2. CONTROL ELEMENTS AND CONNECTIONS

Device ID Number:

You should only change ID number if you are using several NANOs and problems with recognizing the

correct unit occur during a SysEx dump.

+

Please keep in mind that SysEx dumps can only be received on the device ID number to

which they were sent!

System Exclusive Dump (SysEx):

By turning the VALUE 1 push encoder 

, you can select whether only the current preset (Single Dump) or

the entire 99 preset contents (All Dump) are sent as a SysEx dump. Pressing the push encoder once triggers

the dump.
To receive a SysEx dump, no adjustments on the unit whatsoever are necessary. If you send a single preset

to the B-CONTROL, the data is stored in temporary memory and has to be stored into a preset if you wish to

store it permanently (see 

 preset store function).

+

ATTENTION: If you send an “All Dump” to the B-CONTROL, the entire contents of its memory

are immediately overwritten! You will not be asked to confirm your choice, and there is no

memory safeguard function!

s

To cancel a SysEx dump, press the EXIT button.

MIDI Merge:

With this function, incoming MIDI data are mixed with the BCN44 data at MIDI Out (see fig. 2.2).

Fig. 2.2: Routing with MIDI merge

To activate MIDI merge, turn the push encoder 

. The 4 push encoders labeled 

 through 

 are

used for sending MIDI data. These push encoders have two functions (turn and press), to which different

MIDI commands can be assigned.

When in EDIT mode, use 

CHANNEL 

to change the values set in tables 6.3 and 6.4.

When in EDIT mode, use 

PARAMETER

 to change the values set in tables 6.3 and 6.4.

When in EDIT mode, use 

VALUE 1

 to change the values set in tables 6.3 and 6.4.

When in EDIT mode, use 

VALUE 2

 to change the values set in tables 6.3 and 6.4. Each of the 4

buttons labeled 

 through 

 sends the programmed MIDI command.

+

Note on using the buttons while in EDIT mode: Keep the button pressed and use the push

encoder located above it to select a value. After that, release the button.

The 

TYPE

 button selects the type of MIDI data sent in EDIT mode.

The 

MODE

 button selects the “Controller Mode” for the selected MIDI data type function in EDIT mode

(see table 6.3 and 6.4).

Downloaded from 

ManualsNet.com

 search engine

Содержание B-Control NANO BCN44

Страница 1: ...User s manual Version 1 0 March 2005 B CONTROL NANO BCN44 Downloaded from ManualsNet com search engine...

Страница 2: ...ed plug has two blades with one wider than the other A grounding type plug has two blades and a third grounding prong The wide blade or the third prong are provided for your safety If the provided plu...

Страница 3: ...AND CONNECTIONS 5 2 1 Additional functions 9 2 1 1 Snapshot Send 9 2 1 2 Single Preset Dump 9 2 1 3 Storing received Single Preset Dumps 9 3 APPLICATION EXAMPLES 9 3 1 Software Controller 9 3 2 Hardw...

Страница 4: ...nsure optimal protection during transportation we recommend using a carrying case Always use the original packaging to avoid damage due to storage or shipment Never let unsupervised children play with...

Страница 5: ...re pressed s After the reset is complete the unit automatically resumes normal operation and the current preset is shown in the display When powering up the unit the four digit LED display shows the c...

Страница 6: ...the selected control element and is shown in the display e g E ncoder 3 LED is lit or b utton 1 LED blinks To exit the EDIT mode press the EDIT EXIT button The unit switches back into normal operatin...

Страница 7: ...mory safeguard function s To cancel a SysEx dump press the EXIT button MIDI Merge With this function incoming MIDI data are mixed with the BCN44 data at MIDI Out see fig 2 2 Fig 2 2 Routing with MIDI...

Страница 8: ...f position whenever you establish a connection to the mains Please keep in mind The POWER switch does not entirely separate the unit from the mains Please disconnect the power cord from the mains if y...

Страница 9: ...uding the current control element assignment are being sent This function lets you easily archive specific presets or swap them with other B CONTROL users 2 1 3 Storing received Single Preset Dumps Th...

Страница 10: ...es using the MIDI THRU connector on the sound module thus receiving the looped through MIDI control data of the BCN44 The key data note pitch bend etc are mixed with the controller data of the BCN44 p...

Страница 11: ...individual control elements controls buttons etc on your B CONTROL to CC messages Because both buttons and knobs can be used you can control controller values either statically or dynamically all in r...

Страница 12: ...le 6 1 in the appendix ch 6 Pitch Bend The Pitch Bend wheel on a keyboard lets you bend the pitch of a tone The Pitch Bend functions has its own allocation in the MIDI format and can be assigned to a...

Страница 13: ...sion GOOd is shown in the display otherwise bAd is shown in the display if false defective or excessively long data was sent s To leave or cancel the LEARN function press the EDIT EXIT button s Store...

Страница 14: ...Table 6 1 MIDI note number assignment 6 3DUDPHWHU 7 S LVSOD Filter Cutoff NRPN CUTF Filter Resonance NRPN RESO Vibrato Rate NRPN RATE Vibrato Depth NRPN DEPT Vibrato Delay NRPN DLY EG Attack NRPN ATC...

Страница 15: ...ncrement mode is selected positive and negative value range 0 to 127 127 is selectable with VALUE 1 VALUE 2 has no function in this mode TYPE MODE and DISPLAY buttons Keep the respective button presse...

Страница 16: ...rn function of push encoders in EDIT mode TYPE MODE and DISPLAY buttons Keep the respective button pressed and use the push encoder located above it to dial up a value After that release the button 6...

Страница 17: ...11 undefined 16 General Purpose 1 48 General Purpose 1 LSB 80 General Purpose 5 112 Controller 112 undefined 17 General Purpose 2 49 General Purpose 2 LSB 81 General Purpose 6 113 Controller 113 undef...

Страница 18: ...not be accepted 5 WARRANTY REGULATIONS 1 Warranty services will be furnished only if the product is accompanied by a copy of the original retail dealer s invoice Any product deemed eligible for repair...

Страница 19: ...f any kind for any purpose without the express written permission of BEHRINGER Spezielle Studiotechnik GmbH BEHRINGER is a registered trademark ALL RIGHTS RESERVED 2005 BEHRINGER International GmbH BE...

Отзывы: