background image

8

PRO MIXER DX052

These are the LINE inputs to connect a tape deck, CD or

MD player etc.
The 

GND

 connectors ground the turntables.

The  DX052  features  an  integrated  effects  loop  for  the

connection  of  an  external  effects  device/sampler.  The

MONITOR signal is taken at the 

SEND

 output and routed,

for  example,  to  a  reverb  processor.  Thus,  the  signal  at

the SEND connector is identical to the headphones signal.
The externally processed signal is added to the MASTER

output  signal  via  the 

RETURN 

connectors.  The  effect

signal volume may only be adjusted at the output control

of  the  effects  device  itself.

Fig. 3.2: PRO MIXER DXD052 rear panel connectors

The 

MASTER

 output is for connecting to an amplifier and

can be adjusted with the MASTER level control.

+

Always turn the power amps on last to avoid inrush

currents  that  can  easily  damage  your  speakers.

And,  to  avoid  sudden  and  unpleasant  surprises

for  your  ears,  make  sure  there  is  no  signal  at  the

DX052  before  turning  on  the  power  amps.  To  be

sure,  slide  all  the  faders  to  the  bottom  and  switch

all  controls  to  the  zero  position.

Using  the 

TAPE

  output  you  can  record  your  music  by

connecting  devices  such  as  tape  decks,  DAT  recorders

etc. Unlike the MASTER output, the output volume is fixed,

making it necessary for you to adjust the input level on the

recording  device.
The 

POWER 

switch  powers  the  DX052  on.  You  should

always make sure that the POWER switch is in the “Off”

position when initially connecting the unit to the mains.

+

Please  take  note:  Merely  switching  the  unit  off  does

not  mean  that  it  is  fully  disconnected  from  the

mains.  When  not  using  the  unit  for  prolonged

periods  of  time,  please  unplug  the  unit’s  power

cord  from  the  power  outlet.

FUSE HOLDER / VOLTAGE SETTING

. Before connecting

the unit to the mains, ensure that the voltage setting matches

your  local  voltage.  Blown  fuses  should  only  be  replaced

by a fuse of the same type and rating. On some units, the

fuses holder can be switched to one of two positions, i.e.

230 V and 120 V. Please note: should you desire to operate

the  unit  outside  Europe  at  120  V,  a  higher  fuse  rating  is

required.
This  is  the  connector  for  the  power  cable.  This  is  where

the  advantage  of  a  sophisticated  internal  power  supply

can be seen: the pulse behaviour of each amplifying circuit

is  mainly  determined  by  the  voltage  reserves  available.

Each mixing console is equipped with numerous operational

amplifiers (op amps) to process line level signals. Due to

limited output of their power supplies, many mixing consoles

show  signs  of  “stress”  when  subjected  to  heavy  loads.

But  not  your  DX052:  the  sound  is  always  clear  and

transparent.

+

To  disconnect  power  from  main,  pull  out  the  main

cord  plug.  When  installing  the  product,  ensure  that

the  plug  is  easily  accessible.  If  mounting  in  a  rack,

ensure  that  the  mains  can  be  easily  disconnected

by  a  plug  or  by  an  all-pole  disconnect  switch  on  or

near  the  rack.

SERIAL NUMBER

. Please take the time to complete and

return  the  warranty  card  within  14  days  of  the  date  of

purchase. 

Or, 

simply 

register 

online 

at

www.behringer.com.

4. SPECIFICATIONS

AUDIO INPUTS

Mic

40 dB Gain,

electronically balanced input stage

Phono 1 and 2

40 dB Gain, unbalanced inputs

Line 1 and 2

0 dB Gain, unbalanced inputs

Return

0 dB Gain, unbalanced input

AUDIO OUTPUTS

Master

max. +19 dBu @ +10 dB (Line in)

Tape

typ. 0 dBu

Send

typ. 0 dBu

Phones

max. 180 mW  @ 75 

 / 1% THD

EQUALIZER

Stereo  Low

+12 dB/-32 dB @ 50 Hz

Stereo High

+12 dB/-32 dB @ 10 kHz

Mic  Low

+12 dB/-12 dB @ 50 Hz

Mic High

+12 dB/-12 dB @ 10 kHz

GENERAL

Signal-to-noise ratio

> 87 dBu (Line)

Crosstalk

> 70 dB (Line)

Distortion (THD)

< 0,05%

Frequency  response 10 Hz - 55 kHz +0/-3 dB

POWER SUPPLY

Mains voltages

USA/Canada

120 V~, 60 Hz

Europe/U.K./Australia

230 V~, 50 Hz

Japan

100 V~, 50 - 60 Hz

General export model

120/230 V~, 50 - 60 Hz

Power  consumption

13 W

Fuse

100 - 120 V~: 

T  500 mA  H

200 - 240 V~: 

T  250 mA  H

Mains connection

Standard IEC receptacle

DIMENSIONS/WEIGHT

Dimensions (H x W x D) approx. 4 3/10" (109.2 mm)

x 10 2/5" (264 mm)

x 12 2/5" (315 mm)

Weight

approx. 2.3 kg (5 1/16 lbs)

BEHRINGER makes every effort to ensure the highest standard of quality. Necessary

modifications are carried out without notice. Thus, the specifications and design of the device

may differ from the information given in this manual.

4. SPECIFICATIONS

Содержание Pro Mixer DX052

Страница 1: ...PRO MIXER DX052 Version 1 0 March 2003 User s Manual ENGLISH...

Страница 2: ...amplifiers that produce heat 9 Do not defeat the safety purpose of the polarized or grounding type plug A polarized plug has two blades with one wider than the other A grounding type plug has two bla...

Страница 3: ...Professional crossfader reverse switch s Awesome adjustable XPQ stereo surround effect s 2 band kill EQ 32 dB gain and balance control per channel s PFL function with CH 1 CH 2 balance control s Prec...

Страница 4: ...d what a great feeling it is when everybody who has participated in such a project can be proud of what they ve achieved It is our philosophy to share our enjoyment with you because you are the most i...

Страница 5: ...the vicinity of a heater to avoid the risk of overheating Before plugging the unit into a power socket please make sure you have selected the correct voltage The fuse compartment near the power plug s...

Страница 6: ...uency range out of a music track The overall level also depends on the EQ setting Thus you should adjust the equalizer before setting the input gain with the TRIM control The input channels come with...

Страница 7: ...r sound The PAN ORAMA control determines the position of the microphone signal within the stereo image of the MASTER signal 2 3 MASTER and MONITOR section This is the MASTER level control to adjust th...

Страница 8: ...ire to operate the unit outside Europe at 120 V a higher fuse rating is required This is the connector for the power cable This is where the advantage of a sophisticated internal power supply can be s...

Страница 9: ...responsible for any cost resulting from such a modification adaptation 3 Free inspections and maintenance repair work are expressly excluded from this warranty in particular if caused by improper hand...

Отзывы: