background image

22

INTELLIGATE XR2000

5.4

Anticipated expansion

If you feed the audio signal directly into the KEY RETURN input and send the audio signal through a delay
before the audio input, the BEHRINGER INTELLIGATE can anticipate the need for gain change. With
experimentation, the effect can create a “zero” attack time at a given frequency. Additional delay beyond this
“zero” attack time, will produce a special sound effect, similar to the dynamic-envelope inversion you may
already be familar with from reverse tape playback.

Fig. 5.2: Anticipated expansion using the INTELLIGATE

5.5

Triggering additional sounds from a rhythm track

This technique is used to give a rhythm track more “punch”. For this purpose, the Expander section of the
INTELLIGATE is required. The bass guitar track is connected to the audio chain of the BEHRINGER
INTELLIGATE, whilst the bass drum is connected to the KEY RETURN input. By activating the KEY EXT
switch, the bass guitar is now triggered by the bass drum.

Another application allows the sound of the bass drum to be supported or extended by other instruments
(synthesizer etc.), where the bass drum is used to trigger a new sound, which is then mixed into the track.

Fig. 5.3: Triggering a keyboard sound using a bass drum

5. EXTERNAL SIDECHAIN APPLICATIONS

Содержание Intelligate XR2000

Страница 1: ...Version 1 2 January 2001 INTELLIGATE XR2000 www behringer com User s Manual ENGLISH...

Страница 2: ...w of air through the ventilation openings Heat The appliance should be situated away from heat sources such as radiators heat registers stoves or other appliances including amplifiers that produce hea...

Страница 3: ...ost important member of the BEHRINGER team With your highly competent suggestions for new products you ve greatly contributed to shaping our company and making it successful In return we guarantee you...

Страница 4: ...uation control in Gate mode V Independent hold release controls for any envelope shaping V Key listen facility for monitoring the filter section V High performance Class A VCA s V Ultra low noise 4580...

Страница 5: ...Controlling leakage in the studio 16 3 4 2 Reducing leakage in stage mics 17 3 4 3 Reducing feedback in stage mics 17 3 4 4 Noise reduction on effects paths 17 3 5 Using the INTELLIGATE to change the...

Страница 6: ...o fade noise out of complex programme material the unit would inadvertently create undesirable side effects To eliminate this problem one would use an additional expander which would create a continuo...

Страница 7: ...disable the ground connector of the unit or of the AC power cable As standard the BEHRINGER INTELLIGATE is installed with electronically servo balanced inputs and outputs The new circuit design featur...

Страница 8: ...the time taken for the gain to be reduced to a value set by the RANGE control When in the Ducker mode this control adjusts the rate of recovery to unity gain after the hold cycle is complete The cont...

Страница 9: ...ve channel is disabled When this function is active a visual indication will be provided by the switches LED 16 When activated the KEY EXT switch severes the connection between the audio input and the...

Страница 10: ...rve so that the signal continually fades Noice gates however can be seen as a special type of expander They normally work with a more exaggerated ratio and radically attenuate the signal if it falls b...

Страница 11: ...extremely quick attack time is necessary for very fast transients e g for handclaps or percussive instruments so that the expander does not loose the initial transients and affect the sound The new UT...

Страница 12: ...GATE The ratio curve characteristic automatically adapts itself dependent on programme material At lower ratios with reducing expansion the transition is gentle whereas higher ratios and increasing ex...

Страница 13: ...d right signals vary When the COUPLE switch is engaged the INTELLIGATE functions in stereo mode whereby the left channel takes over the control of both channels so that the control voltage in channel...

Страница 14: ...the function of each control is understood you will find your own applications 3 1 1 The gating function Gating is a so called high ratio expander function and is the simplest function of the BEHRING...

Страница 15: ...ort release time from affecting the natural decay and the additional ambient sound of the instrument For signals with long durations or signals with heavy ambience it is advantageous to choose long re...

Страница 16: ...uency selective expansion Sometimes it is necessary to prevent the expander from responding to low frequencies rumbles etc especially if a singer is moving the microphone around on a mic stand Besides...

Страница 17: ...The aim is to set up the expander and to position the group mics so that each strike on an instrument opens a specific mic and only that instrument is recorded whilst the other mics remain muted 3 4...

Страница 18: ...levels which can sometimes cause an otherwise normal and undistorted voice to sound very harsh shrill and sometimes unintelligible In order to reduce the problem associated with sibilance a ducker can...

Страница 19: ...vious chapter This will result in ducking of the selected frequencies and thus a decrease in the gain of the programme material 4 2 2 Suppressing instruments during recording Another function of the B...

Страница 20: ...ed to the KEY SEND output and the KEY RETURN input now receives the new control signal which is derived from an inserted effects processor 5 2 Using an equalizer in the sidechain path It is very commo...

Страница 21: ...c signal has reached its normal level 6 Adjust the RANGE control of channel 1 about mid position With this control you adjust the range of the voice over function We recommend a starting point of abou...

Страница 22: ...expansion using the INTELLIGATE 5 5 Triggering additional sounds from a rhythm track This technique is used to give a rhythm track more punch For this purpose the Expander section of the INTELLIGATE i...

Страница 23: ...ly to export models exclusively designed e g for 115 V operation Please use the enclosed power cord to connect the unit to the mains The cord complies with all applicable safety standards 6 2 Audio co...

Страница 24: ...DC de coupled unbalanced input Impedance 20 kOhms Max Input Level 20 dBu KEY OUTPUT Type DC de coupled unbalanced output Impedance 150 Ohms Max Output Level 20 dBu KEY FILTER SECTION Low Cut variable...

Страница 25: ...V 50 Hz General Export Model 100 120 V 200 240 V 50 60 Hz Power Consumption max 15 Watts Fuse 100 120 V T 320 mA H 200 240 V T 160 mA H Mains Connection Standard IEC receptacle PHYSICAL Dimensions ap...

Страница 26: ...days of receipt of the product at BEHRINGER 2 If the product needs to be modified or adapted in order to comply with applicable technical or safety standards on a national or local level in any countr...

Отзывы: