plugs, convenience receptacles and the point

where they exit from the appliance.

Cleaning:

The appliance should be cleaned only as recommended by the manufacturer.

Non-use Periods:

The power cord of the appliance should be unplugged from the outlet when left unused for a long period of time.

Object and Liquid Entry:

Care should be taken so that objects do not fall and liquids are not spilled into the enclosure through openings.

Damage Requiring Service:

The appliance should be serviced by qualified service personnel when:

- The power supply cord or the plug has been damaged; or

- Objects have fallen, or liquid has been spilled into the appliance; or

- The appliance has been exposed to rain; or

- The appliance does not appear to operate normally or exhibits a marked change in performance; or

- The appliance has been dropped, or the enclosure damaged.

Servicing:

The user should not attempt to service the appliance beyond that is described in the Operating Instructions. All

other servicing should be referred to qualifield service personnel.

Содержание Promixer DX 500

Страница 1: ...1 E D PRO MIXER DX500 Version 1 0 July 1998 User s Manual Bedienungsanleitung www behringer de...

Страница 2: ...t PRO MIXER DX500 Type designation and if applicable Article No which refers to this declaration is in accordance with the following standards or standardized documents x EN 60065 x EN 61000 3 2 x EN...

Страница 3: ...air through the ventilation openings Heat The appliance should be situated away from heat sources such as radiators heat registers stoves or other appliance including amplifiers that produce heat Pow...

Страница 4: ...4 BLOCK DIAGRAM...

Страница 5: ...reative mixing s PFL switches with status LEDs on all channels s A Balance control allows you to blend between Main and PFL on the phones section s External effect facility with send and return s Addi...

Страница 6: ...he BEHRINGER family With your highly competent suggestions for new products you ve greatly contributed to shaping our company and making it successful In return we guarantee you uncompromising quality...

Страница 7: ...g 10 3 2 1 Quick way 10 3 2 2 Gain setting by using PFL 10 3 3 Equalizer 11 4 MASTER SECTION 11 4 1 Output 11 4 2 Cross fader 11 4 3 Transforming with Punch 11 4 4 Effects loop 12 4 5 Outputs 12 5 PFL...

Страница 8: ...peakers Check that there is no signal going through the DX500 when the amps are switched on in order to avoid any sudden volume surges Best turn down all output faders and rotary controls first This m...

Страница 9: ...rating limits of the op amps themselves thanks to our generous 30 W external power supply unit Please connect the PSU with the PRO MIXER DX500 PSU connector on the rear panel of your mixer and turn it...

Страница 10: ...and the sampler for creative DJ work or a mono DJ mic and two stereo music sources Only the phono and mic inputs are device specific being matched exactly to your cartridge or mic response 3 2 Gain s...

Страница 11: ...gended ULTRA HIGH QUALITY FADER When set fully to the left only Channel 2 is heard in the mix and vice versa We know how much you rely on the cross fader for mixing For this reason we have ensured tha...

Страница 12: ...with MAIN additionally being available on professional balanced XLR type connectors Level to these outputs is controlled by a pair of rotary controls marked MAIN OUT and ZONE OUT top right on the top...

Страница 13: ...depressed is in addition to being sent to the bargraph meters and headphones output sent to the input of the sampler In RECORD mode the sampler is primed to begin recording once the big START STOP key...

Страница 14: ...nd sleeve ground screen Phones 1 4 jack socket tip left signal ring right signal and sleeve ground screen Please ensure that only qualified persons install and operate the PRO MIXER DX500 During insta...

Страница 15: ...their cable and plug already assembled but if you have to do it yourself some time this is how It is also possible in a crisis situation to tap this signal for use as a parallel feed for a line level...

Страница 16: ...and bass intelligibility Expander see Noise Gate Fader linear potentiometer with logarithmic response Feedback howlround unstable circuit e g mic speaker input output where a signal is able to return...

Страница 17: ...or program for recording and playing back sounds e g tape hard disk Regeneration see Feedback Resonance fast feedback Reverb device or program for adding reverb Route signal path RPM Revolutions Per...

Страница 18: ...18 Transient a transitory extreme rise in signal level Trimpot variable gain potentiometer Varispeed control for varying playback speed Wet signal mix signal with effects added 8 GLOSSARY...

Страница 19: ...nch 0 dB max 10 dB gain Effect send Cinch 6 dB SAMPLER Sample frequency 16 kHz speed control at 100 Quantization 4 bit ADPCM POWER SUPPLY Mains Voltages USA Canada 120 V AC 60 Hz PSU MXUL 2 U K Austra...

Страница 20: ...tle the buyer to claim consequential damages In no event shall the liability of BEHRINGER INTERNA TIONAL exceed the invoiced value of the product 7 OTHER WARRANTY RIGHTS This warranty does not exclude...

Страница 21: ...DX500 REAR PANEL...

Страница 22: ...DX500 FRONT PANEL...

Отзывы: